VEGA SWING63.CAACVXMN
Tuning fork level switch;Approval II 1G, 1/2G, 2G Ex ia IIC T6...T1 Ga, Ga/Gb, Gb + Overfill protection (WHG, KVU, VLAREM);Process fitting / Material Flange NPS 2" Class 150 RF, ASME B16.5 / 316/316L;Adapter / Process temperature without / -50...+150°C;Housing / Protection / Cable gland Aluminium single chamber IP66/IP67 / M20x1.5;Electronics NAMUR signal

Order Code:SWING63.CAACVXMN

Name:Tuning fork level switch

Configuration

CodeNameOrderSpecification
030ApprovalCAII 1G, 1/2G, 2G Ex ia IIC T6...T1 Ga, Ga/Gb, Gb + Overfill protection (WHG, KVU, VLAREM)
040Process fitting / MaterialACVFlange NPS 2" Class 150 RF, ASME B16.5 / 316/316L
050Adapter / Process temperatureXwithout / -50...+150°C
060Housing / Protection / Cable glandMAluminium single chamber IP66/IP67 / M20x1.5
090ElectronicsNNAMUR signal

Configuration Explained

This is a SWING63 vibrating level switch, with ATEX intrinsic safety approval and WHG overflow protection, usable in hazardous areas, NPS 2 inch Class150 RF flange process connection, according to ASME B16.5, 316/316L, resistant to -50 to 150 °C, aluminium single-chamber housing IP66/67, M20 entry, NAMUR signal electronics with isolation barrier, suitable for overflow prevention of US standard hazardous area tanks.