Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI983320-1

HI983320-1
Wall-Mount ORP Controller
HANNA Instruments HI983320-1
The HI983320-1 is a wall-mount ORP controller. Its rear panel carries the ORP BNC socket, reference and matching-pin terminals, dosing direction terminals for reducing or oxidising agent, a 4-20 mA ou…

Overview

The HI983320-1 is a wall-mount ORP controller. Its rear panel carries the ORP BNC socket, reference and matching-pin terminals, dosing direction terminals for reducing or oxidising agent, a 4-20 mA output and the power terminals. Dosing direction is set by a dry contact: open selects the reducing agent, closed selects the oxidising agent.

Specifications

ParameterValue
SKUHI983320-1
Electrode connectionBNC plug for ORP electrode
Reference connectionConnection for electrode reference
Matching pin connectionConnection for potential Matching Pin
Dosage selection terminalRdx/Oxd dosage selection terminal: contact open = reductant selection; contact closed = oxidant selection
Recorder output4-20 mA output terminal for recorder connection
Power supply terminalfor BL932700-0 model: 12 Vdc adapter; for BL932700-1 model: 115 Vac or 230 Vac option
Dosing drive contactThis contact acts as a switch for driving the dosing system (e.g. dosing pump)
External controlExternal control and disabling of dosing system
Overtime control jumperJumper for enabling (jumper in) or disabling (jumper removed) the overtime control
Overtime settingTrimmer for overtime setting (typically from 5 to 30 minutes)