HI98196

Seven parameter portable water quality meter

Multiparameter meter (7 parameters)

Product Overview

  • HI98196

  • Multiparameter Meter (7 parameters)

  • The HI98196 features a new exterior design, large LCD display, backlight, on-screen operating step prompts, multiple selectable languages, and simultaneously meets the measurement of 7 important water quality analysis indicators. With IP67 excellent waterproof design and convenient and quick electrode replacement, it is the choice for field on-site measurement. The HI98196 supports continuous storage or manual storage of 45,000 data records. Customizable storage interval (1 second to 3 hours). Data transfer to PC via HI920015 USB cable and data processing software. GLP management function records calibration information in detail. Easily press the HELP key to enter the help menu and obtain on-screen help information and an introduction to the function of each key.

  • New ergonomic design, extra-large backlight, graphing display function, good cost-effectiveness

  • Main body IP67 waterproof and non-slip design, electrode IP68 waterproof standard, meeting measurement needs in harsh environments such as pipelines or deep wells

  • Multiparameter integrated electrode design, intelligent electrode holder with built-in microprocessor and temperature sensor, can simultaneously install pH (ORP) and EC electrodes

  • Color-coded electrode positions, easy installation, automatic recognition

  • Fast simultaneous measurement of 7 important water quality indicators, full-screen display, clear at a glance

  • Unique quick calibration function, automatic error diagnosis function, automatic range recognition, easy switching of measurements

  • Powerful GLP management, large-capacity 45,000 data storage function, USB data interface, professional data analysis and management software

  • Good resistance to electromagnetic signal interference, ensuring measurement reliability, accuracy, and wide applicability

Acidity 

   PH

     Measuring range

0.00 to 14.00 pH/±600.0 mV

     Resolution 0.01 pH /0.1mV
     Accuracy ±0.02 pH/±0.5mV
     Calibration mode Up to three-point automatic recognition calibration and one custom calibration, with five built-in standard calibration points 4.01, 6.86, 7.01, 9.18, 10.01 pH

  Oxidation-reduction

   ORP

     Measuring range

±2000.0mV

     Resolution 0.1 mV
     Accuracy ±1.0 mV
     Calibration mode Single-point custom calibration (relative mV)

  Dissolved oxygen

     Measuring range

0.0 to 500.0%; 0.00 to 50.00 ppm

     Resolution 0.1%; 0.01 ppm 
     Accuracy

0.0-300.0%: reading ±1.5% or ±1.0%, whichever is greater;

300.0-500.0%: reading ±3%; 0.00-30.00ppm: reading ±1.5% or ±0.10ppm, whichever is greater; 30.00-50

     Calibration mode Single-point or two-point automatic calibration, zero point or automatic 100% calibration in air

   Atmospheric pressure

     Measuring range

450.0 to 850.0 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 

1.1184atm; 60.00 to 113.32 kPa

     Resolution

0.1mm Hg;0.01 in Hg;0.1mbar;0.001 psi;0.0001 am;0.01kPa

     Accuracy ±3 mm Hg @±15℃
     Calibration mode Single-point user calibration

   Temperature

     Measuring range

-5.00 to 55.00℃; 23.00 to 131.00℉; 268.15 to

 328.15K

     Resolution 0.01℃;0.01℉;0.01K
     Accuracy ±0.15℃;±0.27℉;±0.15K
     Calibration mode Single-point user calibration

Other technical specifications

     Temperature compensation Automatic temperature compensation, -5.00 to 55.00℃, 23.00 to 131.00℉
     Data storage

45,000 measurement data storage, (continuous automatic storage or manual storage)

     Logging interval Settable from 1 second to 3 hours
     Data interface USB data interface (HI92000-15 data management software recommended)
     Operating environment

0 to 50℃(32 to 122 ℉); RH 100% IP67

     Battery power 1.5V AA battery*4, approximately 360 hours of continuous use
     Weight/Dimensions 185x93x35.2 mm (7.3x3.6x1.4'')/400 g (14.2 oz.)

The HI98196 is supplied with the HI7698196 probe, HI7698194-1 pH/ORP sensor, HI7698194-2 DO sensor, HI 76981942 probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), sensor O-rings (5), lubricant syringe, HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and a rugged carrying case with custom thermoformed insert.

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.