Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

VEGAPULS 64

VEGAPULS 64

VEGAPULS 64

VEGA PS64
Configurable Models 20 models
应用范围 小尺寸过程连接在小型储罐及狭小空间中尤其具有优势。仪表信号聚焦能力强,可用于含有各种内构件的容器。 VEGAPULS 64 雷达液位计适用于液体的连续液位测量,小尺寸过程连接在小型储罐及狭小空间中尤其具有优势。仪表信号聚焦能力强,可用于含有搅拌装置、加热盘管等各种内构件的容器。 您的获益 测量精准,不受工况条件影响 无磨损,无需维护,提高设备利用率 采用非接触式测量,运行免维护

应用范围

小尺寸过程连接在小型储罐及狭小空间中尤其具有优势。仪表信号聚焦能力强,可用于含有各种内构件的容器。

VEGAPULS 64 雷达液位计适用于液体的连续液位测量,小尺寸过程连接在小型储罐及狭小空间中尤其具有优势。仪表信号聚焦能力强,可用于含有搅拌装置、加热盘管等各种内构件的容器。

您的获益

  • 测量精准,不受工况条件影响
  • 无磨损,无需维护,提高设备利用率
  • 采用非接触式测量,运行免维护
39 models · click to expand
Model Name
PS64.AXBXXCHXAMAXX VEGAPULS 64
PS64.AXHRAIHXKMXXX VEGAPULS 64
PS64.AXFFBIHXAMAXX VEGAPULS 64
PS64.AXFFLIHXKMKXX VEGAPULS 64
PS64.AXGFBIHXAMAXX VEGAPULS 64
PS64.AXFIHIHXKMXXX VEGAPULS 64
PS64.GXFFHKHXATKXX VEGAPULS 64
PS64.IXBXDCHXKMAXX VEGAPULS 64
PS64.ACFF4JHXAMXXM VEGAPULS 64
PS64.ICTTDAHXADKXX VEGAPULS 64
PS64.IXTTCAHXAMAXX VEGAPULS 64
PS64.AXBAADHXAMKXX VEGAPULS 64
PS64.AEUTAAHXDNAXX VEGAPULS 64
PS64.ACTTAAHXADXXX VEGAPULS 64
PS64.AXTTCAHXKMXXX VEGAPULS 64
PS64.GXFF2KHX8MXXX VEGAPULS 64
PS64.AXFFHIHXKMXXX VEGAPULS 64
PS64.AOFFJIHXVMAXX VEGAPULS 64
PS64.AXBXXCHXKMAXX VEGAPULS 64
PS64.GXFF4KHX8MXXX VEGAPULS 64
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Flow Meter Accessories — Stock Configuration Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was completing flow meters with electrodes, liners, seals and mounting kits.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means matching electrode material, liner type and pressure rating against the original model.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around matching electrode material, liner type and pressure rating against the original model, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — restoring metering quickly instead of replacing whole instruments, with routine maintenance falling noticeably.

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Analyzer Accessories — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Analyzer Accessories properly configured on the existing plant, with the aim of supplying electrodes, flow cells, tubing and calibration consumables for analysers.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Analyzer Accessories configuration has to involve selected per measuring principle and range, never mixing principles.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected per measuring principle and range, never mixing principles, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is restoring original calibration intervals and data comparability, and the readings are now used for process tuning.

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Online Analyzer Accessories — Stock Configuration Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on Online Analyzer Accessories and the core task is completing online analysers with sampling, conditioning and flow-path parts.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So Online Analyzer Accessories cannot be specified generically — it calls for sizing conditioning stages to sample temperature, pressure and solids.

Solution

The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves sizing conditioning stages to sample temperature, pressure and solids, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is better sample representativeness and higher online availability.

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Ultrasonic level meter — Stock Configuration Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is Ultrasonic level meter; the focus is non-contact continuous level measurement in tanks and sumps.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with checking how vapour, foam and agitation affect the acoustic echo.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on checking how vapour, foam and agitation affect the acoustic echo, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means no fouling because nothing touches the medium, so maintenance stays low, which cut the workload on the site maintenance team.