Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI991003

HI991003

Portable wastewater pH-ORP meter

Waterproof portable pH-ORP-temperature meter

Product Overview

  • pH range: -2.00 to 16.00pH; pH-mV conversion: ±825 mV; ORP range: ±1999 mV Temperature: -5.0 to 105.0°C; 23.0 to 221.0°F

  • Designed for acidity-pH measurement of samples such as wastewater, municipal water, water treatment, and swimming pools

  • Extra-large LCD screen allows you to easily view pH, pH-mV, ORP, and temperature measurement readings and instrument performance status from multiple angles; features a dedicated Sensor Check™ function that allows users to check electrode status at any time; built-in amplifier and temperature sensor titanium-body pH/ORP electrode, new design, rugged and durable, compliant with IP67 waterproof standard (protection against dust and water immersion), portable two-button design, allowing you to quickly perform setup and calibration modes, making the meter easier to operate and providing measurement results for research and production

  • New exterior design, extra-large LCD screen, user-friendly design, ergonomic

  • The design of connecting the electrode at the bottom of the instrument makes the instrument more stable and very convenient to operate

  • Setup and calibration information prompts, automatic calibration, buffer recognition, automatic 1- and 2-point calibration 

  • Built-in 2 sets of calibration points pH4.01, 7.01, 10.01 and pH4.01, 6.86, 9.18 

  • Automatic endpoint lock, automatic or manual temperature compensation, simultaneous display of pH (ORP)/°C measurement

  • Two-button simple operation, 0.01pH resolution, high-precision measurement; good cost-performance ratio

  • Battery replacement is simple and quick, BEPS low-battery error-prevention system avoids erroneous measurements

  • Excellent waterproof performance, rapid laboratory analysis and on-site measurement

  • Recommended for electroplating baths, wastewater, swimming pools, and sewage treatment industries

Acidity pH Measuring range  -2.00 to 16.00pH
Resolution 0.01pH
Accuracy ±0.02pH
Calibration mode 1-2 point acidity automatic recognition calibration, built-in two sets of acidity standard calibration points (pH4.01, 7.01, 10.01 and pH4.01, 6.86, 9.18)
Temperature compensation Automatic temperature compensation, -5.0 to 105.0℃ (23.0 to 221.0℉)
pH-ORP conversion Measuring range ±825mV
Resolution 1mV
Accuracy ±1mV
Redox Measuring range ±1999mV
Resolution 1mV
ORP Accuracy ±0.2mV
Temperature Measuring range  -5.0 to 105.0℃ (23.0 to 221.0℉)
Resolution 0.1℃, 0.1℉
Accuracy ±0.5℃ (≤60℃.), ±1.0℃ (>60℃) ±1.0℉ (≤140℉), ±2.0℉ (>140℉) (excluding probe error)
Other Electrode type HI1296D stainless steel body with built-in temperature sensor composite acidity pH-redox ORP electrode
Power supply 3*1.5V AAA batteries, in measurement mode, automatically shuts off after 20 minutes of non-use
Operating environment 0 to 50℃ (32 to 122℉), RH max 100%
Dimensions and weight Meter dimensions: 152*58*30mm, meter weight: 205g

Meter, HI1296D (HI991001)/HI1297D (HI991002, HI991003) pH-ORP electrode with built-in temperature sensor and amplifier, Chinese and English instruction manual

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.