Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

PS61.XXAGPIDMAX

PS61.XXAGPIDMAX
Product family: VEGAPULS 61
VEGAPULS 61
VEGA PS61.XXAGPIDMAX
VEGAPULS 61;Approval without;Version / Material / Process temperature with encapsulated horn antenna (ø40mm) / PVDF / -40...+80°C;Process fitting / Material Thread G1½ PN3, DIN3852-A / PVDF;Electronics Four-wire 4 ... 20 mA/HART; 9.6 ... 48 V DC; 20 ... 42 V AC;Housing / Protection Aluminium double chamber / IP66/IP68 (0.2bar);Cable entry / Cable gland / Plug connection M20x1.5 / with / without;Display/Adjustment module PLICSCOM mounted;Additional equipment without

Order Code:PS61.XXAGPIDMAX

Name:VEGAPULS 61

Configuration

CodeNameOrderSpecification
030ApprovalXXwithout
060Version / Material / Process temperatureAwith encapsulated horn antenna (ø40mm) / PVDF / -40...+80°C
070Process fitting / MaterialGPThread G1½ PN3, DIN3852-A / PVDF
080ElectronicsIFour-wire 4 ... 20 mA/HART; 9.6 ... 48 V DC; 20 ... 42 V AC
120Housing / ProtectionDAluminium double chamber / IP66/IP68 (0.2bar)
140Cable entry / Cable gland / Plug connectionMM20x1.5 / with / without
150Display/Adjustment module PLICSCOMAmounted
160Additional equipmentXwithout

Configuration Explained

This VEGAPULS 61 radar level transmitter has an encapsulated horn antenna of 40 mm, PVDF, process temperature -40 to 80°C, process connection G1½ thread, PN3, four-wire 4-20mA HART, supply 9.6 to 48V DC or 20 to 42V AC, aluminium dual chamber housing IP66/68, cable entry M20x1.5, with PLICSCOM display, non-hazardous area, it accepts both AC and DC, suitable for sites with mixed supply.

31 models · click to collapse