Order Code:PS69.IJCSEBHXWNAXM
Name:PS69.IJCSEBHXWNAXM
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 020 | Scope | I | Worldwide |
| 030 | Approval | J | ATEX II 1/2G, 2G Ex db IIC T6 + II 1D, 1/2D, 1/3D, 2D Ex ta IIIC T* |
| 040 | Version / Material | C | Metal jacketed lens antenna with rinsing air connection / PEEK |
| 050 | Process fitting / Material | SE | Swivelling holder with flange 6" 150lb / 316/316L |
| 060 | Seal / Process temperature | B | FKM (SHS FPM 70C3 GLT) and PEEK / -40...+200°C |
| 070 | Electronics | H | Two-wire 4 ... 20 mA/HART |
| 080 | Supplementary electronics | X | without |
| 110 | Housing / Protection | W | Stainless steel double chamber / IP66/IP68 (0.2 bar) |
| 130 | Cable entry / Connection | N | ½NPT / Blind plug |
| 140 | Display/Adjustment module PLICSCOM | A | mounted |
| 150 | Additional equipment | X | without |
| 160 | Certificates | M | Yes |