Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI97105C

HI97105C
Marine Master Photometer Kit
Measures: Marine pH, Alkalinity, Ammonia, Calcium, Magnesium, Nitrate LR, Nitrate HR, Nitrite ULR, Phosphate ULR. Each HI-97105C is supplied with: Sample cuvette (2 pcs.) Sample cuvette cap (2 pcs.) M

Overview

Measures: Marine pH, Alkalinity, Ammonia, Calcium, Magnesium, Nitrate LR, Nitrate HR, Nitrite ULR, Phosphate ULR. Each HI-97105C is supplied with: Sample cuvette (2 pcs.) Sample cuvette cap (2 pcs.) Marine pH reagent, 30 mL dropper Marine Alkalinity reagent, 30 mL Marine Calcium reagents starter kit Marine Nitrate reagents High Range starter kit Marine Nitrite reagents ULR starter kit Marine Phosphate reagents Ultra Low Range starter kit 1 mL graduated syringe with tip (2 pcs.) Mini pipette with tip (1 pc.) 3 mL Pasteur pipette (2 pcs.) 1.5V AA Alkaline batteries (3 pcs.) Cloth for wiping cuvettes Scissors Instrument quality certificate Instruction manual (Please note: not all reagents and the Cal Check standard are included in this kit, so check your testing requirements are covered when ordering. See specification table to choose further reagents.

Additional costs apply.) About the photometer The HI-97105 is designed to accurately determine pH, Alkalinity, Calcium, Nitrate, Nitrite, and Phosphate levels in aquariums and marine biology applications. The HI-97105 Marine Master Photometer combines accuracy and ease of use in a simple, portable design. The advanced optical system provides lab-quality accuracy, while its user-friendly design is easy for any aquarium user, making it the perfect photometer for your water quality testing needs.

No warm up time needed before taking a measurement. Tutorial mode for easy step-by-step instructions CAL Check TM for performance verification and calibration Better Features for Better Testing Let your photometer guide you through setup, calibration, and testing with on-screen tutorials and animations, so you always know the next step. Simply access Tutorial Mode at any stage in the setup or measurement process with the dedicated help key.

The auto-off feature prolongs battery life for peace-of-mind and energy savings if the meter is accidentally left on. When the battery level is below 10%, a warning symbol will blink to indicate low battery condition. When low battery power may affect your results, the meter will shut down to avoid erroneous readings caused by low battery level.

Data Logging Missed a measurement? No need to worry because your photometer will automatically log the last 50 measurements. The results can be viewed instantly using the Log Recall Menu.

CAL Check TM Validation Hanna’s exclusive CAL Check TM feature provides a stress-free, straightforward way to ensure your photometer is working properly. Simply insert the certified CAL Check TM standards and let your meter guide you through validation. If your photometer is out of specification for any reason, simply calibrate to your standard.

Please download the Safety Datasheet(s) which provide more detail on the reagents before use; click on the link in the “safety data sheets” paragraph below. Advanced Optical System A Light Emitting Diode (LED) provides more light while using less power, and a narrow band interference filter results in more accurate and repeatable readings. Built Better Designed to withstand the knocks, drops, and spills of real life, the new IP67 body ensures top performance in any environment.

Internal optics are sealed from outside dust, dirt, and water. In addition, it floats, just in case you drop your meter in water. This photometer uses an exclusive positive locking system to ensure that the cuvettes are placed into the holder in the same position for accurate readings every time.

Portable Design Made to fit comfortably in your hand for on-the-go testing or sit on a table for benchtop use, a backlit LCD display provides at-a-glance readings from any angle - day or night. The supplied AA batteries provide life for more than 800 measurements. We believe that buying a meter should be simple.

Your HI-97105 photometer has many of the necessary accessories needed for successful measurements. Safety Data Sheets Access safety data sheets online here. When using any form of chemical, it is important you download the relevant safety datasheet and make yourself aware of any precautions you should take when handling the chemical.

You can access our library of safety datasheets and download a copy by following the link below. Please note that the '-' in HI- products should be removed from all searches to find the correct information. click here

Specifications

ParameterValue
SKUHI97105C
Alkalinity, Marine Range0.0 to 20.0 dkH 0 to 357 ppm (as CaCo 3 )
Alkalinity, Marine Resolution0.1 dkH
Alkalinity, Marine Accuracy±0.3 dKH ±5 % of reading at 25 °C ±5 ppm ±5 % of reading at 25 °C
Alkalinity, Marine MethodColorimetric Method - The reaction causes a distinctive range of colours from yellow to greenish blue to develop
Ammonia, Marine Range0.00 to 2.50 ppm (as NH₃)
Ammonia, Marine Resolution0.01 ppm
Ammonia, Marine Accuracy±0.05 ppm ±5% of reading at 25°C
Ammonia, Marine MethodAdaptation of the Salicylate Method
Ammonia, Marine LED610 nm
Calcium, Marine Range200 to 600 ppm
Calcium, Marine Resolution1 ppm
Calcium, Marine Accuracy±6 % of reading at 25 °C
Calcium, Marine MethodAdaptation of the Zincon Method
Marine Magnesium
Range1000 to 1800 ppm (as Mg 2+ )
Resolution5 ppm
Accuracy±5% of reading at 25 °C
MethodAdaptation of the Colorimetric EDTA Method using calmagite indicator
LED610 nm
Nitrate Range0.00 to 5.00 ppm (as No3¯) 0.0 to 75.0 ppm (as No3¯)
Nitrate Resolution0.01 ppm 0.1 ppm
Nitrate Accuracy0 to 200 ppb (as No2¯-N)
Nitrate MethodAdaptation of the Zincon Method Colorimetric Method The reaction between nitrate and the reagent causes a pink/violet tint in the sample.
Nitrite, Marine LR Range0 to 800 ppb (as No2¯-N)
Nitrite, Marine LR Resolution1 ppb
Nitrite, Marine LR Accuracy±10 ppb ±4 % of reading at 25 °C
Nitrite, Marine LR MethodAdaptation of the EPA Diazotization Method 354.1 - The reaction between nitrite and the reagent causes a pink tint in the sample.
pH Range6.3 to 8.6 pH
pH Resolution0.1 pH
pH Accuracy±0.2 pH of reading at 25°C
pH MethodColorimetric Adaptation of the Phenol Red Method
Phosphate, ULR Range0.00 to 0.90 ppm
Phosphate, ULR Resolution0.01 ppm
Phosphate, ULR Accuracy±0.02 ppm ±5 % of reading at 25 °C
Phosphate, ULR MethodAdaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method - The reaction between phosphate and the reagent causes a blue tint in the sample.
Light Sourcelight emitting diode
Light DetectorSilicon photocell
Bandpass Filter Bandwidth8 nm
Bandpass Filter Wavelength Accuracy±1.0 nm
Logging200 readings
Power Supply1.5 V AA Alkaline (3 pcs.)
Battery Life> 800 measurements (without backlight)
Auto-offAfter 15 minutes of inactivity (30 minutes before a READ measurement)
Environment0 to 50 °C (32 to 122 °F); 0 to 100% RH, non serviceable
Dimensions142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0")
Weight380 g (13.4 oz.); with batteries
Warranty2 years
Reagent sets
HI-758‑26Marine Calcium Reagent - 25 tests
HI-767‑25Marine Nitrite LR Reagent - 25 tests
HI-772‑26Marine Alkalinity Reagent - 25 tests
HI-774‑25Marine Phosphate ULR Reagent - 25 tests
HI-780‑25Marine pH Reagent - approximately 100 tests
HI-781‑25Marine Nitrate LR Reagent - 25 tests
HI-782‑25Marine Nitrate HR Reagent - 25 tests
HI-783-25Marine Magnesium Reagents - 25 tests
HI-784-25Marine Ammonia Reagent - 25 tests
HI-97105‑11CAL Check™ standards for HI-97105 - cuvette kit
Other Accessories
HI-70436MDeionized water (230 mL)
HI-7101418Blue carrying case for HI-97105C
HI-731318Cloth for wiping cuvettes (4 pcs.)
HI-731331Glass cuvette (4 pcs.)
HI-731360Glass cuvette with cap (2 pcs.)
HI-731336NCap for glass cuvette (4 pcs.)
HI-731339P0.1 mL mini pipette
HI-731349PTip for 0.1 mL mini pipette (10 pcs.)
HI-740142P1 mL graduated syringe (10 pcs.)
HI-7401431 mL graduated syringe (6 pcs.)
HI-740144PPlastic tip for 5 mL syringe (10 pcs.)
HI-740157PPlastic refilling pipette (20 pcs.)
HI-7402265 mL graduated syringe (1 pc.)
HI-740228Filter disc (25 pcs.)
HI-74027010 mL syringe with Luer Lock (1 pc.)
HI-740271Filter holder with Luer Lock (1 pc.)
HI-74027216 gauge blunt needle (6 pcs.)
HI-740273Marine Nitrate LR measurement kit (1 pc.)
HI-93703‑50Cuvette cleaning solution (230 mL)

Accessories

  • HI-731331: HI-731331 Glass Cuvettes for Photometers and Turbidity Meters
  • HI-758-26: HI-758-26 Reagents for HI-758 Marine Calcium Checker (25 tests)
  • HI-772-26: HI-772-26 Seawater/Marine alkalinity (dKH), colorimetric method, Reagents for 25 tests
  • HI-774-25: HI-774-25 Reagents for the HI-774 Marine phosphate ULR Checker HC Colorimeter, 25 tests
  • HI-780-25: HI-780-25 Marine pH Checker Reagents, 100 tests
  • HI-781-25: HI-781-25 Marine Low Range Nitrate reagents, 25 tests
  • HI-782-25: HI-782-25 Marine High Range Nitrate Checker Reagents
  • HI-783-25: HI-783-25 Marine Magnesium reagent - 25 tests
  • HI-784-25: HI-784-25 Marine Ammonia reagent - 25 tests
  • HI-97105-11: HI-97105-11 CAL Check™ standards for HI-97105 Cuvette Kit
  • HI-731336N: HI-731336N Cuvette Caps x4 for HI-731331
  • HI-767-25: HI-767-25 Marine Nitrite Low Range Reagents - 25 tests