Overview
Download software here FREE The HI-9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters. The microprocessor based multi-sensor probe (buy separately) allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature. The probe transmits readings digitally with options to log data while disconnected from the meter.
An optional GPS provides location tracking of measurements. The complete system is simple to setup and easy to use. The HI-9829 is highly customisable and all necessary accessories, including the probe and sensors, carrying case, and solutions must be purchased separately.
Built in GPS Receiver Colour Coded, field replaceable sensors Waterproof protection Logging – from probe to meter Fast Tracker – Tag Identification system Sensor Check™ - Auto-recognition of all sensors GLP features – Meets good laboratory practices Connectivity – PC compatible via USB Help feature – On-screen user guides Backlight – Backlit, graphic LCD display Waterproof – waterproof casing Meter with or without GPS Built in GPS Receiver 12 channel GPS receiver and antenna Tracks location using satellites to within 30 feet Latitude and longitude recorded with readings Location naming for GPS coordinates Distance from current location to stored location HI-929829 software supplied integrates data collected with Google™ maps Measurement readings including GPS coordinates Date and time Named locations and remarks Sample number (Google™ maps is a registered trademark of Google™, HANNA Instruments Ltd; has no affiliation with Google™). Colour Coded, Field Replaceable Sensors - purchase separately Dissolved Oxygen HI-7609829-2 DO pH HI-7609829-0 pH HI-7609829-1 pH/ORP Conductivity and Turbidity HI-7609829-4 EC/Turbidity ISE HI-7609829-0 Ammonium ISE HI-7609829-11 Chloride ISE HI-7609829-12 Nitrate ISE Conductivity HI-7609829-3 EC Two probes to choose from (Basic or Logging) - purchase separately The HI-7609829 (basic) and HI-7629829 (logging) are multiparameter probes for use with the HI-9829 portable meter. It is an option to choose which probe will be supplied with the HI-9829.
By default the HI-9829 and corresponding probe will be supplied with a pH/ORP, conductivity and dissolved oxygen sensors. Either probe can be upgraded to measure turbidity with a turbidity/conductivity sensor. HI-7629829 Autonomously Logging Probe - customise and purchase separately Same as basic probe but with logging capability Logs data independent of HI-9829 meter Operates on 4 “AA” batteries for up to 70 days* Stores up to 140,000 single parameter readings or 35,000 for all parameters Logs data from 1 second to 3 hours Choose to be supplied with EC or EC/Turbidity sensor Supplied with USB cable for direct connection to Window’s compatible PC *All channels logging at 10 minute intervals with no averaging HI-7609829 Basic Probe - customise and purchase separately Digital probe that is less than 2 inches in diameter 3 colour-coded sensor inputs IP68 rating for continuous immersion in water Multistrand, multiconductor cable rated for 150 lbs (intermittent use) Available with 4, 10, or 20 meter cable Weighted shield protects all sensors Cable lengths The probes are available with a choice of cable lengths: 4m, 10m and 20m DIN connection Logging probes can be connected directly to a PC with the HI-76982910 USB adaptor cable and HI-929829 PC application software to download log files directly.
On screen features GPS Option The meter features an internal 12 channel GPS receiver and antenna that calculates its position to track locations along with measurement data. Quick Calibration The quick calibration feature allows for a single point calibration for pH, conductivity, and dissolved oxygen all in few simple steps. Graphing Capability Trend graphing with sample date and time may be viewed on the display or transferred to PC.
Features: Waterproof Protection – The meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probe features an IP68 rating for continuous immersion in water. Backlit Dot Matrix LCD Display – The HI-9829 features a backlit graphic LCD with on-screen help and the capability to display up to twelve parameters simultaneously.
The graphic display allows for the use of virtual keys to provide for an intuitive user interface. Intuitive Keypad – The fitted rubber keypad has dedicated keys for power, backlight, up/down arrows, help and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup, and logging of data.
The interface is intuitive for any user’s level of experience. Dedicated Help Key – Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration.
The help information displayed is relative to the setting/option being viewed. Auto-sensor Recognition - The probe and meter automatically recognise the sensors that are connected. Any ports not used on the probe will not have the parameter displayed or be configurable.
Automatic temperature compensation – Integrated temperature sensor allows for automatic temperature compensation of pH, conductivity, and dissolved oxygen measurements. Automatic Barometric Pressure Compensation – The meter features a built-in barometer with user-selectable units for dissolved oxygen pressure compensation. Quick Calibration – Quick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved oxygen.
Standard calibration options are available including pH up to three points, Conductivity at one point and dissolved oxygen up to two points. GLP Data – HI-9829 includes a GLP feature that allows users to view calibration data and calibration expiration information at the touch of a key. Calibration data includes date, time, buffers/standards used for calibration, and slope characteristics.
Data Logging – The HI-9829 allows users to store up to 44,000 continuous or log-on-demand samples with logging intervals from one second to three hours. Graphing Capability - Trend graphing with sample date and time stamp may be viewed on the display or transferred to a pc. PC Connectivity – Logged data can be transferred to a Windows compatible PC with the included HI-7698291 USB adapter and HI-929829 software.
Long Battery Life - The display of the meter has a battery icon indicator to show the remaining power. The meter is supplied with four 1.5V “C“ NiMH rechargeable batteries that provide up to 140 hours of battery life*. Rugged thermoformed carrying case – The HI-9829 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use.
The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components. * Without GPS or turbidity measurements Fast Tracker™—Tag Identification System HANNA’s Fact Tracker™—Tag Identification System simplifies test logging. iButtons with a unique ID can be installed at various sampling sites.
When the matching connector on the meter contacts the location button, measurements are logged and labelled with the alphanumeric user-entered location ID. Location, date, time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker™ system complements the GPS for ultimate tracking.
iButton. Tags are Easy to Install Install the optional TAGs near your sampling points for quick and easy iButton readings. Each TAG contains a computer chip with a unique identification code encased in stainless steel.
You can install a practically unlimited amount of TAGs. Additional TAGs can be ordered for all of your traceability requirements.
Specifications
| Parameter | Value |
|---|---|
| SKU | HI9829-02 |
| HI-9829 specification with/without GPS | No Probe |
| Temperature Compensation | Automatic from -5 to 55°C |
| Models with GPS | 12 Channel Receiver, 10m range |
| Logging memory from meter | 44,000 records |
| Logging interval | 1 second to 3 hours |
| Computer interface | USB (with HI-929829) |
| FastTracker™ TAG ID | Yes |
| Waterproof protection | IP67 |
| Environment | 0 to 50°C, RH 100% |
| Power supply | 1.5 V Alkaline C cells (4)/1.2V NiMH rechargeable C Cells (4) USB, 12V power adapter |
| Dimensions | 221 x 115 x 55mm |
| Weight | 750g |
| Maximum Probe Immersion | Depth – 20 metres |
| pH Range | 0.00 to 14.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| pH Calibration | automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer |
| mV Range | ±600.0 mV |
| mV Resolution | 0.1 mV |
| mV accuracy | ±0.5 mV |
| ORP Range | ±2000 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±1.0 mV |
| ORP Calibration | automatic at one custom point (relative mV) |
| EC Range | 0 to 200 mS/cm (absolute EC up to 400 mS/cm) |
| EC Resolution | Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm, Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm, Automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm |
| EC Accuracy | ±1% of reading or ±1 µS/cm whichever is greater |
| EC Calibration | automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
| TDS Range | 0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor) |
| TDS Resolution | Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L), Automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L), Automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L) |
| TDS Accuracy | ±1% of reading or ±1 ppm (mg/L), whichever is greater |
| TDS Calibration | based on conductivity or salinity calibration |
| Resistivity Range | 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm |
| Resistivity Resolution | dependent on resistivity reading |
| Resistivity Calibration | based on conductivity calibration |
| Salinity Range | 0.00 to 70.00 PSU |
| Salinity Resolution | 0.01 PSU |
| Salinity Accuracy | ±2% of reading or ±0.01 PSU whichever is greater |
| Salinity Calibration | based on conductivity calibration |
| Seawater σ Range | 0.0 to 50.0 σt, σ0, σ15 |
| Seawater σ Resolution | 0.1 σt, σ0, σ15 |
| Seawater σ Accuracy | ±1 σt, σ0, σ15 |
| Seawater σ Calibration | based on conductivity or salinity calibration |
| Ammonium-Nitrogen Range | 0.02 to 200.0 ppm Am (as NH4 +-N) |
| Ammonium-Nitrogen Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
| Ammonium-Nitrogen Accuracy | ±5 % reading or 2 ppm |
| Ammonium-Nitrogen Calibration | 1 or 2 point, 10 ppm and 100 ppm |
| Chloride Range | 0.6 to 200.0 ppm Cl (as Cl- ) |
| Chloride Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
| Chloride Accuracy | ±5 % of reading or 2 ppm |
| Chloride Calibration | 1 or 2 point, 10 ppm and 100 ppm |
| Nitrate-Nitrogen Range | 0.62 to 200.0 ppm Ni (as NO3 - -N) |
| Nitrate-Nitrogen Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200 ppm |
| Nitrate-Nitrogen Accuracy | ±5 % of reading or 2 ppm |
| Nitrate-Nitrogen Calibration | 1 or 2 point, 10 ppm and 100 ppm |
| Turbidity Range | 0.0 to 99.9 FNU; 100 to 1000 FNU |
| Turbidity Resolution | 0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU |
| Turbidity Accuracy | ±0.3 FNU or ±2 % of reading, whichever is greater |
| Turbidity Calibration | Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom |
| DO Range | 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) |
| DO Resolution | 0.1%; 0.01 ppm (mg/L) |
| DO Accuracy | 0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading |
| DO Calibration | automatic one or two points at 0 and 100% or one custom point |
| Atmospheric Pressure Range | 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
| Atmospheric Pressure Resolution | 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
| Atmospheric Pressure Accuracy | ±3 mm Hg within ±15°C from the temperature during calibration |
| Atmospheric Pressure Calibration | automatic at one custom point |
| HI-9829-10 | 25 sachets 10ppm ammonia-nitrogen calibration solution |
| HI-9829-10/11 | 10 sachets each of 10ppm and 100ppm ammonia-nitrogen calibration solution |
| HI-9829-11 | 25 sachets 100ppm ammonia-nitrogen calibration solution |
| HI-9829-12 | 25 sachets 10ppm chloride calibration solution |
| HI-9829-12/13 | 10 sachets each of 10ppm and 100ppm chloride calibration solution |
| HI-9829-13 | 25 sachets 100ppm chloride calibration solution |
| HI-9829-14 | 25 sachets 10ppm nitrate-nitrogen calibration solution |
| HI-9829-14/15 | 10 sachets each of 10ppm and 100pm nitrate-nitrogen calibration solution |
| HI-9829-15 | 25 sachets 100ppm nitrate-nitrogen calibration solution |
Manuals and documentation
Related Products
HANNA InstrumentsEPA Compliant Turbidity and Free & Total Chlorine Meter
HANNA InstrumentsHardness, High Range Test Kit
HANNA InstrumentsAlkaline battery size AAA
HANNA InstrumentsFilter holder with Luer lock
HANNA InstrumentsSyringe 10mL with Luer Lock
HANNA InstrumentsSample Preparation Kit for HI-833xx photometer series
Large pump head assembly
HANNA Instruments