Free chlorine ultra low range portable photometer

Product Overview

  • HI96762 is no longer available.

  • Below is a link to a new meter that has been upgraded with many advanced features, including an improved optical system, dot matrix LCD, which provides a graphical tutorial mode to help users complete the measurement process, and is waterproof, including the cuvette assembly.

  • Both meters use the same reagents.

  • The HI96762 portable photometer is used for ultra-low range measurement of free chlorine in various water samples. Hanna's portable photometers use an advanced optical system; the combination of a special tungsten lamp, narrow band interference filter, and silicon photodetector ensures accurate photometric readings every time. Hanna's exclusive CAL Check™ feature uses ready-made NIST traceable standards to verify meter validation and calibration. The dedicated cuvette locking system ensures that the cuvette is inserted into the measuring cell in the same position every time to maintain a consistent path length.

  • Features at a glance

  • CAL Check™ - allows performance verification and calibration of the meter using CAL Check NIST traceable secondary standards.

  • GLP - records the date the last user calibration was performed.

  • Built-in timer - allows the use of a timer to ensure the chemical reaction uses the appropriate 3 minute 30 second reaction time. When the timer countdown ends, the meter will automatically read the reading. This feature ensures consistency between multiple users.

  • Indexing indentation on the meter - the meter has an indentation that allows a lock and key to fit with the cuvette cap. This ensures that the cuvette is consistently indexed (same position) in order to maintain the same path length for accurate results.

  • Cooling lamp indicator - in order to maintain narrow band light, it is necessary to keep the temperature of the optical components consistent. This photometer has a cooling lamp indicator that displays for a short period before each measurement in order to allow the components to cool and obtain the highest possible accuracy.

  • Error messages - displayed messages warn of problems, including no cap, over-range and under-range readings, and light source errors.

  • Auto shut-off - when the meter is in measurement mode, it automatically shuts off after 10 minutes of non-use. Prevents battery waste if the meter is accidentally left on.

  • Battery status indicator

  • The instrument has a battery level indicator to show reaming life as follows:

  • 3 lines, 100% capacity

  • 2 lines, 66% capacity

  • 1 line, 33% capacity

  • When the battery is below 10%, the battery icon will flash.

  • Measurement units - the appropriate measurement units are displayed with the reading.

  • Free chlorine is one of the oldest and most common forms of disinfection, and chlorine improves water quality by destroying pathogenic microorganisms and reacting with other organic and inorganic substances. Chlorine levels must be actively monitored to ensure there is sufficient chlorine for disinfection and to control adverse effects such as taste, odor, and the potential to form harmful disinfection by-products with organic matter.

  • The HI96762 uses an adaptation of standard method 4500 Cl G to measure free chlorine concentrations less than 0.500 mg/L (ppm). When DPD reagent is added to a sample containing free chlorine, the sample will turn pink; the greater the concentration, the deeper the color. The associated color change is then analyzed colorimetrically according to the Beer-Lambert law. This principle states that light is absorbed by the complementary color, and the emitted radiation depends on the concentration. For free chlorine determination, a 525 nm (green) narrow band interference filter allows only the silicon photodetector to detect green light while ignoring all other visible light emitted from the tungsten lamp. As the color change of the reacted sample increases, the absorbance of light at a specific wavelength also increases, while transmittance decreases.

  • The HI96762 is available as a kit (HI96762C), including:

  • Portable photometer

  • Sample cuvettes (2)

  • Caps

  • CAL Check™ standards with certificate

  • Cuvette cleaning cloth

  • Scissors

  • Rugged carrying case

  • The carrying case has thermoformed inserts for the meter and accessories

  • *Reagents ordered separately

  • CAL Check™ standards with certificate

  • HI96762-11 CAL Check™ standards are used for calibration and performance verification of photometers with the CAL Check feature.

  • Certificate of analysis provided

  • Lot number

  • Expiration date

  • Standard value at 25°C

  • NIST traceable reference meter

  • Storage container provided

  • Lightproof

  • Protects against accidental breakage

SKU HI96762-web
Product Name Free Chlorine Ultra Low Range Portable Photometer - HI96762
Quote Required Yes
Free Chlorine Range da 0.000 a 0.500 mg/L
Free Chlorine Resolution 0.001 mg/L (ppm)
Free Chlorine Accuracy ±0.020 mg/L ±3% della lettura
Chlorine Method adattamento del metodo standard 4500-Cl G
Battery Type/Life batteria da 9V
Automatic Shut-Off dopo 10 minuti di inutilizzo in modalità di misura; dopo 1 ora di inutilizzo in modalità di calibrazione
Environment da 0 a 50°C (da 32 a 122°F); U.R. max 95% senza condensa
Weight 360g (12.7oz.)
Dimensions 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”)
Ordering Information HI96762 è fornito con cuvette di misura (2) con tappi, batteria da 9V, certificato di qualità e manuale di istruzioni.
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.