pH Analog Controller with Self-diagnostic test The HI 8710 is a panel mounted pH Controller with self diagnostic and test. The user can set: the setpoint for acid or alkaline dosage, the tolerance of the setpoint before an alarm is activated, the dosage mode: automatic, continuous in or OFF and the over dosage control by setting the overtime dosage knob. Key features Backlit LCD Operational mode LED indicators Transparent splash-proof cover Fail Safe Function - the alarm relay is activated at power down Main benefits Extended temperature compensation range -20 to 100 °C Supports potential matching pin connection Auto-diagnostic tests for pH electrode and instrument status Supplied with Mounting brackets Instructions Range -2.00 to 16.00 pH Resolution 0.01 pH Accuracy ±0.02 pH (0 to 100°C) ±0.05 pH (-20 to 0°C) ±0.5% (input transmitter) Input High impedance 10 12 Ohm; Reference and Matching pin inputs are available; 4-20 mA Power Output ±5 Vcc; 150 mA max load for amplified electrodes Calibration Offset: ±2 pH with OFFSET trimmer; Slope: 80 to 110% with SLOPE trimmer Temperature Compensation fixed or automatic with Pt100, from -20 to 100°C (-4 to 212°F) Recorder Output 0-20 mA or 4-20 mA (isolated) Setpoint Relay 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected) Setpoint Range -2.00 to 16.00 pH Alarm Relay 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected) Alarm Range 0.2 to 3.00 pH Consent Relay 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected) Dosing Control OFF/AUTO/ON with selection switch Over Dosing Control Adjustable, from 5 min to 60 min with knob or Disable by wire strap - on rear panel Backlight Continuous ON Power Supply 115 or 230 Vac; 50/60 Hz Enclosure Black anodized aluminum body; front and back with ABS; transparent splash-proof front cover Environment -10 to 50°C (14 to 122°F); RH max 95% non-condensing Panel Cutout 141 x 69 mm (5.6 x 2.7") Weight 1 kg (2.2 lb.)

Specifications

ParameterValue
SKUHI8710
Range - pH-2.00 to 16.00 pH
Resolution0.01 pH
Accuracy±0.02 pH (0 to 100°C) ±0.05 pH (-20 to 0°C) ±0.5% (input transmitter)
InputHigh impedance 10 12 Ohm; Reference and Matching pin inputs are available; 4-20 mA
Power Output±5 Vcc; 150 mA max load for amplified electrodes
CalibrationOffset: ±2 pH with OFFSET trimmer; Slope: 80 to 110% with SLOPE trimmer
Temperature Compensationfixed or automatic with Pt100, from -20 to 100°C (-4 to 212°F)
Recorder Output0-20 mA or 4-20 mA (isolated)
Setpoint Relay1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected)
Setpoint Range-2.00 to 16.00 pH
Alarm Relay1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected)
Alarm Range0.2 to 3.00 pH
Consent Relay1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected)
Dosing ControlOFF/AUTO/ON with selection switch
Over Dosing ControlAdjustable, from 5 min to 60 min with knob or Disable by wire strap - on rear panel
BacklightContinuous ON
Power Supply115 or 230 Vac; 50/60 Hz
EnclosureBlack anodized aluminum body; front and back with ABS; transparent splash-proof front cover
Environment-10 to 50°C (14 to 122°F); RH max 95% non-condensing
Panel Cutout141 x 69 mm (5.6 x 2.7")
Weight1 kg (2.2 lb.)