HI96821 refractometer measures the refractive index of liquid solution samples and converts it to the sodium chloride content of the sample. Designed for the food industry, not suitable for seawater salinity measurement.
-
Refractive index measurement is very simple and fast. The user only needs to calibrate the refractometer with distilled or deionized water, then place two drops of the sample onto the sample chamber, and within a few seconds the sodium chloride measurement value of the sample is obtained. The instrument automatically performs temperature compensation, ensuring accurate and reliable measurement results.
-
The instrument uses internationally recognized reference unit conversion and temperature compensation methods, and can display NaCl concentration in 4 different reference units: g/100g, g/100 mL, specific gravity, and °Baumé.
-
The second line of the LCD screen can simultaneously display the measurement temperature, low battery indicator icon, and other help information.
Dual-line LCD display
Temperature reading displayed below the measurement value
ATC
Automatic temperature compensation·
BEPS
Low battery alert, ensuring accurate and valid readings
IP65 waterproof
Suitable for laboratory and field measurement
Fast and accurate measurement
Displays measurement results in 1.5 seconds
One-point calibration
Calibrate with distilled or deionized water
Micro-volume sample
Only 2 drops of sample required
Auto power off
Automatically shuts off after three minutes of non-use
Stainless steel sample chamber
Easy to clean and corrosion-resistant
Easy to operate
Simply add sample and press to read, simple and fast
ABS heat-shrink plastic carrying case
|
g/100g |
Measuring range | 0 to 28 |
| Resolution | 0.1 | |
| Accuracy (@25 C/77° F) | ±0.2 | |
|
g/100mL |
Measuring range | 0 to 34 |
| Resolution | 0.1 | |
| Accuracy (@25 C/77° F) | ±0.2 | |
|
Specific Gravity (S.G.) |
Measuring range | 1.000 to 1.216 |
| Resolution | 0.001 | |
| Accuracy (@25 C/77° F) | ±0.002 | |
|
°Baumé |
Measuring range | 0 to 26 |
| Resolution | 0.1 | |
| Accuracy (@25 C/77° F) | ±0.2 | |
|
Temperature |
Measuring range | 0 to 80 ℃(32 to 176 ℉) |
| Resolution | 0.1℃(0.1 ℉) | |
| Accuracy (@25 C/77° F) | ±0.3℃(±0.5 ℉) | |
|
Other specifications |
Temperature compensation | 10 ℃ to 40 ℃ automatic temperature compensation |
| Measurement time | Approx. 1.5 seconds | |
| Minimum sample volume | 100 μL (fully covering the prism) | |
| Light source | Yellow LED | |
| Sample chamber | Stainless steel sample chamber, hard glass prism | |
| Auto power off | After 3 minutes of non-use | |
| Enclosure protection class | IP65 | |
| Power supply/battery life | 9V/approx. 5000 readings | |
| Dimensions/weight | 192x102x67 mm(7.6x4.01x2.6“) | |
| Basic configuration | Meter, battery, and instruction manual | |
Meter, battery, and instruction manual
Case Studies
Municipal Wastewater Treatment · Hanna — Stock Configuration Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.
Configuration
Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.
Food & Beverage · Hanna — Stock Configuration Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.
What We Did
We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Hanna — Stock Configuration Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.
Delivery Approach
Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.
Power & Energy · Hanna — Stock Configuration Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.
Implementation
The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.
Related Products
HANNA InstrumentsPortable multi-range conductivity meter
HANNA InstrumentsLow range ammonia nitrogen portable photometer
HANNA InstrumentsPortable multi-range turbidimeter
HANNA InstrumentsSaltwater aquarium salinity meter
HANNA InstrumentsPortable honey color analyzer
HANNA InstrumentsPortable free chlorine photometer
HANNA InstrumentsPortable free and total chlorine photometer
HANNA Instruments