Overview
These controllers allow the direct connection of a potentiometric conductivity probe (HI 7638) with a cable up to 20 meters long, without using any transmitter. Automatic temperature compensation ensures fast, accurately compensated readings even during sudden temperature fluctuations Four different models are available with different measurement ranges Displays values on the easy to read LCD with backlighting Direct connection of a potentiometric conductivity probe (HI-7638) with a cable up to 20 meters long, without using a transmitter Four different models are available with different measurement ranges, to satisfy any application requirements. The output configuration for connecting a recorder or a PLC can be chosen between 0-20 or 4-20 mA.
The LED on the front panel indicates the operating status of the controller. The automatic temperature compensation (ATC) is performed directly by the HI-7638 probe with built-in temperature sensor. The front panel is protected behind a transparent splash-proof cover.
Order Information: The HI-943500 series is supplied with mounting brackets and instructions. HI-943500A: 0.0 to 199.9 mS/cm HI-943500B: 0.00 to 19.99 mS/cm HI-943500C: 0 to 1999 µS/cm HI-943500D: 0.0 to 199.9 µS/cm Range 0.0 to 199.9 mS/cm Resolution 0.1 mS/cm Accuracy ±2% F.S. Temperature Compensation automatic, 0 to 60°C (32 to 140°F), with ß=2%/°C Recorder Output 4-20 mA (isolated) Setpoint Relay 1, isolated, 2A, Max.
240 V, resistive load, 1,000,000 strokes Alarm Relay 1, isolated, 2A, Max. 240 V, resistive load, 1,000,000 strokes Power Supply 115/230 ±10% Vac; 50/60 Hz Enclosure black anodised aluminium body; front and back with ABS; transparent splash-proof front cover Environment -10 to 50°C (4 to 122°F); RH max 95% non condensing Panel Cutout 141 x 69 mm (5.6 x 2.7") Weight 1 kg (2.2 lb.)
Specifications
| Parameter | Value |
|---|---|
| SKU | HI943500A |
| Range | 0.0 to 199.9 mS/cm |
| Resolution | 0.1 mS/cm |
| Accuracy | ±2% F.S. |
| Temperature Compensation | automatic, 0 to 60°C (32 to 140°F), with ß=2%/°C |
| Recorder Output | 4-20 mA (isolated) |
| Setpoint Relay | 1, isolated, 2A, Max. 240 V, resistive load, 1,000,000 strokes |
| Alarm Relay | 1, isolated, 2A, Max. 240 V, resistive load, 1,000,000 strokes |
| Power Supply | 115/230 ±10% Vac; 50/60 Hz |
| Enclosure | black anodised aluminium body; front and back with ABS; transparent splash-proof front cover |
| Environment | -10 to 50°C (4 to 122°F); RH max 95% non condensing |
| Panel Cutout | 141 x 69 mm (5.6 x 2.7") |
| Weight | 1 kg (2.2 lb.) |
Related Products
HANNA InstrumentsEPA Compliant Turbidity and Free & Total Chlorine Meter
HANNA InstrumentsHardness, High Range Test Kit
HANNA InstrumentsAlkaline battery size AAA
Large pump head assembly
HANNA InstrumentsRugged Case for Waterproof Meters with Moulded Insert
HANNA InstrumentsAuger for Ground Penetration
HANNA InstrumentsChromium VI High Range Handheld Colorimeter - Checker HC
HANNA Instruments