Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI97115C

HI97115C
Marine Master Waterproof Wireless Multiparameter Photometer Kit
HI-97115C Marine Master Waterproof Wireless Multiparameter Photometer Kit For use in aquariums and marine biology applications, this meter measures Marine pH, Alkalinity, Ammonia, Calcium, Magnesium,

Overview

HI-97115C Marine Master Waterproof Wireless Multiparameter Photometer Kit For use in aquariums and marine biology applications, this meter measures Marine pH, Alkalinity, Ammonia, Calcium, Magnesium, Nitrate Low Range, Nitrite Low Range, and Phosphate Ultra Low Range. The kit contains: HI-97115 photometer Carrying case Sample cuvettes x 2 Sample caps x 2 Marine pH reagent - 30mL dropper x 1 Marine Alkalinity reagent – 30ml bottle x 1 Marine Ammonia starter kit – reagent A and C - 1 of each x 30ml dropper, plus reagent B x 25 tests Marine Calcium starter kit – Reagent A 30ml bottle, reagent B x 25 tests Marine Magnesium starter kit – reagent A 120ml bottle, Magnesium indicator reagent x 25 tests Marine Nitrate High Range reagent x 25 tests Marine Nitrite LR reagent x 25 tests Marine phosphate ULR x 25 tests 1mL graduated syringe with tip x 2 Mini-pipette with tip x 1 3 ml Pasteur pipette x 2 5mL syringe and tip x 1 5ml syringe (blue printing) with tip x 1 1.5V AA alkaline batteries x 3 Cloth for wiping cuvettes Scissors Instrument quality certificate Quick reference guide (Please note: not all reagents and the Cal Check standard are included in this kit, so check your testing requirements are covered when ordering. See specification table to choose further reagents.

Additional costs apply.) Please download the Safety Datasheet(s) which provide more detail on the reagents before use; click on the link in the “safety data sheets” paragraph below. About the photometer The HI-97115 can be used as a stand-alone photometer or can be connected to the Hanna Lab App with a compatible smart device via the integrated Bluetooth module. When connected, Hanna Lab App functions include measurement with the ability to add notes, data logging with extended storage capacity, data sharing, and the ability to create and save method groups.

Key features Backlit LCD – The 128 x 64 pixel LCD allows for a simplified user interface Battery status indicator and auto-shut off – The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order to conserve battery life Method and parameter – Chosen parameter and method used are displaying along with the reading Large cuvette size – The sample cell fits a round glass cuvette with a 25mm path length. This allows the light to pass through more of the sample ensuring accurate measurements even in low absorbance samples. The cuvette holder features ridges to protect scratching of the optical path by the cuvette.

Virtual keys Compact size – Measures 142.5mm x 102.5mm and 50.5mm thick. Menu available at the touch of a button Dedicated help key – this provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help. Hanna Lab App When the photometer is paired with a compatible smart device, it adds an enhanced user experience to the photometer.

You can name samples and add notes, view logged detail such as date and time, share logged data in various formats, and control meter settings. More key features: Waterproof and floats – IP67 meter design Option to select measurement location for better tracking consistency CAL Check TM validation and calibration – step-by-step screen guides through the validation process and user calibration. GLP data displays the last calibration date.

Backlit LCD and on-screen help Built-in reaction timer that ensures consistency between tests On-screen tutorial mode with animations – this includes steps required for sample preparation, the required reagents and quantities. Enabled via the setup menu. Auto-data logging features to easily record water testing results – up to 200 individual measurements (data points).

When the log is full, the instruments rewrites the oldest data point Positive locking system ensures cuvettes are placed into the holder in the same position every time HI-97115 is supplied with sample cuvette (2pcs), sample cuvette caps (2pcs), 1.5V AA alkaline batteries (3 pcs), instrument quality certificate, and quick reference guide. Cal Check standards and reagents are sold separately. Safety Data Sheets Access safety data sheets online here.

When using any form of chemical, it is important you download the relevant safety datasheet and make yourself aware of any precautions you should take when handling the chemical. You can access our library of safety datasheets and download a copy by following the link below. Please note that the '-' in HI- products should be removed from all searches to find the correct information.

click here

Specifications

ParameterValue
SKUHI97115C
Alkalinity, Marine Range0.0 to 20.0 dkH 0 to 357 ppm (as CaCo 3 )
Alkalinity, Marine Resolution0.1 dkH
Alkalinity, Marine Accuracy±0.3 dKH ±5 % of reading at 25 °C ±5 ppm ±5 % of reading at 25 °C
Alkalinity, Marine MethodColorimetric Method - The reaction causes a distinctive range of colours from yellow to greenish blue to develop
Ammonia, Marine Range0.00 to 2.50 ppm (as NH₃)
Ammonia, Marine Resolution0.01 ppm
Ammonia, Marine Accuracy±0.05 ppm ±5% of reading at 25°C
Ammonia, Marine MethodAdaptation of the Salicylate Method
Ammonia, Marine LED610 nm
Calcium, Marine Range200 to 600 ppm
Calcium, Marine Resolution1 ppm
Calcium, Marine Accuracy±6 % of reading at 25 °C
Calcium, Marine MethodAdaptation of the Zincon Method
LED610nm
Marine Magnesium
Range1000 to 1800 ppm (as Mg 2+ )
Resolution5 ppm
Accuracy±5% of reading at 25 °C
MethodAdaptation of the Colorimetric EDTA Method using calmagite indicator
Nitrate Range0.00 to 5.00 ppm (as No3¯) 0.0 to 75.0 ppm (as No3¯)
Nitrate Resolution0.01 ppm
Nitrate Accuracy±0.25 ppm ±2% of reading at 25°C
Nitrate MethodZinc reduction method
Nitrite, Marine LR Range0 to 800 ppb (as No2¯-N)
Nitrite, Marine LR Resolution1 ppb
Nitrite, Marine LR Accuracy±10 ppb ±4 % of reading at 25 °C
Nitrite, Marine LR MethodAdaptation of the EPA Diazotization Method 354.1 - The reaction between nitrite and the reagent causes a pink tint in the sample.
Marine pH Range6.3 to 8.6 pH
pH Resolution0.1 pH
pH Accuracy±0.2 pH of reading at 25°C
pH MethodColorimetric Adaptation of the Phenol Red Method
Phosphate, ULR Range0.00 to 0.90 ppm
Phosphate, ULR Resolution0.01 ppm
Phosphate, ULR Accuracy±0.02 ppm ±5 % of reading at 25 °C
Phosphate, ULR MethodAdaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method - The reaction between phosphate and the reagent causes a blue tint in the sample.
Light Sourcelight emitting diode (LED)
Light DetectorSilicon photocell
Bandpass Filter Bandwidth8 nm
Bandpass Filter Wavelength Accuracy±1.0 nm
Logging200 readings
Power Supply1.5 V AA Alkaline (3 pcs.)
Battery Life> 800 measurements (without backlight)
Auto-offAfter 15 minutes of inactivity
Environment0 to 50 °C (32 to 122 °F); 0 to 100% RH, non serviceable
Dimensions142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0")
Weight380 g (13.4 oz.); with batteries
CasingIP67 rated, floats
Warranty2 years
Reagent sets
HI-758‑26Marine Calcium Reagent - 25 tests
HI-767‑25Marine Nitrite LR Reagent - 25 tests
HI-772‑26Marine Alkalinity Reagent - 25 tests
HI-774‑25Marine Phosphate ULR Reagent - 25 tests
HI-780‑25Marine pH Reagent - approximately 100 tests
HI-781‑25Marine Nitrate LR Reagent - 25 tests
HI-782‑25Marine Nitrate HR Reagent - 25 tests
HI-783-25Marine Magnesium Reagents - 25 tests
HI-784-25Marine Ammonia Reagent - 25 tests
HI-97105‑11CAL Check™ standards for HI-97105 & HI-97115 - cuvette kit
Other Accessories
HI-70436MDeionized water (230 mL)
HI-7101419Blue carrying case for HI-97115
HI-731318Cloth for wiping cuvettes (4 pcs.)
HI-731360Glass cuvette with cap (2 pcs.)
HI-74027010 mL syringe with Luer Lock (1 pc.)
HI-740271Filter holder with Luer Lock (1 pc.)
HI-74027216 gauge blunt needle (6 pcs.)
HI-740273Marine Nitrate LR measurement kit (1 pc.)
HI-740228Filter disc (25 pcs)
HI-93703‑50Cuvette cleaning solution (230 mL)

Accessories

  • HI-758-26: HI-758-26 Reagents for HI-758 Marine Calcium Checker (25 tests)
  • HI-772-26: HI-772-26 Seawater/Marine alkalinity (dKH), colorimetric method, Reagents for 25 tests
  • HI-774-25: HI-774-25 Reagents for the HI-774 Marine phosphate ULR Checker HC Colorimeter, 25 tests
  • HI-780-25: HI-780-25 Marine pH Checker Reagents, 100 tests
  • HI-781-25: HI-781-25 Marine Low Range Nitrate reagents, 25 tests
  • HI-782-25: HI-782-25 Marine High Range Nitrate Checker Reagents
  • HI-783-25: HI-783-25 Marine Magnesium reagent - 25 tests
  • HI-784-25: HI-784-25 Marine Ammonia reagent - 25 tests
  • HI-97105-11: HI-97105-11 CAL Check™ standards for HI-97105 Cuvette Kit
  • HI-767-25: HI-767-25 Marine Nitrite Low Range Reagents - 25 tests

Manuals and documentation