Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI983313

HI983313
EC Mini Controllers
These compact, panel mounted, process controllers are for measuring electrolytic conductivity (EC) of a process stream, measuring in µS/cm.

Overview

These compact, panel mounted, process controllers are for measuring electrolytic conductivity (EC) of a process stream, measuring in µS/cm. Users may choose from automatic or manual dosing modes; when in automatic mode the dry contact relay is activated when a reading is above the set point. HI983313's relay can be used to activate a dosing pump or a solenoid that controls a valve, and HI983313 is ideal for source water or rinse water applications.

Specifications

ParameterValue
SKUHI983313
Temperature Compensationautomatic from 5 to 50°C (41 to 122°F) with β =2%/ºC
Calibrationmanual, with calibration trimmer
Outputgalvanic isolated 4-20 mA output; accuracy ±0.2 mA; 500 Ω maximum load (BL9833XX-2 only)
Setpointadjustable, covers measure range
Dosing Contactrelay maximum 2A (internal fuse protection), 250 VAC or 30 VDC
Dosing OvertimeDosing relay is disabled if setpoint is not reached within the set time interval. Timer adjustable between aprox. 5 to 30 minutes, or disabled by jumper.
External Disable InputNormally Open: enable / Closed: disable dosing (BL9833XX-2 only)
Power Supplymodels "-0": 12 VDC adapter (included); models "-1": 115/230 VAC; 50/60Hz; models "-2": 115/230 VAC, 4-20 mA Output. input: 10 VA for 115/230 VAC, 50/60 Hz models; 3 W for 12 VDC models; fuse protected; installation category II.
Dimensions83 x 53 x 99 mm (3.3 x 2.1 x 3.9'')
Weight12 VDC models, 200 g (7.1 oz); 115/230 VAC models 300 g (10.6 oz)