Order Code:PT31.DK1BDMBX006
Name:POINTRAC 31
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 020 | Approval | DK | GOST-R 1Ex d [ia Ga]IIC T1...T6 Gb, Ex ta [ia] IIIC T1...T6 Da IP66, Ex tb [ia Da] IIIC T1...T6 Db IP66 |
| 030 | Version / Ambient temperature | 1 | Standard / -40...+60ºC |
| 040 | Electronics | B | Four-wire 8/16 mA/HART (Ex-ia output) |
| 050 | Housing / Protection | D | Aluminium double chamber / IP66/IP67 |
| 070 | Cable entry / Cable gland / Plug connection | M | M20x1.5 / with / without |
| 080 | Display/Adjustment module PLICSCOM | B | mounted |
| 090 | Additional equipment | X | without |
| 110 | Length | 006 | 6" / 152mm |
Configuration Explained
This POINTRAC 31 is a radiometric point level switch, point level, the source and detector are mounted outside the tank so they do not touch the medium and no large opening is needed, GOST-R approval, 1Ex d [ia Ga] IIC T1 to T6 Gb, dust Da, Db protection IP66, ambient temperature -40 to +60 °C, four-wire 8/16mA HART, Ex-ia intrinsically safe output, aluminium dual chamber housing IP66/IP67, cable entry M20x1.5 with cable gland, length 152mm, used for tank full alarms and empty tank protection.