Product Overview
HI9812-5 is a multi-functional, waterproof, multi-parameter, portable meter, using the HI1285-5 electrode. The electrode features a unique DIN connector design and gel electrolyte, making it suitable for routine, greenhouse, hydroponics, water treatment, agriculture, boiler, cooling tower and other sample measurements. The meter features an oversized backlit LCD display that shows measurement parameters and calibration indicators. Calibration can be easily performed using the knobs on the panel. Hanna's unique CAL CHECK TM calibration verification function allows users to quickly check the calibration status of the multi-parameter electrode at any time.
-
New exterior design, oversized dual-line screen display, user-friendly design, ergonomic, good cost-effectiveness;
-
Simultaneously measures and displays pH/(EC/TDS) and ℃ measurements, with quick switching between pH, EC, and TDS;
-
Setup and calibration information prompts, manual acidity calibration, built-in 2 sets of standard calibration points; pH4.01, 7.01, 10.01 and pH4.01, 6.86, 9.18;
-
Designed for field measurement, battery replacement is simple and quick, BEPS low battery error prevention system avoids incorrect measurements;
-
Suitable for providing laboratory-grade measurement results even in harsh environments.
|
Acidity PH |
Measuring range | 0.0 to 14.0 pH | |
| Resolution | 0.1 pH | ||
| Accuracy | ±0.1 pH | ||
|
Conductivity EC |
Measuring range |
0 to 1990 μS/cm |
|
| Resolution | 10 μS/cm | ||
| Accuracy | ±2% F.S. | ||
|
Total Dissolved SolidsTDS |
Measuring range |
0 to 1990 ppm(mg/L) |
|
| Resolution | 10 ppm (mg/L) | ||
| Accuracy | ±2% F.S. | ||
|
Temperature |
Measuring range | 0.0 to 60.0℃ | |
| Resolution | 0.1℃ | ||
| Accuracy | ±0.5℃ | ||
|
Temperature compensation |
pH |
Automatic temperature compensation: -5.0 to 60.0℃(23.0 to 140.0 ℉) |
|
| EC-TDS | Compensation coefficient β=2.0% /℃ | ||
|
Other specifications |
TDS factor | 0.5ppm (mg/L)=1 μS/cm | |
| Calibration mode | pH, EC/TDS single-point calibration | ||
| Electrode type | HI1285-5 polypropylene body with built-in temperature sensor pH-EC-TDS electrode (DIN connector, 1m cable length) | ||
| Power supply type | 9V battery | ||
| Operating environment | 0℃ to 50℃(32 ℉ to 122 ℉),max 100% RH | ||
| Dimensions & weight | Dimensions: 145x80x36 mm, Weight: 230g | ||
HI9811-5 meter, HI9812-5 meter, HI1285-5 polypropylene body with built-in temperature sensor pH-EC-TDS electrode, acidity-conductivity standard buffer solution kit, Chinese and English instruction manual
Case Studies
Municipal Wastewater Treatment · Hanna — Stock Configuration Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.
Configuration
Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.
Food & Beverage · Hanna — Stock Configuration Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.
What We Did
We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Hanna — Stock Configuration Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.
Delivery Approach
Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.
Power & Energy · Hanna — Stock Configuration Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.
Implementation
The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.
Related Products
HANNA InstrumentsPortable multi-range conductivity meter
HANNA InstrumentsLow range ammonia nitrogen portable photometer
HANNA InstrumentsSaltwater aquarium salinity meter
HANNA InstrumentsPortable multi-range turbidimeter
HANNA InstrumentsPortable honey color analyzer
HANNA InstrumentsPortable free chlorine photometer
HANNA InstrumentsPortable free and total chlorine photometer
HANNA Instruments