Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI96812

HI96812

Portable Baumé refractometer

Juice and wine sugar refractometer

HI96812 uses degrees Baumé as the measurement unit. Degrees Baumé is a method of expressing solution concentration, originally designed to measure sodium chloride content in water. In the winemaking industry, degrees Baumé can be used to measure the sugar content in grape juice. Based on the official methods of analysis of AOAC International, HI96812 can convert % Brix readings to degrees Baumé. One degree Baumé is approximately equal to 1.8% Brix, and when wine is fully fermented, one degree Baumé can also be roughly calculated as 1% alcohol by volume.

Dual-line LCD display

Temperature reading is displayed below the measurement value

ATC

Automatic temperature compensation·

BEPS

Low battery alert ensures accurate and valid readings

Waterproof

Suitable for laboratory and field measurements

Fast and accurate measurement

Displays measurement results in 1.5 seconds

One-point calibration

Calibrate with distilled or deionized water 

Micro-volume samples

Requires only 2 drops of sample

Auto power off

Automatically powers off after three minutes of non-use

Stainless steel sample chamber

Easy to clean and corrosion-resistant

Simple operation

Simply add sample and press to read, quick and easy 

ABS heat-shrink plastic carrying case

Sugar content

Measuring range 0 to 28° Baumé
Resolution 0.1% Baumé
Accuracy (@25℃/77℉) ±0.1° Baumé

Temperature

Measuring range 0 to 80℃ (32 to 176 ℉)
Resolution ±0.1 ℃(0.1℉)
Accuracy (@25℃/77℉) ±0.3 ℃(0.5℉)

Other parameters

Temperature compensation Automatic temperature compensation 10-40℃(50 to 104 ℉)
Measurement response time Approx. 1.5 seconds
Minimum sample volume 100 μL (completely covers the prism)
Light source Yellow LED
Sample cell Stainless steel cell body, flint prism
Auto power off After three minutes of non-use
Enclosure protection class IP65
Power supply type/battery life 9V/approx. 5000 readings
Dimensions/weight 192x102x67 mm (7.6x4.01x2.6”)/420g(14.8oz.)
Basic configuration Meter, battery, instruction manual

Meter, battery, instruction manual

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.