Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

JANUS SEKO SEKO Pneumatic Double Diaphragm Pump

JANUS SEKO SEKO Pneumatic Double Diaphragm Pump

SEKO pneumatic double diaphragm pump

SEKO JANUS
Configurable Models 20 models
JANUS series SEKO pneumatic double diaphragm pump Pump head material: PP, PVDF, aluminum, SS316L and POM Flow range: 7 L/min - 880 L/min Connection size: 1/4" -- 3 mm (fluid), 1/4" -- 6 mm (gas)

JANUS Series SEKO SEKO Pneumatic Double Diaphragm Pump

JANUS series pneumatic double diaphragm pumps provide a variety of pump head sizes, materials and seals for users to choose from. Whether it is highly corrosive acid, or high viscosity paint and adhesive, can be transported, the application is extremely wide.

reliability

  • 100% water-based media test before leaving the factory: dead head, starting and sealing

  • All plastic air system: durable and corrosion resistant under harsh conditions

  • Dry run, no damage to pump or system: no seal design

  • Maintenance: Easy and fast maintenance without any special tools

Security

  • Can provide conductive plastic pump (PVDF + carbon fiber pump head)

  • Special exhaust design: designed for low noise operation

  • Submerged installation: can be completely sunk into the medium to be transported according to fluid compatibility

  • Full bolt construction: provides the best sealing and safety

Features

  • Adjustable flow and pressure, simple adjustment method, no complex operation

  • Portable, compact, multi-occasion use, optional cart

  • Can transport fluids containing solid particles: ideal for transporting corrosive and high viscosity media

  • Special air system: no lubricating oil, no stall, no icing

  • A variety of pump head sizes and materials can be selected, suitable for conveying different fluids under various working conditions

  • High performance: high flow rate through optimized pump body design

  • Maximum self-suction height (dry suction) six meters: suitable for suction applications

  • Efficient valve structure design: low air consumption

  • Import and export connection can be customized, perfect to meet the installation requirements of different occasions

  • Safety "dead head" function to prevent damage to the pump due to outlet blockage

performance characteristics
Pump head material PP, PVDF, aluminum, SS316L, POM
Flow Range 7 l/min -880 l/min
maximum pressure 6-7-8(bar)
Connection Dimensions 1/4 -- 3"
maximum lift 6-70-80(m)
diaphragm NBR, EPDM, PTFE, HaiCi, Shandao rubber
valve ball NBR, EPDM, PTFE, SS316L
O-ring NBR, EPDM, PTFE, FPM

technical parameters:

Model flow Connection Size [BSP] maximum lift maximum pressure Maximum self-priming height Maximum delivery solid
body particle diameter
maximum viscosity Displacement per cycle Maximum cycle speed
L/min fluid gas m bar dry/Wet mm CPS cubic centimeter times/minute
JO007 ******* AB80 7 1/4" 4 60 6 2/7 2 5,000 15 470
JO018 ******* AB80 18 3/8" 6 70 7 3/9 2.5 10,000 35 520
JO030 ******* AB80 33 1/2" 6 70 7 3/9 3 15,000 60 550
JO060 ******* AB80 65 1/2" 1/4" 80 8 4/10 3.5 20,000 192 340
JO090 ******* AB80 100 3/4" 1/4" 80 8 4/10 4 15,000 400 250
JO120 ******* AB80 120 1" 1/4" 80 8 4/10 4 25,000 400 300
JO170 ******* AB80 190 1" 1/4" 80 8 4/10 7.5 35,000 964 197
JO250 ******* AB80 220 11/4" 1/4" 80 8 4/10 7.5 35,000 1,122 196
JO400 ******* AB80 300 DN40-11/2" 1/2" 80 8 4/10 8 40,000 2,278 133
JO700 ******* AB80 650 DN50-2" 3/4" 80 8 4.5/10 8.5 50,000 5,900 220
JO1K0 ******* AB80 880 DN80-3" 3/4" 80 8 5/10 10 55,000 7,000 125

Model Code:

Series
J JANUS Series Pneumatic Double Diaphragm Pump
Configuration
O standard
N external control type, without solenoid valve
Y external control type, with solenoid valve
Series flow Connection Size [BSP] maximum lift maximum pressure Maximum self-priming height Maximum delivery solid
body particle diameter
maximum viscosity Displacement per cycle Maximum cycle speed
L/min fluid gas m bar dry/Wet mm CPS cubic centimeter times/minute
007 7 1/4" 4 60 6 2/7 2 5,000 15 470
018 18 3/8" 6 70 7 3/9 2.5 10,000 35 520
030 33 1/2" 6 70 7 3/9 3 15,000 60 550
060 65 1/2" 1/4" 80 8 4/10 3.5 20,000 192 340
090 100 3/4" 1/4" 80 8 4/10 4 15,000 400 250
120 120 1" 1/4" 80 8 4/10 4 25,000 400 300
170 190 1" 1/4" 80 8 4/10 7.5 35,000 964 197
250 220 11/4" 1/4" 80 8 4/10 7.5 35,000 1,122 196
400 300 DN40-11/2" 1/2" 80 8 4/10 8 40,000 2,278 133
700 650 DN50-2" 3/4" 80 8 4.5/10 8.5 50,000 5,900 220
1K0 880 DN80-3" 3/4" 80 8 5/10 10 55,000 7,000 125
Connection Mode
1 BSP thread (metal ring)
2 flange (or BSP threaded flange)
4 Dual BSP Connection
5 NPT thread (metal ring)
6 flange (or NPT threaded flange)
7 Dual NPT connection
Pump head material
P PP carbon fiber
K PVDF carbon fiber
M POM
S SS316L
A Aluminum
gas diaphragm
H Haili
M Mountain Road Rubber
D EPDM
N NBR
Fluid Diaphragm
X without "T" diaphragm
T PTFE
valve ball
T PTFE
S SS316L
D EPDM
N NBR
tee
P PP
K PVDF
S SS316L
A Aluminum
M POM
Z PE-UHMW
O-ring
V FPM
D EPDM
N NBR
T PTFE
import and export
AB Standard (A-Absorption/B-Drainage)
market
0 the West
8 China
customization
0 standard
J O 007 1 P N T N P T AB 8 0
44 models · click to collapse
Municipal Wastewater Treatment

Municipal Wastewater Treatment · JANUS — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted JANUS properly configured on the existing plant, with the aim of air-operated double-diaphragm transfer with the JANUS range.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the JANUS configuration has to involve selected by flow, head, diaphragm material and air-valve type.

Configuration

Supply and installation were organised through the AODD series: AODD solution matched to air supply and pumped medium. On site this meant selected by flow, head, diaphragm material and air-valve type, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is fewer failures in harsh duty, noticeably reducing downtime, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · JANUS — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was air-operated double-diaphragm transfer with the JANUS range.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by flow, head, diaphragm material and air-valve type.

What We Did

We took a AODD series approach — AODD solution matched to air supply and pumped medium. Delivery was built around selected by flow, head, diaphragm material and air-valve type, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — fewer failures in harsh duty, noticeably reducing downtime, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · JANUS — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from JANUS, focusing on air-operated double-diaphragm transfer with the JANUS range.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The JANUS specification must therefore cover selected by flow, head, diaphragm material and air-valve type.

Delivery Approach

Delivery was handled as the AODD series — AODD solution matched to air supply and pumped medium. Execution centred on selected by flow, head, diaphragm material and air-valve type, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — fewer failures in harsh duty, noticeably reducing downtime, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · JANUS — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is JANUS; the focus is air-operated double-diaphragm transfer with the JANUS range.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by flow, head, diaphragm material and air-valve type.

Implementation

The scope ran through the AODD series: AODD solution matched to air supply and pumped medium. Technically it hinges on selected by flow, head, diaphragm material and air-valve type, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means fewer failures in harsh duty, noticeably reducing downtime, which cut the workload on the site maintenance team.