Overview
HI-8711 allows the selection of two set points with two independent outputs for acid and alkaline dosages. Each model accepts either a direct input from a pH or ORP electrode or from a transmitter through 4-20 mA input. The instrument also provides ±5V power output and input terminals for amplified electrodes.
In addition, you can choose the output configuration for connecting a recorder or a PLC, between 0-20 or 4-20 mA. The HI-8711 incorporates adjustable overtime dosage protection from 5 to 60 minutes. If dosing exceeds selected time, the alarm will be triggered and the dosing contact will deactivate.
This feature can be activated or deactivated. A removable, transparent splash-proof cover protects the front panel.
Specifications
| Parameter | Value |
|---|---|
| SKU | HI8711 |
| Range - pH | 0.00 to 14.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.02 pH (0 to 100°C) ±0.05 pH (-20 to 0°C) ±0.5% (input from transmitter) |
| Input | High impedance 10 12 Ohm; Reference and Matching pin inputs are available; 4-20 mA |
| Power Output | ±5 Vcc; 150 mA max load for amplified electrodes |
| Calibration | Offset: ±2 pH with OFFSET trimmer; Slope: 80 to 110% with SLOPE trimmer |
| Temperature Compensation | fixed or automatic with Pt100, from -20 to 100°C (-4 to 212°F) |
| Recorder Output | 0-20 mA or 4-20 mA (isolated) |
| Setpoint Relay | 2, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected) |
| Setpoint Range | 0.00 to 14.00 pH |
| Alarm Relay | 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected) |
| Alarm Range | 0.2 to 3.00 pH |
| Dosing Control | OFF/AUTO/ON with selection switch |
| Over Dosing Control | Adjustable, from 5 min to 60 min with button or disable by wire strap - on rear panel |
| Backlight | Continuous ON |
| Power Supply | 115 or 230 Vac; 50/60 Hz |
| Enclosure | Flame retardant ABS body and front panel; transparent splash-proof front cover |
| Environment | -10 to 50°C (14 to 122°F); RH max 95% non-condensing |
| Panel Cutout | 141 x 69 mm (5.6 x 2.7") |
| Weight | 1 kg (2.2 lb.) |
Manuals and documentation
Related Products
HANNA InstrumentsEPA Compliant Turbidity and Free & Total Chlorine Meter
HANNA InstrumentsHardness, High Range Test Kit
HANNA InstrumentsAlkaline battery size AAA
HANNA InstrumentsSyringe 10mL with Luer Lock
Large pump head assembly
HANNA InstrumentsRugged Case for Waterproof Meters with Moulded Insert
HANNA InstrumentsAuger for Ground Penetration
HANNA Instruments