Product Overview
-
HI83300
-
Multiparameter Photometer
-
Multiparameter water quality rapid analyzer, uniquely combining electrochemical and colorimetric methods, with a built-in rechargeable system, nearly 60 water quality measurement items, wide application range, easy operation and portability, suitable not only for laboratory use but also for rapid water quality measurement on site or in the field.
-
Clever combination of electrochemical measurement method and colorimetric method: can connect pH electrode to measure acidity pH value;
-
Built-in rechargeable lithium battery and power adapter, meeting the needs of rapid measurement in the laboratory and in the field;
-
Good quality optical path system, scientifically designed measurement cell, effectively avoiding light interference, ensuring measurement accuracy and reliability;
-
USB data interface, storage of 1000 measurement data, convenient for data management and analysis;
-
LCD backlight function, convenient for viewing in different environments, on-screen help information, step-by-step guidance to complete various operations, simple and user-friendly.
| Parameter | Measuring range | Resolution | Accuracy | Optional reagent | ▲▼ key to switch items |
| Alkalinity |
0 to 500 mg/L |
1 mg/L | Reading ±5% ±5mg/L @25 ℃ | HI775-26 | --- |
| Alkalinity, seawater | 0 to 300 mg/L (as CaCO3) |
1 mg/L | Reading ±5% ±5mg/L @25 ℃ | HI775-26 | Softness (DKH) and carbonate hardness (KH) |
| Aluminum |
0.00 to 1.00 mg/L (as AI3) |
0.01 mg/L |
Reading ±4% ±0.04mg/L @25 ℃ |
HI93712-01 HI93712-03 |
Aluminum chloride [aluminum oxide] (AI2O3) |
| Ammonia low range |
0.00 to 3.00 mg/L (as NH3-N)) |
0.01 mg/L |
Reading ±4% ±0.04mg/L @25 ℃ |
HI93700-01 HI93700-03 |
NH3 and NH4+ |
| Ammonia medium range |
0.00 to 10.00 mg/L (as NH3-N)) |
0.01 mg/L |
Reading ±5% ±0.05mg/L @25 ℃ |
HI93715-01 HI93715-03 |
NH3 and NH4+ |
| Ammonia high range |
0.0 to 100.0 mg/L (as NH3-N)) |
0.1 mg/L | Reading ±5% ±0.5mg/L @25 ℃ |
HI93733-01 HI93733-03 |
NH3 and NH4+ |
| Bromine |
0.00 to 8.00 mg/L (as Br2) |
0.01 mg/L |
Reading ±3% ±0.08mg/L @25 ℃ |
HI93716-01 HI93716-03 |
--- |
| Calcium |
0 to 400 mg/L (as Ca2+) |
1 mg/L | Reading ±6% @25 ℃ |
HI93521-01 HI93521-03 |
--- |
| Calcium, seawater |
200 to 600 mg/L (as Ca2+) |
1 mg/L | Reading ±6% @25 ℃ | HI758-26 | --- |
| Chloride |
0.0 to 20.0 mg/L (as CI-) |
0.1 mg/L |
Reading ±6% ±0.5mg/L @25 ℃ |
HI93753-01 HI93753-03 |
--- |
| Chlorine dioxide |
0.00 to 2.00 mg/L (as CIO2) |
0.01 mg/L |
Reading ±5% ±0.10mg/L @25 ℃ |
HI93738-01 HI93738-03 |
--- |
| Free chlorine |
0.00 to 5.00 mg/L (as CI2) |
0.01 mg/L |
Reading ±3% ±0.03mg/L @25 ℃ |
HI93701-01 HI93701-03 HI93701-F |
--- |
| Free chlorine ultra-low range |
0.000 to 0.500 mg/L (as CI2) |
0.001 mg/L |
Reading ±3% ±0.020 mg/L @25 ℃ |
HI93762-01 HI93762-03 |
--- |
| Total chlorine |
0.00 to 5.00 mg/L |
0.01 mg/L |
Reading ±3% ±0.03 mg/L @25 ℃ |
HI93711-01 HI93711-03 HI93701-T |
--- |
| Total chlorine ultra-low range |
0.000 to 0.500 mg/L (as CI2) |
0.001 mg/L | Reading ±3% ±0.020 mg/L
@25 ℃ |
HI93761-01 HI93761-03 |
--- |
| Total chlorine ultra-high range |
0 to 500 mg/L (as CI2) |
1 mg/L | Reading ±3% ±3 mg/L
@25 ℃ |
HI93771-01 HI93771-03 |
--- |
| Hexavalent chromium low range |
0 to 300 μg/L (as Cr6+) |
1 μg/L | Reading ±4% ±1 μg/L
@25 ℃ |
HI93749-01 HI93749-03 |
Chromate (CrO42-) and dichromate (CrO72-) |
| Hexavalent chromium high range |
0 to 1000 μg/L (as Cr6+) |
1 μg/L | Reading ±4% ±5 μg/L
@25 ℃ |
HI93723-01 HI93723-03 |
Chromate (CrO42-) and dichromate (CrO72-) |
| Color |
0 to 500 PCU (platinum-cobalt units) |
1 PCU | Reading ±5% ±10 PCU
@25 ℃ |
--- | --- |
| Copper low range |
0.000 to 1.500 mg/L (as Cu2+) |
0.001mg/L | Reading ±5% ±0.010 mg/L
@25 ℃ |
HI93747-01 HI93747-03 |
--- |
| Copper high range |
0.00 to 5.00 mg/L (as Cu2+) |
0.01mg/L | Reading ±4% ±0.02 mg/L
@25 ℃ |
HI93702-01 HI93702-03 |
--- |
| Cyanuric acid |
0 to 80 mg/L (as CYA) |
1 mg/L | Reading ±15% ±1 mg/L
@25 ℃ |
HI93722-01 HI93722-03 |
--- |
| Fluoride low range |
0.00 to 2.00 mg/L (as F-) |
0.01 mg/L | Reading ±3% ±0.03 mg/L
@25 ℃ |
HI93729-01 HI93729-03 |
--- |
| Fluoride high range |
0.0 to 20.0 mg/L (as F-) |
0.1 mg/L | Reading ±3% ±0.5 mg/L
@25 ℃ |
HI93739-01 HI93739-03 |
--- |
| Hardness, calcium |
0.00 to 2.70 mg/L (as CaCO3) |
0.01 mg/L | Reading ±5% ±0.11 mg/L
@25 ℃ |
HI93720-01 HI93720-03 |
French degrees (°FH), German degrees (°DH), English degrees (°EH) |
| Hardness, magnesium |
0.00 to 2.00 mg/L (ppm) (as CaCO3) |
0.01 mg/L | Reading ±5% ±0.11 mg/L
@25 ℃ |
HI93719-01 HI93719-03 |
French degrees (°FH), German degrees (°DH), English degrees (°EH) |
| Total hardness, low range |
0 to 250 mg/L (as CaCO3) |
1 mg/L | Reading ±4% ±5 mg/L
@25 ℃ |
HI93735-00 | French degrees (°FH), German degrees (°DH), English degrees (°EH) |
| Total hardness, medium range |
200 to 500 mg/L (as CaCO3) |
1 mg/L | Reading ±3% ±7 mg/L
@25 ℃ |
HI93735-01 | French degrees (°FH), German degrees (°DH), English degrees (°EH) |
| Total hardness, high range |
400 to 750 mg/L (as CaCO3) |
1 mg/L | Reading ±2% ±10 mg/L
@25 ℃ |
HI93735-02 | French degrees (°FH), German degrees (°DH), English degrees (°EH) |
| Hydrazine |
0 to 400 μg/L (as N2H4) |
1μg/L | Full range±4%, @25 ℃ |
HI93704-01 HI93704-03 |
--- |
| Iodine |
0.0 to 12.5 mg/L (as I2) |
0.1 mg/L |
Reading ±5% ±0.1 mg/L @25 ℃ |
HI93718-01 HI93718-03 |
--- |
| Iron low range |
0.000 to 1.600 mg/L(as Fe) |
1 μg/L |
Reading ±8% ±0.010 mg/L @25 ℃ |
HI93746-01 HI93746-03 |
--- |
| Iron high range |
0.00 to 5.00 mg/L (as Fe) |
0.01 mg/L |
Reading ±2% ±0.04 mg/L @25 ℃ |
HI93721-01 HI93721-03 |
--- |
| Magnesium |
0 to 150 mg/L (as Mg2+) |
1 mg/L |
Reading ±3% ±5 mg/L @25 ℃ |
HI93520-01 HI93520-03 |
--- |
| Manganese low range |
0 to 300 μg/L (as Mn) |
1 μg/L |
Reading ±3% ±10 μg/L @25 ℃ |
HI93748-01 HI93748-03 |
Potassium permanganate (KMnO4) and potassium permanganate (MnO4) |
| Manganese high range |
0.0 to 20.0 mg/L (as Mn) |
0.01 mg/L |
Reading ±3% ±0.2 mg/L @25 ℃ |
HI93709-01 HI93709-03 |
Potassium permanganate (KMnO4) and potassium permanganate (MnO4) |
| Molybdenum |
0.0 to 40.0 mg/L (as Mo6+) |
0.1 mg/L |
Reading ±5% ±0.3 mg/L @25 ℃ |
HI93730-01 HI93730-03 |
Molybdic acid (MoO42-) and sodium molybdate (Na2MoO4) |
| Nickel low range |
0.000 to 1.000 mg/L(as Ni) |
0.001 mg/L |
Reading ±7% ±0.010 mg/L @25 ℃ |
HI93740-01 HI93740-03 |
--- |
| Nickel high range |
0.00 to 7.00 g/L (as Ni) |
0.01 g/L |
Reading ±4% ±0.07 g/L @25 ℃ |
HI93726-01 HI93726-03 |
--- |
| Nitrate |
0.0 to 30.0 mg/L (as NO3-N) |
0.1 mg/L |
Reading ±10% ±0.5 g/L @25 ℃ |
HI93728-01 HI93728-03 |
Nitrate (NO3) |
| Nitrite ultra-low range, seawater |
0 to 200 μg/L (as NO3-N) |
1 μg/L |
Reading ±4% ±10 μg/L @25 ℃ |
HI764-25 | Nitrite (NO2) and sodium nitrite (NaNO2) |
| Nitrite low range |
0 to 600 μg/L (as NO3-N) |
1 μg/L |
Reading ±4% ±20 μg/L @25 ℃ |
HI93707-01 HI93707-03 |
Nitrite (NO2) and sodium nitrite (NaNO2) |
| Nitrite high range |
0 to 150 μg/L (as NO3-N) |
1 mg/L |
Reading ±4% ±4 mg/L @25 ℃ |
HI93708-01 HI93708-03 |
Nitrite (NO2) and sodium nitrite (NaNO2) |
| Dissolved oxygen |
0.0 to 10.0 mg/L (as O2) |
0.1 mg/L |
Reading ±3% ±0.4 mg/L @25 ℃ |
HI93732-01 HI93732-03 |
--- |
| Oxygen Scavenger |
0.00 to 1.50mg/L (as Carbohydrazide) |
0.01 mg/L |
Reading ±3% ±0.02 mg/L @25 ℃ |
HI93773-01 HI93773-03 |
--- |
| Oxygen Scavenger |
0 to 1000 μg/L (as DEHA) |
1 μg/L |
Reading ±5% ±5 μg/L @25 ℃ |
HI93773-01 HI93773-03 |
--- |
| Oxygen Scavenger |
0.00 to 2.50 mg/L (as Hydroquinone) |
0.01 mg/L |
Reading ±3% ±0.04 mg/L @25 ℃ |
HI93773-01 HI93773-03 |
--- |
| Oxygen Scavenger |
0.00 to 4.50 mg/L (as lso-ascorbicacid) |
0.01 mg/L |
Reading ±3% ±0.03 mg/L @25 ℃ |
HI93773-01 HI93773-03 |
--- |
| Ozone |
0.00 to 2.00 mg/L (as O3) |
0.01 mg/L |
Reading ±3% ±0.02 mg/L @25 ℃ |
HI93757-01 HI93757-03 |
--- |
| pH | 6.5 to 8.5 pH | 0.1 pH |
Reading ±0.1 pH@25 ℃ |
HI93710-01 HI93710-03 |
--- |
|
Phosphate Ultra-low range, seawater |
0 to 200 μg/L (as P) |
1 μg/L |
Reading ±5% ±5 μg/L @25 ℃ |
HI736-25 | Phosphorus (P) and phosphorus pentoxide (P2O5) |
|
PhosphateLow range |
0.00 to 2.50 mg/L (ppm) (as PO43-) |
0.01 mg/L |
Reading ±4% ±0.04 mg/L @25 ℃ |
HI93713-01 HI93713-03 |
Phosphorus (P) and phosphorus pentoxide (P2O5) |
| Phosphate HighRange |
0.0 to 30.0 mg/L (as PO43-) |
0.1 mg/L |
Reading ±4% ±1.0 mg/L @25 ℃ |
HI93717-01 HI93717-03 |
Phosphorus (P) and phosphorus pentoxide (P2O5) |
| Potassium |
0.0 to 20.0 mg/L (as K) |
0.1 mg/L |
Reading ±7% ±3.0 mg/L @25 ℃ |
HI93750-01 HI93750-03 |
Potassium chloride (K2O) |
| Silica Low Range |
0.00 to 2.00 mg/L (as SiO2) |
0.01 mg/L |
Reading ±3% ±0.03 mg/L @25 ℃ |
HI93705-01 HI93705-03 |
Silicon (Si) |
| Silica High Range |
0 to 200mg/L (as SIO2) |
1 mg/L |
Reading ±5% ±1mg/L @25 ℃ |
HI93770-01 HI93770-03 |
Silicon (Si) |
| Silver |
0.000 to 1.000 mg/L(as Ag) |
0.001mg/L |
Reading ±5% ±0.020 mg/L@25 ℃ |
HI93737-01 HI93737-03 |
--- |
| Sulfate |
0 to 150 mg/L (as SO42-) |
1 mg/L |
Reading ±3% ±5mg/L @25 ℃ |
HI93751-01 HI93751-03 |
--- |
| Anionic Surfactants |
0.00 to 3,50mg/L (as SDBS) |
0.01mg/L |
Reading ±3% ±0.04mg/L @25 ℃ |
HI95769-01 | --- |
| Zinc |
0.00 to 3,00mg/L (as Zn) |
0.01mg/L |
Reading ±3% ±0.03mg/L @25 ℃ |
HI93731-01 HI93731-03 |
--- |
Meter, HI83300-11 NIST standard measurement curve calibration kit (optional), Chinese and English instruction manual
Case Studies
Municipal Wastewater Treatment · Hanna — Stock Configuration Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.
Configuration
Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.
Food & Beverage · Hanna — Stock Configuration Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.
What We Did
We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Hanna — Stock Configuration Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.
Delivery Approach
Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.
Power & Energy · Hanna — Stock Configuration Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.
Implementation
The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.
Related Products
HANNA InstrumentsPortable multi-range conductivity meter
HANNA InstrumentsLow range ammonia nitrogen portable photometer
HANNA InstrumentsPortable multi-range turbidimeter
HANNA InstrumentsSaltwater aquarium salinity meter
HANNA InstrumentsPortable honey color analyzer
HANNA InstrumentsPortable free chlorine photometer
HANNA InstrumentsPortable free and total chlorine photometer
HANNA Instruments