Overview
HI-97757C Ozone Portable Photometer Kit The HI-97757 photometer measures ozone in water samples from 0.00 to 2.00 mg/L (ppm) using the DPD Colorimetric Method. Ozone is a widely used disinfectant in the treatment of drinking water, wastewater and swimming pools. Suitable for field or bench measurements.
About the Ozone Portable Photometer The HI-97757 is an auto-diagnostic Ozone portable photometer with an advanced optical system that uses a Light Emitting Diode (LED), and a narrow band interference filter that allows for accurate and repeatable readings. The optical system is sealed from outside dust, dirt and water. The meter uses an exclusive positive locking system to ensure that the cuvettes are placed into the holder in the same position every time.
With the CAL Check™ functionality, users can validate the performance of the instrument at any time and apply a user calibration (if necessary). Hanna Instruments CAL Check cuvettes are made with NIST traceable standards. The built-in tutorial mode guides users step-by-step through the measurement process.
It includes all steps required for sample preparation, the required reagents and quantities. The ozone photometer features: Sophisticated optical system Waterproof IP67, floating case Backlit LCD The 128 x 64 Pixel LCD allows for a simplified user interface. Meter validation using certified CAL Check cuvettes Good Laboratory Practice (GLP) features Tutorial mode guides the user step-by-step Includes auto-data logging features to easily record water testing results Battery status indicator and auto-shut off after 15 minutes Compact size - Measures 142.5 mm (5.6”) x 102.5 mm (4”) and only 50.5 mm (2”) thick.
Battery status indicator and auto-shut off The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life. Measurement on large, backlit LCD display Parameter and concentration used is displayed along with the reading. Positive locking system The Hanna positive-locking system ensures cuvettes are placed into the holder in the same position every time.
CAL Check™ validation Validate instrument performance at any time using CAL Check cuvettes made with NIST traceable standards. Reaction timer Displays time remaining before a measurement is taken. Ensures that all readings are taken at the appropriate intervals for the test being performed.
Setup menu available at the touch of a button Setup options for meter personalisation include date and time format, language, and enabling the tutorial mode. Auto-data logging Data autolog helps users keep track of all measurements. Data is automatically saved every time a measurement is made.
The data log can hold 200 individual measurements. When the data log is full, the meter will rewrite the oldest data point. Waterproof and floating, IP67 meter design Dedicated help The dedicated help key provides information relating to current meter operation.
It can be used at any stage in the setup or measurement process.
Specifications
| Parameter | Value |
|---|---|
| SKU | HI97757C |
| Buy as a kit – HI-97757C includes: | A rugged carrying case, supplied with sample cuvette (2 pcs.), sample cuvette cap (2 pcs.), plastic stopper (2 pcs.), A ZERO - CAL Check™ Cuvette A, HI97757B - CAL Check Cuvette B for Ozone, cloth for wiping cuvettes, scissors, 1.5V AA Alkaline battery (3 pcs.), CAL Check standard certificate, battery safety insert, quick reference guide with instructions for manual download, and instrument quality certificate. Other reagents sold separately. |
| Ozone | |
| Range | 0.00 to 2.00 mg/L (as O₃) |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.02 mg/L ±3% of reading at 25 °C |
| Method | DPD Colorimetric Method |
| Measurement system | |
| Light source | Light Emitting Diode |
| Bandpass filter | 525 nm |
| Bandpass filter bandwidth | 8 nm |
| Bandpass filter wavelength accuracy | ±1.0 nm |
| Light detector | Silicon photocell |
| Cuvette type | Round 24.6 mm diameter (22 mm inside) |
| Additional specifications | |
| Auto logging | 50 readings |
| Display | 128×64 pixel B/W LCD with backlight |
| Auto-off | After 15 minutes of inactivity (30 minutes before a read measurement) |
| Battery type | 1.5 V AA Alkaline (3 pcs.) |
| Battery life | more than 800 measurements (without backlight) |
| Environment | 0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable |
| Dimensions | 142.5×102.5×50.5 mm (5.6×4.0×2.0") |
| Weight (with batteries) | 380 g (13.4 oz.) |
| Case ingress protection rating | IP67, floating case |
| Reagents sold separately: | Reagents and standards HI-97757-11 CAL Check™ Standards for Ozone; HI-93757-01 Ozone Reagent - 100 tests; HI-93757-03 Ozone Reagent - 300 tests; HI-93703-52 Glycine Powder Reagent - 100 tests; Accessories HI-7101412; HI-977 series blue carrying case with 2 cuvette slots; HI-731318 Cloth for wiping cuvettes (4 pcs.); HI-731331 Glass cuvette (4 pcs.); HI-731336N Cap for glass cuvette (4 pcs.); HI-731360 Glass cuvette with cap (2 pcs.); HI-93703-50 Cuvette cleaning solution (250 mL). |
Accessories
- HI-731318: HI-731318 Cuvette Cleaning Cloths x 4
- HI-93703-50: HI-93703-50 Cuvette Cleaning Solution, 230ml
- HI-93757-01: HI-93757-01 Ozone Reagent, DPD Method
Related Products
HANNA InstrumentsEPA Compliant Turbidity and Free & Total Chlorine Meter
HANNA InstrumentsHardness, High Range Test Kit
HANNA InstrumentsAlkaline battery size AAA
HANNA InstrumentsSyringe 10mL with Luer Lock
Large pump head assembly
HANNA InstrumentsRugged Case for Waterproof Meters with Moulded Insert
HANNA InstrumentsAuger for Ground Penetration
HANNA Instruments