Overview
pH Analog Controller with Self-diagnostic test The HI 8710 is a panel mounted pH Controller with self diagnostic and test. The user can set: the setpoint for acid or alkaline dosage, the tolerance of the setpoint before an alarm is activated, the dosage mode: automatic, continuous in or OFF and the over dosage control by setting the overtime dosage knob. Key features Backlit LCD Operational mode LED indicators Transparent splash-proof cover Fail Safe Function - the alarm relay is activated at power down Main benefits Extended temperature compensation range -20 to 100 °C Supports potential matching pin connection Auto-diagnostic tests for pH electrode and instrument status Supplied with Mounting brackets Instructions Range -2.00 to 16.00 pH Resolution 0.01 pH Accuracy ±0.02 pH (0 to 100°C) ±0.05 pH (-20 to 0°C) ±0.5% (input transmitter) Input High impedance 10 12 Ohm; Reference and Matching pin inputs are available; 4-20 mA Power Output ±5 Vcc; 150 mA max load for amplified electrodes Calibration Offset: ±2 pH with OFFSET trimmer; Slope: 80 to 110% with SLOPE trimmer Temperature Compensation fixed or automatic with Pt100, from -20 to 100°C (-4 to 212°F) Recorder Output 0-20 mA or 4-20 mA (isolated) Setpoint Relay 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected) Setpoint Range -2.00 to 16.00 pH Alarm Relay 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected) Alarm Range 0.2 to 3.00 pH Consent Relay 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected) Dosing Control OFF/AUTO/ON with selection switch Over Dosing Control Adjustable, from 5 min to 60 min with knob or Disable by wire strap - on rear panel Backlight Continuous ON Power Supply 115 or 230 Vac; 50/60 Hz Enclosure Black anodized aluminum body; front and back with ABS; transparent splash-proof front cover Environment -10 to 50°C (14 to 122°F); RH max 95% non-condensing Panel Cutout 141 x 69 mm (5.6 x 2.7") Weight 1 kg (2.2 lb.)
Specifications
| Parameter | Value |
|---|---|
| SKU | HI8710 |
| Range - pH | -2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.02 pH (0 to 100°C) ±0.05 pH (-20 to 0°C) ±0.5% (input transmitter) |
| Input | High impedance 10 12 Ohm; Reference and Matching pin inputs are available; 4-20 mA |
| Power Output | ±5 Vcc; 150 mA max load for amplified electrodes |
| Calibration | Offset: ±2 pH with OFFSET trimmer; Slope: 80 to 110% with SLOPE trimmer |
| Temperature Compensation | fixed or automatic with Pt100, from -20 to 100°C (-4 to 212°F) |
| Recorder Output | 0-20 mA or 4-20 mA (isolated) |
| Setpoint Relay | 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected) |
| Setpoint Range | -2.00 to 16.00 pH |
| Alarm Relay | 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected) |
| Alarm Range | 0.2 to 3.00 pH |
| Consent Relay | 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected) |
| Dosing Control | OFF/AUTO/ON with selection switch |
| Over Dosing Control | Adjustable, from 5 min to 60 min with knob or Disable by wire strap - on rear panel |
| Backlight | Continuous ON |
| Power Supply | 115 or 230 Vac; 50/60 Hz |
| Enclosure | Black anodized aluminum body; front and back with ABS; transparent splash-proof front cover |
| Environment | -10 to 50°C (14 to 122°F); RH max 95% non-condensing |
| Panel Cutout | 141 x 69 mm (5.6 x 2.7") |
| Weight | 1 kg (2.2 lb.) |
Manuals and documentation
Related Products
HANNA InstrumentsEPA Compliant Turbidity and Free & Total Chlorine Meter
HANNA InstrumentsHardness, High Range Test Kit
HANNA InstrumentsAlkaline battery size AAA
Large pump head assembly
HANNA InstrumentsRugged Case for Waterproof Meters with Moulded Insert
HANNA InstrumentsAuger for Ground Penetration
HANNA InstrumentsChromium VI High Range Handheld Colorimeter - Checker HC
HANNA Instruments