Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI97115

HI97115

Seawater multiparameter photometer

Multiparameter photometer

Product Overview

  • HI97115 is a compact, multi-parameter marine photometer designed for the accurate determination of pH, seawater alkalinity, ammonia, calcium, magnesium, nitrate, nitrite, and phosphate in aquarium and marine biology applications. Suitable for field or laboratory use. HI97115 can be used as a standalone photometer or connected to the Hanna Lab App via a compatible smart device through the integrated Bluetooth module. When connected, the Hanna Lab App features include measurement with annotations, data logging with expanded storage capacity, data sharing, and the ability to create and save method groups. Main applications: marine, seawater aquariums, aquaculture   

  • Precise and advanced LED optical system. 

  • Waterproof IP67 

  • Uses CAL CheckTM calibration certification 

  • Includes automatic data logging for up to 200 measurement results. 

  • On-screen tutorial mode guides the user step by step through the measurement process. 

  • Assign location to recorded readings 

  • Positive locking system ensures the cuvette is placed in the correct position every time 

  • Compatible with HANNA cloud storage

pH pH

Range

6.3 – 8.6 pH

Seawater Nitrate HR

Range

0.0 – 75.0 ppm

Resolution

0.1 Ph

 

Resolution

0.1 ppm

Accuracy@250C

±0.2pH

 

Accuracy@250C

±5%±2.0ppm of reading

Method

Colorimetric adaptation of the phenol red method

 

Method

Zinc reduction method

LED

525 nm

 

LED

525 nm

Seawater Alkalinity

Range

0.0 – 20.0 dkH

Seawater Nitrite ULR

Range

0 – 200 ppb(NO2-N)

Resolution

0.1 dkH

 

Resolution

1 ppb

Accuracy@250C

±5% ±0.3 dkH of reading

 

Accuracy@250C

±4%±10ppb of reading

Method

Colorimetric method

 

Method

Adaptation of EPA diazotization method 354.1 

LED

610 nm

 

LED

525 nm

Seawater Ammonia

Range

0.00 – 2.50 ppm (NH3)

Seawater Phosphate ULR

Range

0.00 – 0.90 ppm

Resolution

0.01 ppm

 

Resolution

0.01 ppm

Accuracy@250C

±0.05ppm 5% of reading

 

Accuracy@250C

±5%±0.02ppm of reading

Method

Adaptation of the salicylate method

 

Method

Ascorbic acid method

LED

610 nm

 

LED

610 nm

Seawater Calcium

Range

200 – 600 ppm

Measurement System

Light Source

LED

Resolution

1 ppm

 

Bandpass Filter

Wavelength 525nm&610 nm

Accuracy@250C

±6% of reading

Bandwidth 8nm

Method

Adaptation of the Zincon method

Wavelength Accuracy ±1.0 nm

LED

610 nm

 

Light Detector

Silicon photocell

Seawater Magnesium

Range

1000 – 1800 ppm(Mg2+)

 

Cuvette Specifications

Approx. 24.6 mm&22mm

Resolution

5 ppm

Other Information

Automatic Storage

200 measurement records

Accuracy@250C

±5% of reading

 

Display

128 x 64 LCD with backlight

Method

Adaptation of the EDTA colorimetric method

 

Auto Shut-off

After 15 minutes of non-use

LED

610 nm

 

Battery

Alkaline battery 1.5 V AA(3), more than 800 hours without backlight.

Seawater Nitrate LR

Range

0.00 – 5.00 ppm(NO3-)

 

Operating Environment             0 – 500C , 0 – 100% RH, non-condensing

Resolution

0.01 ppm

 

Dimensions/Weight            142.5 x 102.5 x 50.5 mm , 380g

Accuracy@250C

±2%±0.25ppm of reading

 

Protection Class             IP67 floating rating

Method

Zinc reduction method

Standard Configuration

Meter, 2 cuvettes and caps, 1.5VAA alkaline batteries (3pcs), instruction manual, quality certificate

LED

525 nm

Meter, 2 cuvettes and caps, 1.5V AA alkaline batteries (3pcs), instruction manual, quality certificate    

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.