HI9814

HI9814

Waterproof multiparameter water quality meter

Mid range pH-EC-TDS-/temperature meter

Product Overview

  • HI9814 can measure pH, conductivity, total dissolved solids, and temperature. All operations and settings can be completed with just two buttons, including calibration and temperature range setting. The meter features a waterproof housing design with IP67 protection class.

  • Waterproof interface, portable design

  • Multi-parameter electrode with built-in temperature sensor

  • Automatic temperature compensation

  • Single-point calibration for pH and EC using quick calibration solution

  • One or two pH standard calibration points, one EC standard calibration point

  • Preamplifier to avoid noise interference during pH measurement

  • Accurate data logging

  • Battery error prevention system

  • Battery level display

  • Auto power off

pH 

   pH

     Measuring range 0.00~14.00 pH (sensor set to 0~12 pH, -5~30℃)
     Resolution 0.01 pH
     Accuracy ±0.01 pH
     Calibration mode Automatic calibration, single-point or two-point calibration (4.01, 7.01, 10.01, three standard points), single-point calibration using quick calibration
     Temperature compensation Automatic temperature compensation

   Conductivity 

   EC

     Measuring range

0.00~6.00 mS/cm

     Resolution 0.01 mS/cm
     Accuracy ±2% F.S.
     Calibration mode Automatic calibration, single-point calibration at 1.41 mS/cm or 5.00 mS/cm, single-point calibration using quick calibration
     Temperature compensation Automatic compensation, β=1.9%/℃

  Total dissolved solids 

  TDS

     Measuring range

0 ~ 3000 ppm (500 CF); 0 ~ 3999 ppm (700 CF)

     Resolution 10 ppm (mg/L)
     Accuracy ±2% F.S.
     Conversion factor 0.5 (500 ppm) or 0.7 (700 ppm) (1000μS/cm=500 ppm with 0.5 CF)

   Temperature

     Measuring range 0.0 ~ 60.0℃/32.0 ~ 140.0 ℉
     Resolution 0.1℃ /0.1 ℉
     Accuracy ±0.5℃/±1 ℉

  Other specifications

     EMC standard deviation ±0.02 pH; ±0.2 ℃ or ±0.4 ℉
     Electrode type HI1285-7 pH/conductivity/TDS/temperature electrode, DIN connector, 1 m cable length
     Power supply 1.5V AAA (3) / approx. 500 hours
     Auto power off 8 minutes, 60 minutes, off
     Operating environment Temperature 0~50 ℃ (32 ~122 ℉); max. relative humidity 100%
     Dimensions/Weight Meter dimensions: 152x58x30 mm  Meter weight: 205 g

Meter, HI1285-7 pH/conductivity/TDS/temperature electrode, calibration solution and electrode cleaning solution, Chinese and English instruction manual

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.