Order Code:PS64.AXFFLIHXKMKXX
Name:PS64.AXFFLIHXKMKXX
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 020 | Scope | A | Europe |
| 030 | Approval | X | for Ex-free area |
| 040 | Antenna version / Second Line of Defense | F | Flange with encapsulated antenna system / without |
| 050 | Process fitting / Material | FL | Flange DN100 PN16 Form C, DIN2501 / 316/316L |
| 060 | Material / Seal / Process temperature | I | PTFE / PTFE / -40...+130 °C |
| 070 | Electronics | H | Two-wire 4 ... 20 mA/HART |
| 080 | Supplementary electronics | X | without |
| 110 | Housing / Protection | K | Plastic single chamber / IP66/IP67 |
| 130 | Cable entry / Connection | M | M20x1.5 / Cable gland PA black (ø5-9mm), standard |
| 140 | Display/Adjustment module PLICSCOM | K | mounted; with Bluetooth, magnetic pen operation |
| 150 | Additional equipment | X | without |
| 160 | Certificates | X | No |
Configuration Explained
This is a VEGAPULS 64 radar level transmitter, flange with encapsulated antenna system, PTFE, process temperature -40 to 130°C, process connection DN100 PN16 Form C flange, 316/316L, two-wire 4-20mA HART, plastic single chamber housing IP66/67, display module with Bluetooth, operable with a magnetic pen, parameters can be adjusted without switching off power, non-hazardous area, suitable for level measurement in small tanks and vessels with limited space.