HI98121

HI98121

Waterproof pen-type pH/ORP meter

pH and ORP meter
  • Measuring range: -2.00 to 16.00 pH, ± 1000 mV [ORP], -5.0 to 60.0°C, 23.0 to 140.0°F;

  • Suitable for field or laboratory use, simple and affordable operation, meets laboratory measurement standards.

  • Note: When using the instrument to measure HI7021 ORP standard solution, if the measured value is within @25ºC 240 mV ± 50 mV, the electrode is functioning properly. If it is not within this range, use HI7091 or HI7092 for oxidation or reduction treatment until it meets the standard.

Features a large LCD screen, automatic calibration recognition, measurement value identification, auto power-off, and other functions. User-friendly interface, stability indicator, two-button simple operation, convenient to use, 1-2 point automatic pH calibration recognition, built-in 2 sets of pH calibration standard points, ORP factory calibration, automatic temperature compensation, ensuring measurement precision and accuracy in different environments, battery level display and auto power-off. When battery power is low, a low battery indicator is displayed, prompting timely battery replacement; the instrument can be set with an 8-minute auto power-off function, suitable for providing laboratory-grade measurement results even in field environments.

New exterior design, extra-large dual-line screen display

On-screen calibration procedure prompts

User-friendly interface

  • Stability indicator, two-button simple operation, convenient to use

  • Simultaneous measurement display of pH (ORP) and °C, quick switching between pH and ORP

  • 1-2 point automatic pH calibration recognition, built-in 2 sets of pH calibration standard points: pH4.01, 7.01, 10.01 and pH4.01, 6.86, 9.18

  •  ORP factory calibration, no further calibration process required

  •  Automatic temperature compensation, ensuring measurement precision and accuracy in different environments

Quick and easy battery replacement

  • BEPS low battery error prevention system, avoiding erroneous measurements

  • Suitable for providing measurement results even in harsh environments

Measuring range pH: -2.00 to 16.00 pH,
ORP: ±1000 mV
Temperature: -5.0 to 60.0℃ (23.0 to 140.0℉)
Resolution 0.01 pH, 1 mV, 0.1℃, 0.1℉
Accuracy (@25℃) ±0.05 pH, ±2 mV, ±0.5℃, ±1℉
Calibration mode 1-2 point automatic recognition calibration, built-in 2 sets of pH calibration points
pH4.01, 7.01, 10.01 and pH4.01, 6.86, 9.18
Temperature compensation Automatic temperature compensation
Electrode configuration Direct-insertion polypropylene glass composite pH electrode
Power supply 4*1.5V button cell batteries, auto power-off after 8 minutes of no operation in measurement mode
Operating environment  -5 to 50℃ (23 to 122℉), RH max 100%
Dimensions & weight Instrument dimensions: 163*40*26mm (6.4*1.6*1.0”), instrument weight: 100g (3.5oz.)

Instrument, direct-insertion polypropylene glass composite pH electrode/ORP electrode, Chinese and English instruction manual

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.