Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

SEKO Spring series piston dosing pump

SEKO Spring series piston dosing pump

SEKO Spring series piston dosing pump

SEKO SPRING-PS
Configurable Models 20 models
SEKO Spring series piston dosing pump, flow 1.5–304 l/h, max. pressure 4–20 bar. Liquid end in PVC / PVDF / SS316L with PTFE diaphragm, EPDM or FPM seals and ceramic or stainless steel valve balls — for continuous, accurate dosing in water treatment, chemical and food & beverage processes.

SEKO Spring series piston dosing pumps

The Spring series is SEKO's piston dosing pump range, covering continuous dosing from low flow at high pressure to high flow at low pressure. The reciprocating piston design with hard ceramic or stainless steel valve balls suits long, uninterrupted operation where dosing accuracy matters.

Key features

  • Flow range: 1.5–304 l/h
  • Maximum pressure: 4–20 bar
  • Wetted materials: PVC / PVDF / SS316L head, PTFE diaphragm, EPDM or FPM seals, ceramic or stainless steel valve balls
  • Variable-frequency and explosion-proof motors available, manually adjustable stroke length

Typical applications: dosing in water and wastewater treatment, chemical process metering, food & beverage additive dosing.

Model Name
PS1D011C21A4080 SEKO plunger dosing pump
PS2E064C SEKO plunger dosing pump
PS1D011C31A4080 SEKO plunger dosing pump
PS2E064A SEKO plunger dosing pump
PS1D038A21B4080 SEKO plunger dosing pump
PS1D017A34A4080 SEKO plunger dosing pump
PS2E076A SEKO plunger dosing pump
PS2E076C SEKO plunger dosing pump
PS1D064C31B4080 SEKO plunger dosing pump
PS1D054A21B4080 SEKO plunger dosing pump
PS1D006A34A4080 SEKO plunger dosing pump
PS1D011A31A4080 SEKO plunger dosing pump
PS1D038A24B4080 SEKO plunger dosing pump
PS1D038C24B4080 SEKO plunger dosing pump
PS1D006A24A4080 SEKO plunger dosing pump
PS1D006A31A4080 SEKO plunger dosing pump
PS2E038C SEKO plunger dosing pump
PS1D064C34B4080 SEKO plunger dosing pump
PS1D030C34B4080 SEKO plunger dosing pump
PS1D038C34B4080 SEKO plunger dosing pump
Municipal Wastewater Treatment

Municipal Wastewater Treatment · SPRING — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is SPRING; the focus is high-pressure plunger dosing with the SPRING range.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with selected by pressure class, flow range and seal type.

Implementation

The scope ran through the plunger pump series: plunger-pump solution for high-pressure, low-flow duty. Technically it hinges on selected by pressure class, flow range and seal type, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means well suited to high-pressure RO and boiler chemical dosing, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · SPRING — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on SPRING and the core task is high-pressure plunger dosing with the SPRING range.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So SPRING cannot be specified generically — it calls for selected by pressure class, flow range and seal type.

Solution

The Ainstru engineering team worked through the plunger pump series: plunger-pump solution for high-pressure, low-flow duty. The configuration involves selected by pressure class, flow range and seal type, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is well suited to high-pressure RO and boiler chemical dosing.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · SPRING — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted SPRING properly configured on the existing plant, with the aim of high-pressure plunger dosing with the SPRING range.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the SPRING configuration has to involve selected by pressure class, flow range and seal type.

Configuration

Supply and installation were organised through the plunger pump series: plunger-pump solution for high-pressure, low-flow duty. On site this meant selected by pressure class, flow range and seal type, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is well suited to high-pressure RO and boiler chemical dosing, and the readings are now used for process tuning.

Power & Energy

Power & Energy · SPRING — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was high-pressure plunger dosing with the SPRING range.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means selected by pressure class, flow range and seal type.

What We Did

We took a plunger pump series approach — plunger-pump solution for high-pressure, low-flow duty. Delivery was built around selected by pressure class, flow range and seal type, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — well suited to high-pressure RO and boiler chemical dosing, with routine maintenance falling noticeably.