Overview
The HI-83746 photometer is for the determination of reducing sugars in wine. Hanna's photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.
Built-in timer Display of time remaining before a measurement is taken. Ensures that all readings are taken at the appropriate reaction intervals for the test being performed. Zero key A simple press of the zero key on the face of the meter will account for the colour and imperfections in the oil sample before reagent addition.
GLP Review of the last calibration date. Auto shut-off Automatic shut-off after 15 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally left on.
Battery status indicator Indicates the amount of battery life left. Error messages Messages on display alerting to problems including no cap, high zero, and standard too low. Units of measure Appropriate unit of measure is displayed along with reading.
Typical content of reducing sugars in must and wine Must sweet must 20-25 % 200-250 g/L normal 10-20 % 100-200 g/L in fermentation 4-12.5 % 40-125 g/L Wine sweet 2.5-12.5 % 25-125 g/L semi sweet 0.8-2.5 % 8-25 g/L almost dry 0.2-0.8 % 2-8 g/L dry 0-0.2 % 0-2 g/L Significance of Use Sugar is an essential component in the production of wine. During alcoholic fermentation, yeast consume sugars found in the grape juice, or must, and converts it to ethyl alcohol and carbon dioxide. In the case of certain styles of wine such as semi-sweet or dessert wines, some sugar is allowed to remain post-fermentation.
This residual sugar can serve to provide a sweeter character to the final blend or play a role in microbial stability. The primary fermentable sugars found in grapes are glucose and fructose. These two simple sugars are also known as reducing sugars because they contain functional groups capable of being oxidised under certain conditions.
After reaction with excess alkaline cupric tartrate (Fehling reagents), the content of reducing sugars can be determined colorimetrically. The Fehling method is not an exact determination but an index of the reducing sugar concentration, because the reaction depends upon the amount and type of reducing sugars present. When the reducing sugar content is known at the beginning of fermentation, the potential alcohol degree can be estimated by multiplying the sugar concentration (in g/L) by 0.06.
Specifications
| Parameter | Value |
|---|---|
| SKU | HI83746-02 |
| Range | 0.00 to 50.00 g/L (ppt) |
| Resolution | 0.25 g/L |
| Accuracy | ±0.50 g/L ±5% of reading |
| Light Source | Tungsten lamp |
| Sensor | Silicon photocell with narrow band interference filter @ 610 nm |
| Method | Fehling |
| Environment | 0 to 50°C; max 95% RH non-condensing |
| Battery Type | (4) 1.5V AA batteries/12 VDC adapter |
| Auto Shut-off | After 15 minutes of non-use |
| Dimensions | 224 x 87 x 77 mm |
| Weight | 512 g |
| Ordering Information | HI-83746-02 (230V) is supplied with glass cuvettes and caps (4), reagents for about 20 tests (HI-83746-20), HI-93703-59 Charcoal, 200μL, automatic pipette with two plastic tips, 1000 μL automatic pipette with plastic tips (2), instruction sheet for automatic pipette, spoon, funnel, filter paper (25), cuvette wiping cloth, 12 VDC adapter, batteries, instructions and Instrument quality certificate, rigid carrying case. |
| Optional Reagents | HI-83746-20 reducing sugar reagent set (20 tests); HI-93703-59 charcoal for decoloration of red wine (about 100 tests), HI-839800 COD test tube heater (required) |
Accessories
- HI-839800-02: HI-839800 25 Vial Thermo-Reactor
- HI-93703-59: HI-93703-59 Charcoal, Activated (10g)
Related Products
HANNA InstrumentsFoodcare pH 7.01 Buffer Solution - 500ml FDA Bottle
HANNA InstrumentsFoodcare pH 10.01 Buffer Solution - 500ml FDA Bottle
HANNA InstrumentspH Tester for Meat with built-in Specialised Electrode, Compatible with FC097 Meat Blade
HANNA InstrumentsRefractometer for Inverted sugar 0 to 85% scale
HANNA Instruments6.86 pH Foodcare Buffer Calibration Solution, 500 mL FDA bottle
HANNA InstrumentsElectrode Cleaning Solution for Oil and Fats, FDA 500 mL bottle
HANNA InstrumentsElectrode Cleaning Solution for Wine Deposits (Winemaking), 25 x 20 mL sachets
HANNA Instruments