HI98198

HI98198

Optical luminescent dissolved oxygen meter

Fluorescence dissolved oxygen DO - saturated dissolved oxygen meter

Product Overview

  • HI98198 uses the optical fluorescence (OPDO) measurement method to ensure the accuracy of dissolved oxygen measurement. With built-in standard methods and standards, it can easily measure dissolved oxygen DO, biochemical oxygen demand BOD, oxygen uptake rate OUR, and specific oxygen uptake rate SOUR without complex calculations.

  • Good usability

  • Powerful data management functions

  • Dedicated quick-connect dissolved oxygen electrode

Dissolved Oxygen DO

Range Dissolved oxygen DO: 0.00 to 50.00 mg/L (ppm), saturated dissolved oxygen: 0.0 to 500.0 %
Resolution Dissolved oxygen DO: 0.01  mg/L (ppm), saturated dissolved oxygen: 0.1 %
Accuracy

1.5% of reading ±0.01 mg/L (ppm) [0.00 to 20.00 mg/L]; 5% of reading [20.00 to 50.00 mg/L]; 1.5% of reading ±0.1% [0.0 to 200.0 %]; 5% of reading [200.0 to 500.0 %]

Calibration Single-point or two-point automatic calibration, automatic 100% calibration in zero point or air (8.26 mg/L); user-defined single-point calibration

Barometric Pressure

Range 420 to 850 mmHg
Resolution/Accuracy Resolution: 1 mmHg; Accuracy: ±3 mmHg within ±15% of calibration point
Calibration User-defined single-point manual calibration within the barometric pressure measurement range

Temperature

Range -5.0 to 50.0℃ (23 to 122 ℉), sensor type: thermistor
Resolution/Accuracy ±Resolution: 0.1℃ (0.1℉); Accuracy: ±0.3℃ (±0.4℉)
Calibration User-defined single-point manual calibration within the temperature range

Compensation Parameters

Temperature Compensation Automatic temperature compensation -5.0 to 50.0℃ (23 to 122.0℉)
Salinity Compensation Manual compensation range 0 to 70 PSU
Barometric Pressure Compensation Automatic compensation range 420 to

Data Management

Logging 4000 measurement data storage
Data Interface USB-C data interface, optional HI920016 dedicated USB A-C data cable to transfer stored data to a computer for convenient data management and analysis

Other Parameters

Standard Electrode HI764113 custom dedicated optical fluorescence dissolved oxygen electrode with built-in temperature sensor, specification: 4 m [equipped with HI764113-3 dissolved oxygen electrode 316 stainless steel protective sleeve, maximum withstand depth and pressure: 20 m/29 PSI]
Protection Standard Meter complies with IP67 waterproof international standard; HI764113 optical fluorescence dissolved oxygen electrode complies with IP68 waterproof international standard
Voltage Type 1.5V AAA x 4 high-quality batteries, auto power-off setting: 5, 10, 30, 60 minutes or disabled
Operating Environment 0 to 50 ℃ (32 to 122 ℉) max. RH 100%

HI764113 custom dedicated optical fluorescence dissolved oxygen electrode with built-in temperature sensor, specification: 4 m [equipped with HI764113-3 dissolved oxygen electrode 316 stainless steel protective sleeve, maximum withstand depth and pressure: 20 m/29 PSI]

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.