Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI98197

HI98197

Portable conductivity TDS meter

Portable EC-TDS-/resistivity-NaCl-temperature meter

Product Overview

Conductivity [EC]: 0.001 to 999.9 µS/cm, 1.000 to 1000.0 mS/cm; Total Dissolved Solids [TDS]: 0.00 to 999.9 mg/L (ppm) ppm, 1.000 to 400.0 g/L (ppt); Resistivity: 1.0 to 100.0 MOhms●cm

Practical salinity: 0.00 to 42.00 PSU, seawater salinity: 0.00 to 80.00 ppt(g/L), salinity: 0.0 to 400.0%NaCI; Temperature: -20.0 to 120.0°C, -4.0 to 248.0°F

  • High-precision EC-TDS-NaCI-°C/ºF/K meter, extra-large LCD display, fast and accurate measurement of routine water quality indicators such as conductivity EC-resistivity-total dissolved solids TDS-practical salinity (PSU)-seawater salinity-salinity (NaCI%)-temperature, automatic range recognition and unit conversion; new appearance design, on-screen calibration procedure prompts, GLP function, quick query of relevant data, USP (645) compliant with international pharmacopoeia measurement specifications, automatic recognition calibration and user-defined calibration, automatic endpoint locking function, USB data interface, large-capacity data storage, good data management.

  • New appearance design, large screen display, backlight, on-screen operation step prompts, multiple optional languages

  • Equipped with ECTDS electrode stainless steel flow-through cell, avoiding interference from carbon dioxide and other components in the air during measurement

  • 0.001μS/cm to 1000mS/cm, automatic resolution selection, automatic electrode recognition, automatic endpoint locking

  • USP <645> three-step conductivity analysis standard, compliant with international pharmacopoeia measurement specifications

  • Directly obtain GLP management data, including calibration points, calibration time and other information

  • Linear and non-linear temperature compensation (ISO/DIN 7888), 0.00 to 10.00%/C adjustable compensation coefficient

  • Three salinity measurement range options; practical salinity, seawater salinity (psu), salinity (%)

  • 400 sets of batch storage and 10000 sets of interval storage, USB data interface, storage interval from 5 seconds to 180 minutes, convenient data management

  • Novel design housing, designed for field measurement, excellent IP67 waterproof performance

Conductivity Measuring range 0.000 to 9.999 μS/cm *;10.00 to 99.99μS/cm;100.0to999.9μS/cm;1.000to9.999 mS/cm;
10.00 to 99.99 mS/cm;100.0 to 1000.0mS/cm (absolute EC; temperature compensated to 400mS/cm)
Resolution 0.001μS/cm;0.01μS/cm;0.1μS/cm;0.001mS/cm;0.01mS/cm;0.1mS/cm
Accuracy Reading ±1% (±0.01μS/cm or 1 digit), whichever is greater
Calibration mode Five-point automatic recognition calibration, selectable calibration points: 0, 84, 1413μS/cm, 5.00, 12.88, 80.0, 118.8mS/cm
Total Dissolved Solids TDS Measuring range 0.00 to 99.99mg/L (ppm), 100.0 to 999.9mg/L(ppm),1000 to 9.999g/L(ppt),
10.00 to 99.99g/L(ppt),100.0 to400.0g/L(ppt) (practical total dissolved solids)
Resolution 0.01, 0.1mg/L(ppm), 0.001, 0.01, 0.1g/L(ppt)
Accuracy Reading ±1% (±0.05mg/L or 1 digit), whichever is greater
Resistivity Measuring range 1.0 to t 99.9Ω·cm, 100 to 999Ω·cm, 1.00to9.99KΩ·cm, 10.0 to 99.9KΩ·cm, 100 to 999KΩ·cm
1.00 to 9.99MΩ·cm, 10.0to100.0MΩ·cm (practical resistivity)
Resolution 0.1, 1Ω.cm; 0.01, 0.1, 1KΩ.cm; 0.01, 0.1MΩ.cm
Accuracy Reading ±1% (±10.0Ω or 1 digit), whichever is greater
Salinity Measuring range Practical salinity: 0.00 to 42.00 PSU; seawater salinity: 0.00 to 80.00ppt (g/L); salinity: 0.0to400.0%NaCl
Resolution 0.1%;0.01
Accuracy Reading ±0.1%
Calibration mode Single-point calibration (% salinity calibration can use HI7037 salinity calibration solution), salinity calibration in other units requires no further calibration based on the conductivity calibration result
Temperature Measuring range  -20.0 to 120.0℃, -4.0 to 248.0°F
Resolution 0.1℃0.1℉
Accuracy ±0.2℃, ±0.4℉ (ignoring temperature probe error)
Calibration mode One-point or two-point calibration
Other technical specifications Conductivity constant 0.010 to 10.000
Temperature compensation Linear temperature compensation: -20.0to 120.0℃; -4.0 to 248.0℉
Non-linear temperature compensation 0 to 36℃; 32 to 98.6℉, ISO/DIS 7888 standard
Reference temperature 15℃, 20℃and 25℃
Temperature coefficient 0.00 to 10.00%/℃
TDS factor 0.40 to 1.00
Standard electrode HI763123 four-ring platinum EC/TDS electrode with built-in temperature sensor, DIN connector, 1m cable length
Data storage Manual storage: 400 data sets, interval storage up to 1000 data sets
Storage interval 5, 10,30sec, 1, 2,5,10,15,30,60,120,180min
Measurement curves Storage: up to 10
Measurement mode Automatic range selection, automatic endpoint locking
Power supply 4*1.5V AA batteries
Auto power off Set standby time: 5, 10, 30, 60 minutes and no auto power off mode
Operating environment 0 to 50℃(32 to 122 F); RH 100%IP67 waterproof standard
Dimensions/Weight 185*93*35.2mm/400g

Main unit, HI763123 four-ring platinum EC/TDS electrode with built-in temperature sensor, DIN connector, 1m cable length, 4*1.5V AA batteries, Chinese and English instruction manual

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.