Product Overview
-
Measuring range: 0.00 to 14.00 pH, pH-mV: ± 600.0 mV, mV/ORP: ± 2000.0 mV
-
EC: 0 to 200 mS/cm, TDS: 0.0 to 400.0 ppt (g/L), Resistivity: 0 to 1.0000 MΩ•cm
-
Salinity: 0.00 to 70.00 PSU, Seawater specific gravity: 0.0 to 50.0 σt, σ₀, σ₁₅
-
Portable high-precision professional multi-parameter analyzer, compliant with IP67 international waterproof standard, for fast and accurate measurement of 10 routine and important water quality parameters including pH, pH-mV conversion, ORP, conductivity EC, resistivity, total dissolved solids TDS, salinity, seawater specific gravity, barometric pressure, temperature, etc. [including 5 measured values and 5 calculated values], with automatic range recognition and unit conversion; new exterior design, on-screen calibration procedure prompts, GLP function, quick data query, pH check function, automatic recognition calibration and user-defined calibration, automatic endpoint locking function, USB data interface, large-capacity data storage, and good data management
-
New ergonomic design, extra-large backlight, graphical display function, and good cost performance
-
Main body IP67 waterproof and slip-resistant design, electrode IP68 waterproof standard, meeting measurement requirements in harsh environments such as pipes or deep wells
-
Multi-parameter integrated electrode design, smart electrode holder with built-in microprocessor and temperature sensor, capable of installing pH (ORP) and EC electrodes simultaneously
-
Color-coded electrode positions, easy installation, automatic recognition
-
Fast simultaneous measurement of 9 water quality parameters, full-screen display, clear at a glance
-
Unique quick calibration function, automatic error diagnosis function, automatic range recognition, easy replacement and measurement
-
Powerful GLP management, large-capacity storage of 45,000 data records, USB data interface, data analysis and management software
-
Good resistance to electromagnetic signal interference, ensuring measurement reliability, accuracy, and wide application range
|
PH pH-mV |
Measuring range | 0.00 to 14.00 pH/±600.0 mV | |
| Resolution |
0.01 PH/0.1mV |
||
| Accuracy | ±0.02 pH/±0.5 mV | ||
| Calibration mode | Up to three-point automatic recognition calibration and one user-defined calibration, with five built-in standard calibration points 4.01, 6.86, 7.01, 9.18, 10.01 pH parameters | ||
|
Oxidation-reduction ORP |
Measuring range | ±2000 mV | |
| Resolution |
0.1mV |
||
| Accuracy | ±1.0 mV | ||
| Calibration mode | Single-point user-defined calibration (relative mV) | ||
|
Conductivity |
Measuring range | 0 to 200 mS/cm (absolute conductivity up to 400 mS/cm) | |
| Resolution |
1 μS/cm, 0.001ms/cm, 0.01 mS/cm, 0.1mS/cm 1mS/cm |
||
| Accuracy | Reading ±1% or±1 mg/L (ppm), whichever is greater | ||
| Calibration mode |
Automatic recognition single-point calibration, user-defined calibration, with six built-in conductivity standard calibration points 84μS/cm, 1413μS/cm, 5.00mS/cm, 12.88mS/cm, 80.0mS/cm, 111.8mS/cm |
||
|
TDS |
Measuring range | 0 to 400000 mg/L or ppm (maximum value depends on TDS factor) | |
| Resolution |
1 mg/L(ppm), 0.001g/L (ppt), 0.01g/L (ppt), 0.1g/L (ppt), 1g/L (ppt) |
||
| Accuracy | Reading ±1% or±1 mg/L (ppm), whichever is greater | ||
| Calibration mode | Calibrated based on conductivity or salinity | ||
|
Resistivity |
Measuring range |
0 to 999999 Ω·cm; 0 to 1000.0 kΩ·cm; 0 to 1.0000 MΩ·cm; |
|
| Resolution | Depends on reading | ||
|
Calibration mode |
Calibrated based on conductivity or salinity | ||
|
Salinity |
Measuring range | 0.00 to 70.00 PSU | |
| Resolution | 0.01 PSU | ||
| Accuracy | Reading ±2% or±0.01 PUS, whichever is greater | ||
| Calibration mode | Calibrated based on conductivity | ||
|
Seawater specific gravity |
Measuring range | 0.0 to 50.0 σt,σ0,σ15 | |
| Resolution | 0.1 σt,σ0,σ15 | ||
| Accuracy | ±1.0 σt,σ0,σ15 | ||
| Calibration mode | Calibrated based on conductivity | ||
|
Temperature |
Measuring range |
-5.00 to 55.00℃; 23.00 to 131.00℉; 268.15 to 328.15K |
|
| Resolution | 0.01℃;0.01℉;0.01K | ||
| Accuracy | ±0.15℃;±0.27℉;±0.15K | ||
| Calibration mode | Single-point user calibration | ||
|
Other technical parameters |
Temperature compensation | Automatic temperature compensation, -5.00 to 55.00℃, 23.00 to 131.00℉ | |
| Data storage | 45,000 measurement data records (continuous automatic logging or manual logging) | ||
| Logging interval | Settable from 1 second to 3 hours | ||
| Data interface | USB data interface (HI9298194 data management software recommended) | ||
| Operating environment |
0 to 50℃(32 to 122 ℉);RH 100% IP67 |
||
| Battery power | 1.5V AA batteries*4, approx. 360 hours of continuous use | ||
| Weight/Dimensions |
185x93x35.2 mm (7.3x3.6x1.4“)/400g (14.2 oz) |
||
HI98195 is supplied with HI7698195 probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC sensor, HI 76981952 probe maintenance kit (sensor O-rings (5 pcs), syringe with lubricating oil, HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4 pcs), instruction manual, quick start guide, quality certificate, and a sturdy carrying case with custom thermoformed insert.
Case Studies
Municipal Wastewater Treatment · Hanna — Stock Configuration Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.
Configuration
Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.
Food & Beverage · Hanna — Stock Configuration Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.
What We Did
We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Hanna — Stock Configuration Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.
Delivery Approach
Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.
Power & Energy · Hanna — Stock Configuration Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.
Implementation
The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.
Related Products
HANNA InstrumentsPortable multi-range conductivity meter
HANNA InstrumentsLow range ammonia nitrogen portable photometer
HANNA InstrumentsPortable multi-range turbidimeter
HANNA InstrumentsSaltwater aquarium salinity meter
HANNA InstrumentsPortable honey color analyzer
HANNA InstrumentsPortable free chlorine photometer
HANNA InstrumentsPortable free and total chlorine photometer
HANNA Instruments