Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

PS62.CXCAJ2FAMAX

PS62.CXCAJ2FAMAX
Product family: VEGAPULS 62
VEGAPULS 62
VEGA PS62.CXCAJ2FAMAX
VEGAPULS 62;Approval ATEX II 1G, 1/2G, 2G Ex ia IIC T6;Version / Material with horn antenna (ø48mm) / 316L;Process fitting / Material Flange NPS 3" Class 300 RF, ASME B16.5 / 316/316L;Seal / Process temperature FKM (SHS FPM 70C3 GLT) and PTFE / -40...+130°C;Electronics Two-wire Foundation Fieldbus;Housing / Protection Aluminium single chamber / IP66/IP68 (0.2bar);Cable entry / Cable gland / Plug connection M20x1.5 / with / without;Display/Adjustment module PLICSCOM mounted;Ad

Order Code:PS62.CXCAJ2FAMAX

Name:VEGAPULS 62

Configuration

CodeNameOrderSpecification
030ApprovalCXATEX II 1G, 1/2G, 2G Ex ia IIC T6
060Version / MaterialCwith horn antenna (ø48mm) / 316L
080Process fitting / MaterialAJFlange NPS 3" Class 300 RF, ASME B16.5 / 316/316L
090Seal / Process temperature2FKM (SHS FPM 70C3 GLT) and PTFE / -40...+130°C
100ElectronicsFTwo-wire Foundation Fieldbus
140Housing / ProtectionAAluminium single chamber / IP66/IP68 (0.2bar)
160Cable entry / Cable gland / Plug connectionMM20x1.5 / with / without
170Display/Adjustment module PLICSCOMAmounted
190Additional equipmentXwithout

Configuration Explained

This VEGAPULS 62 radar level transmitter has a 48 mm horn antenna, 316L, process temperature -40 to 130°C, process connection NPS 3 inch Class300 RF flange, output over Foundation Fieldbus, aluminium single chamber housing IP66/68, with PLICSCOM display, ATEX intrinsically safe approval, suitable for level measurement in explosion-proof tank farms that already have an FF bus and require a high pressure rating.