Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI97713C

HI97713C
Phosphate Low Range Portable Photometer Kit
HI-97713C kit is supplied with a meter, CAL Check cuvette A, CAL check cuvette B for phosphate LR, sample cuvettes (2), sample caps (2), plastic stoppers (2), 1.5 V AA batteries (3), cuvette wiping cl

Overview

HI-97713C kit is supplied with a meter, CAL Check cuvette A, CAL check cuvette B for phosphate LR, sample cuvettes (2), sample caps (2), plastic stoppers (2), 1.5 V AA batteries (3), cuvette wiping cloth, scissors, instrument quality certificate, instruction manual and rigid carrying case. The HI-97713 is an advanced portable photometer for the measurement of low range phosphate in water. This meter offers a superior optical system that utilises a reference detector and narrow band interference filters for extremely fast and repeatable measurements.

Measurement method: Adaptation of the Ascorbic Acid method. Range: 0.00 to 2.50 mg/L (as PO 4 3- ) Advanced LED optical system – LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.

CAL Check™ - Validate the performance of the instrument at any time and apply a user calibration using CAL Check cuvettes made with NIST traceable standards. The CAL Check screen guides the user step-by-step through the validation process and user calibration. Auto logging GLP – Review of the last calibration date On-screen tutorial mode with animations – the built in tutorial mode guides users step-by-step through the measurement process.

Waterproof and floating IP67 case Auto-shut off – Automatic shut off after 15 minutes of inactivity and 30 minutes before a read measurement. Battery status indicator – Indicates the amount of battery life left. Built-in timer – Display of time remaining before a measurement is taken.

Ensures that all readings are taken at the appropriate reaction intervals for the test being performed. Error messages – Messages on display alerting to problems including no cap, high zero, and standard too low. Unit of measure – Appropriate unit of measure is displayed along with reading.

Specifications

ParameterValue
SKUHI97713C
Range0.00 to 2.50 mg/L (as PO 4 3- )
Resolution0.01 mg/L
Accuracy @25°C±0.04 mg/L ±4% of reading at 25°C
MethodAdaptation of the Ascorbic Acid Method
Light Sourcelight emitting diode
Bandpass filter610nm
Bandpass filter bandwidth8nm
Bandpass filter wavelength accuracy±1.0nm
Light DetectorSilicon photocell
Cuvette typeRound 24.6mm diameter (22mm inside)
Auto logging50 readings
Display128 x 64 pixel B/W LCD with backlight
Auto-offAfter 15 minutes of inactivity (30 minutes before a READ measurement)
Battery type/lifeAlkaline 1.5 V AA (3)/ >800 measurements (without backlight)
Environment0 to 50°C; 0 to 100% RH
Dimensions142.5 x 102.5 x 50.5 mm
Weight380g
Ordering informationHI-97713 is supplied with sample cuvettes (2), sample caps (2), plastic stoppers (2), 1.5V AA batteries (3), instrument quality certificate and instruction manual. Available as a kit: HI-97713C includes photometer, CAL Check cuvette A & B for phosphate LR, sample cuvettes (2), sample caps (2), plastic stoppers (2), 1.5V AA batteries (3), cuvette wiping cloth, scissors, instrument quality certificate, instruction manual and rigid carrying case.

Accessories

  • HI-731318: HI-731318 Cuvette Cleaning Cloths x 4
  • HI-93713-01: HI-93713-01 Phosphate Low Range Reagent
  • HI-93713-03: HI-93713-03 Phosphate LR reagents, Ascorbic Acid Method
  • HI-97713-11: HI-97713-11 Phosphate Low Range CAL Check standard

Manuals and documentation