Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

VEGAPULS 62

VEGAPULS 62
VEGAPULS 62
VEGA PS62
Configurable Models 15 models
VEGAPULS 62 is a universal radar sensor for continuous level measurement of liquids. It is suitable for storage vessels, reactors and process vessels, and also for harsh process conditions. With different antenna types and materials, VEGAPULS62 is the optimal solution for virtually all applications and processes. The wide temperature and pressure range ensures
Compare

Measurement

Measuring range up to 35 m (114.8 ft)
Deviation ±2 mm

Process conditions

Process fitting Thread from G1½; 1½ NPT; flange from DN 40, 1½"
Process pressure -1 … +160 bar/-100 … +16000 kPa (-14.5 … +2320 psig)
Process temperature -196 … +450 ℃ (-321 … +842 ℉)
Ambient, storage and transport temperature -40 … +70 ℃ (-40 … +158 ℉)

Electrical & communication

Operating voltage ƲƲ Low voltage version 9.6 … 48 V DC, 20 … 42 V AC, 50/60 Hz ƲƲ Mains voltage version 90 … 253 V AC, 50/60 Hz

Certification

SIL certification Optional up to SIL2

Application area

The VEGAPULS 62 sensor can be used universally for continuous levelmeasurement in liquids.It is suitable for level measurement in storage containers, reactorsand process vessels, even under difficult process conditions. With itsvarious antenna versions and materials, VEGAPULS 62 is the optimalsolution for almost all applications and processes. Its wide temperatureand pressure range makes project planning simple.

Your benefit

  • Maintenance-free operation thanks to non-contact measuring princi­
  • ple
  • High plant availability, because wear and maintenance free
  • Exact measuring results independent of pressure, temperature, gas
  • and steam

Function

Extremely short microwave pulses are emitted by the antenna system inthe direction of the measured product, reflected by the product surfaceand received back again by the antenna system. The time from emis­sion to reception of the signals is proportional to the level in the vessel.A special time stretching procedure allows reliable and precise meas­urement of the extremely short signal running times.

15 models · click to collapse
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Flow Meter Accessories — Stock Configuration Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was completing flow meters with electrodes, liners, seals and mounting kits.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means matching electrode material, liner type and pressure rating against the original model.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around matching electrode material, liner type and pressure rating against the original model, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — restoring metering quickly instead of replacing whole instruments, with routine maintenance falling noticeably.

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Analyzer Accessories — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Analyzer Accessories properly configured on the existing plant, with the aim of supplying electrodes, flow cells, tubing and calibration consumables for analysers.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Analyzer Accessories configuration has to involve selected per measuring principle and range, never mixing principles.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected per measuring principle and range, never mixing principles, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is restoring original calibration intervals and data comparability, and the readings are now used for process tuning.

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Online Analyzer Accessories — Stock Configuration Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on Online Analyzer Accessories and the core task is completing online analysers with sampling, conditioning and flow-path parts.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So Online Analyzer Accessories cannot be specified generically — it calls for sizing conditioning stages to sample temperature, pressure and solids.

Solution

The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves sizing conditioning stages to sample temperature, pressure and solids, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is better sample representativeness and higher online availability.

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Ultrasonic level meter — Stock Configuration Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is Ultrasonic level meter; the focus is non-contact continuous level measurement in tanks and sumps.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with checking how vapour, foam and agitation affect the acoustic echo.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on checking how vapour, foam and agitation affect the acoustic echo, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means no fouling because nothing touches the medium, so maintenance stays low, which cut the workload on the site maintenance team.