Product Overview
-
HI96748 portable photometer is for low range measurement of manganese. Hanna's portable photometers use an advanced optical system; the combination of a special tungsten lamp, narrow band interference filter, and silicon photodetector ensures accurate photometric readings every time. Hanna's exclusive CAL Check™ feature uses ready-made NIST traceable standards to verify meter verification and calibration. The dedicated cuvette locking system ensures that the cuvette is inserted into the measuring cell in the same position every time to maintain a consistent path length.
-
Features at a glance
-
CAL Check™ - allows performance verification and calibration of the meter using CAL Check NIST traceable secondary standards.
-
GLP - records the date the last user calibration was performed.
-
Built-in timer - allows the use of a timer to ensure the chemical reaction uses the appropriate 3 minute 30 second reaction time. When the timer countdown ends, the meter will automatically read the reading. This feature ensures consistency between multiple users.
-
Indexing detent on the meter - the meter has a detent that allows the lock and key to engage with the cuvette cap. This ensures that the cuvette is consistently indexed (same position) so that the same path length is maintained for accurate results.
-
Cooling lamp indicator - in order to maintain narrow band light, it is necessary to keep the temperature of the optical components consistent. This photometer has a cooling lamp indicator that is displayed for a short period before each measurement so that the components cool and the highest possible accuracy is obtained.
-
Error messages - displayed messages warn of problems, including no cap, over-range and under-range readings, and light source errors.
-
Auto shut-off - when the meter is in measurement mode, it automatically shuts off after 10 minutes of non-use. Prevents wasting battery if the meter is accidentally left on.
-
Battery status indicator
-
The instrument has a battery level indicator to show reaming life as follows:
-
3 lines, 100% capacity
-
2 lines, 66% capacity
-
1 line, 33% capacity
-
When the battery is below 10%, the battery icon flashes.
-
Measurement units - the appropriate measurement unit is displayed together with the reading.

-
Manganese is one of the most common metals in nature and is used in many industrial applications, such as fertilizer production and the pharmaceutical industry. Manganese salts are also used in ferrous alloys (steel manufacturing) and non-ferrous alloys because they can improve their corrosion resistance and hardness.
-
HI96748 uses the 1-(2-pyridylazo)-2-naphthol PAN method to measure manganese concentrations of less than 300μg/L (ppb) manganese. When the reagent is added to a sample containing manganese, the sample will turn orange; the greater the concentration, the deeper the color. The associated color change is then analyzed colorimetrically according to the Beer-Lambert law. This principle states that light is absorbed by the complementary color, and the emitted radiation depends on the concentration. For the determination of manganese, a 525nm (green) narrow band interference filter allows only the silicon photodetector to detect green light while ignoring all other visible light emitted from the tungsten lamp. As the color change of the reacted sample increases, the absorbance of light at a specific wavelength also increases, while the transmittance decreases.

-
HI96748 is available as a kit (HI96748C), including:
-
Portable photometer
-
Sample cuvettes (2)
-
Caps
-
CAL Check™ standards with certificate
-
Cuvette cleaning cloth
-
Scissors
-
Sturdy carrying case
-
The carrying case has thermoformed inserts for the meter and accessories
-
*Reagents ordered separately
-
CAL Check™ standards with certificate
-
HI96748-11 CAL Check™ standards are used for calibration and performance verification of photometers with the CAL Check™ feature.
-
Certificate of analysis provided
-
Lot number
-
Expiration date
-
Standard value at 25°C
-
NIST traceable reference meter
-
Storage container provided
-
Lightproof
-
Protects against accidental breakage

| SKU | HI96748 |
|---|---|
| Product Name | Manganese Low Range Portable Photometer - HI96748 |
| Quote Required | Yes |
| Manganese Range | 0 to 300 μg/L (ppb) |
| Manganese Resolution | 1 µg/L |
| Manganese Accuracy | ±10 μg/L ±3% of reading |
| Manganese Method | adaptation of the 1-(2-pyridylazo)-2-naphtol PAN method |
| Photometer/Colorimeter Light Source | tungsten lamp |
| Photometer/Colorimeter Light Detector | silicon photocell with narrow band interference filter @ 525 nm |
| Battery Type/Life | 9V battery |
| Automatic Shut-Off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
| Weight | 360g (12.7oz.) |
| Dimensions | 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”) |
| Ordering Information | HI96748 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual. CAL Check™ standards and testing reagents sold separately. |
Case Studies
Municipal Wastewater Treatment · Hanna — Stock Configuration Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.
Configuration
Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.
Food & Beverage · Hanna — Stock Configuration Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.
What We Did
We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Hanna — Stock Configuration Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.
Delivery Approach
Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.
Power & Energy · Hanna — Stock Configuration Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.
Implementation
The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.
Related Products
HANNA InstrumentsPortable multi-range conductivity meter
HANNA InstrumentsLow range ammonia nitrogen portable photometer
HANNA InstrumentsPortable multi-range turbidimeter
HANNA InstrumentsSaltwater aquarium salinity meter
HANNA InstrumentsPortable honey color analyzer
HANNA InstrumentsPortable free chlorine photometer
HANNA InstrumentsPortable free and total chlorine photometer
HANNA Instruments