Overview
HI-97107 Disinfectants Portable Photometer with CAL Check - meter only This multi-functional photometer is ideal for monitoring in the following industries: Legionella control and compliance for risk assessments, monitoring, and disinfectants Potable Biocides in spas, pools and drinking water Drinking water and wastewater Water tanks Hot and cold water systems Cooling towers and systems Papermills Water feature maintenance Food manufacturing – cleaning lines Holiday Parks Hospitality Hospitals Temporary water supplies eg: events Facilities management The HI-97107 is a multiparameter portable photometer designed specifically to meet the needs of Legionella compliance and control. Benefiting from Hanna’s years of experience as a manufacturer of analytical instruments it features the Hanna CAL Check™ functionality for maximum accuracy and the unique to Hanna built-in tutorial mode. The highly accurate optical system is sealed from outside dust, dirt and water with an exclusive positive-locking system to ensure that the cuvettes are placed into the holder in the same position every time.
With the CAL Check™ functionality, users can validate the performance of the instrument at any time and apply a user calibration (if necessary). Hanna Instruments CAL Check™ cuvettes are made with NIST traceable standards. The built-in tutorial mode guides users step-by-step through the measurement process.
It includes all steps required for sample preparation, the required reagents and quantities. About the seven parameters Bromine Bromine is a powerful water disinfectant, particularly effective in hot water (treatment of pools and spas). Bromine can act as an alternative to chlorine.
The method for bromine is an adaptation of Standard Methods for the Examination of Water and Wastewater, DPD Method. Chlorine Chlorine is a widely used disinfectant. In order for it to be effective, the pH of the water should be less than 8.0.
The method for chlorine is an adaptation of US EPA Method 330.5, DPD Colorimetric Method. The method for pH is an adaptation of the Phenol Red Method. Chlorine Dioxide Chlorine Dioxide is a powerful and selective disinfectant used in water treatment across a broad pH range.
ide is an adaptation of Standard Methods for the Examination of Water and Wastewater, 18th Ed., 4500 ClO₂ D. Hydrogen Peroxide Hydrogen Peroxide is an environmentally friendly, broad spectrum disinfectant. The method for hydrogen peroxide is an adaptation of German Standard Methods for the Examination of Water and Wastewater DIN 38409-15.
Ozone Ozone is a widely used disinfectant in the treatment of drinking water, wastewater and swimming pools. The method for ozone is the DPD Colorimetric Method. About the Photometer Waterproof casing The casing offers IP67 waterproof protection and floats.
Backlit graphic LCD The 128 x 64 pixel backlit graphic LCD allows for an intuitive user interface with virtual keys, battery status, and on-screen help and tutorials to guide the user through use of the meter. Positive locking system The Hanna positive-locking system ensures cuvettes are placed into the holder in the same position every time. Virtual Keys Menu available at the touch of a button Dedicated HELP button A dedicated help key provides informational help relating to the current meter operation, and can be used at any stage in the setup or measurement process.
Our advanced LED optical system features 8 nm narrow band interference filter that is accurate to ±1 nm and offers a 25% increase in light efficiency over conventional filters A reference detector that modulates the voltage to the LED for consistent light output A concave focusing lens that reduces errors from imperfections in the cuvette High efficiency light source LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.
High quality filters High tolerance optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received providing higher measurement stability and repeatability. Stable light source The internal reference system of Hanna photometers compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light, the readings are fast and reliable between blank (zero) measurements and sample measurements.
Greater light yield A focusing lens collects all of the light that exits the cuvette, reducing errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes. Large cuvette size The sample cell of these photometers fits a round, glass cuvette with a 25 mm path length.
The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples. The cuvette holder features ridges to protect scratching of the optical path by the cuvette. Key features Method and parameter Chosen parameter and method used is displayed along with the reading.
Multiple measurement methods Method selection can be accessed by pressing the menu button and selecting Methods. Use the function keys to highlight the desired method. Auto logging Log and recall the last 50 measurements.
Built-in reaction timer Waiting for the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between sample measurements and users. CAL Check™ functionality Hanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards.
Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings. The CAL Check screen guides the user step-by-step through the validation process and user calibration. GLP data Good Laboratory Practice (GLP) shows the date and time of the last user calibration.
Setup options Setup options for meter personalization include date and time format, language, and enabling the tutorial mode. Auto-off protection Supplied with 3 x standard AA batteries provides power 800 measurements to be taken. Our batter preserving auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.
Battery status indicator indicates the amount of battery life left. Dedicated help A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help. On-screen tutorial mode with animations The built in tutorial mode guides users step-by-step through the measurement process.
Error messages Messages appear on the display alerting to problems such as out of range, light low, light high, ambient temperature out of limits, and battery low. HI-97107 What's included: Each HI-97107 is delivered is supplied with: Sample cuvette with cap (2 pcs.) Plastic stopper (2 pcs.) 1.5V AA alkaline battery (3 pcs.) Battery safety insert Quick reference guide with instructions for manual download and instrument quality certificate. Warranty 2 Years meter Accessories – to buy separately Standards HI-97107-11 CAL Check™ Validation and Calibration Standards Cuvette Kit.
Reagents HI-96795-01 Hydrogen Peroxide reagents for 100 tests HI-96795-03 Hydrogen Peroxide reagents for 300 tests HI-93701-F Free Chlorine reagent for 300 tests (liquid) HI-93701-T Total Chlorine reagent for 300 tests (liquid) HI-93703-52 Glycine powder reagent for 100 tests HI-93710-01 pH reagent for 100 tests HI-93710-03 pH reagent for 300 tests HI-93716-01 Bromine reagent for 100 tests HI-93716-03 Bromine reagent for 300 tests HI-93757-01 Ozone reagent for 100 tests HI-93757-03 Ozone reagent for 300 tests HI-95771-01 Total Chlorine UHR reagent for 100 tests HI-95771-03 Total Chlorine UHR reagent for 300 tests HI-96779-01 Chlorine Dioxide (Rapid) reagent for 100 tests HI-96779-03 Chlorine Dioxide (Rapid) reagent for 300 tests Other HI-7101422 Blue carrying case HI-731318 Cloth for wiping cuvettes (4 pcs.) HI-731331 Glass cuvette (4 pcs.) HI-731336N Cap for glass cuvette (4 pcs.) HI-740034P Cap for 100 mL beaker (10 pcs.) HI-740036P 100 mL plastic beaker (10 pcs.) HI-740143 1 mL graduated syringe (6 pcs.) HI-740144P Pipette tip for 1 mL graduated syringe (10 pcs.)
Specifications
| Parameter | Value |
|---|---|
| SKU | HI97107 |
| Bromine | |
| Range | 0.00 to 10.00 mg/L (as Br₂) |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.08 mg/L ±3% of reading at 25 °C (77 °F) |
| Method | Adaptation of Standard Methods for the Examination of Water and Wastewater, 18th Edition, DPD Method |
| Free and Total Chlorine LR | |
| Accuracy* | ±0.03 mg/L ±3% of reading at 25 °C (77 °F) |
| Calibration | Adaptation of US EPA Method 330.5, DPD Colorimetric Method |
| Total Chlorine UHR | |
| Chlorine Dioxide (Rapid) | |
| Hydrogen Peroxide | |
| Ozone | |
| pH | |
| Measurement System | |
| Light source | Light Emitting Diode |
| Bandpass filter | 525 nm |
| Bandpass filter bandwidth | 8 nm |
| Bandpass filter wavelength accuracy | ±1.0 nm |
| Light detector | Silicon photocell |
| Cuvette type | Round 24.6 mm diameter (22 mm inside) |
| Additional specifications | |
| Auto logging | 50 readings |
| Display | 128 x 64 pixel black and white LCD with backlight |
| Auto-off | After 15 minutes of inactivity (30 minutes before a READ measurement) |
| Battery type | 1.5 V AA Alkaline (3 pcs.) |
| Battery life | More than 800 measurements (without backlight) |
| Environment | 0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable |
| Dimensions | 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0") |
| Weight (with batteries) | 380 g (13.4 oz.) |
| Case ingress protection rating | IP67, floating case |
Accessories
- HI-93701-T: HI-93701-T Total Chlorine Liquid Reagent - 300 tests
- HI-93701-F: HI-93701-F Chlorine (Free) Liquid Reagents for 300 tests
- HI-93710-01: HI-93710-01 pH Reagent, Phenol Red Method, 100 tests
- HI-93710-03: HI-93710-03 pH Reagents, Phenol Red method, 300 pH tests
- HI-93716-01: HI-93716-01 Bromine Reagent, DPD Method
- HI-93716-03: HI-93716-03 Reagents for 300 bromine tests
- HI-93757-01: HI-93757-01 Ozone Reagent, DPD Method
- HI-95771-01: HI-95771-01 UHR Chlorine Reagents, 100 tests
- HI-95771-03: HI-95771-03 UHR Chlorine Reagent set of 300 tests
- HI-96779-01: HI-96779-01 Chlorine Dioxide Rapid Method Reagents for 100 tests
- HI-96795-01: HI-96795-01 Hydrogen Peroxide Reagents, 100 tests
- HI-96795-03: HI-96795-03 Hydrogen Peroxide Reagents, 300 tests
Related Products
HANNA InstrumentsEPA Compliant Turbidity and Free & Total Chlorine Meter
HANNA InstrumentsHardness, High Range Test Kit
HANNA InstrumentsAlkaline battery size AAA
Large pump head assembly
HANNA InstrumentsRugged Case for Waterproof Meters with Moulded Insert
HANNA InstrumentsAuger for Ground Penetration
HANNA InstrumentsChromium VI High Range Handheld Colorimeter - Checker HC
HANNA Instruments