Application

The switching point can be located up to 80 m away from the installation point. The surface of the vibrating rod is smooth, with no edges or corners, preventing solids from clogging or jamming and facilitating cleaning.

VEGAVIB 62 is used for point level measurement of granular and coarse bulk solids. The optimized rod surface has no corners, preventing bulk solids from accumulating or jamming and is extremely easy to clean. VEGAVIB 62 guarantees safe and precise minimum and maximum point level measurement of bulk solids. The switching point position is flexibly determined by the length of the load cable.

Your benefit

  • Low maintenance and servicing costs
  • Simple commissioning without medium, saving time and costs
  • Reliable and safe function, switching point independent of the product

Technical data

4 models · click to expand
Model Name
VB62.XXEGCRAMX Vibrating level switch
VB62.XXTGCRAMX Vibrating level switch
VB62.XXTGDRKMX VEGAVIB 62
VB62.GXTGDTAMX Vibrating level switch
Municipal Wastewater Treatment

Municipal Wastewater Treatment · tuning fork — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was vibrating-fork point level detection and high/low alarms.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing fork length and surface finish by density and stickiness.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing fork length and surface finish by density and stickiness, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — no calibration needed, with dependable switching, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · tuning fork — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from tuning fork, focusing on vibrating-fork point level detection and high/low alarms.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The tuning fork specification must therefore cover choosing fork length and surface finish by density and stickiness.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing fork length and surface finish by density and stickiness, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — no calibration needed, with dependable switching, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · tuning fork — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is tuning fork; the focus is vibrating-fork point level detection and high/low alarms.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing fork length and surface finish by density and stickiness.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing fork length and surface finish by density and stickiness, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means no calibration needed, with dependable switching, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · tuning fork — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on tuning fork and the core task is vibrating-fork point level detection and high/low alarms.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So tuning fork cannot be specified generically — it calls for choosing fork length and surface finish by density and stickiness.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing fork length and surface finish by density and stickiness, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is no calibration needed, with dependable switching.