Order Code:GEWADA-C.CD3
Name:G1½ threaded adapter for VEGAWAVE
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Version / Material | CD | Clamp 2½" PN10 (ø77.5mm) DIN32676, ISO2852 / 316L |
| 020 | Seal / Process temperature | 3 | EPDM / -40...+150°C FDA conformity |
Configuration Explained
This is the hygienic clamp connection for the S61 vibrating level switch, it measures granular bulk solids and works from a density of 100g/l, clamp 2.5 inch PN10, outer diameter 77.5mm, DIN32676 and ISO2852 standards, 316L stainless steel, EPDM seal, withstands -40 to 150°C, with FDA compliance, the clamp fits in one action so dismantling and cleaning are easy in hygienic applications, it is ready for service once installed on site, the original part dimensions match so nothing has to be modified when fitting.