Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

201680 TriOxmatic® 701-15

201680 TriOxmatic® 701-15

TriOxmatic® 701-15

WTW 201680
D.O. sensor with SensCheck for higher accuracy at low D.O. concentrations (e.g. denitrification), for use with analog monitors. Supplied with accessory kit (ZBK 25i), consisting of: 2 membrane heads (WP 25i/2), 50 mL electrolyte solution (ELY/A), 50 mL cleaning solution, 1 cathode cleaner (SF300), with integrated temperature sensor (NTC), 15 m/49 ft cable and waterproof plug

Product Overview

  • Electro-chemical sensor to measure dissolved oxygen

  • The TriOxmatic® with 3 electrode system for the reliable oxygen measurement - patented know-how at low investment costs:

  • Reliable operation by proven technology

  • No run in, no drift: Stable measured values from the beginning to the end

  • Self diagnosis system SensReg/SensLeck by 3 electrode system

  • In the analog sensors of the TriOxmatic® series, you will find the ideal solution for your application. In addition to the continuous measuring accuracy, the sensors are equipped with an automatic self diagnosis system, a shorter response time and different cable lengths as options. Regardless of this, all models are supplied with accessories kits and can be connected to the monitor Oxi 298 (exception: TriOxmatic® 700).

  • TriOxmatic® 700 – predestined for the use in biological cleaning steps (wastewater treatment plants)

  • Universal oxygen sensor with high measuring accuracy and automatic self diagnosis SensReg (electrolyte consumption) and SensLeck (membrane monitoring). Based on its median response time of t90 < 180 s, the sensor is insensitive to air bubbles and therefore predestined for measurement and regulation of the oxygen content in biological cleaning steps of wastewater treatment plants. The TriOxmatic® 700 is alwo available as a salt water version.

  • Nur noch als Nachrüstarmatur für analoge Umformer der Serien Ecoline® und QuadroLine®. Als digitale Version weiterhin erhältlich (IQ SENSOR NET System 181).

  • TriOxmatic® 690 – suitable for pure measuring tasks in wastewater/water

  • Very economic model without self diagnosis. This makes this oxygen sensor suitable especially for pure measuring tasks in wastewater/water where a continuous membrane and electrolyte monitoring is not necessary.

  • TriOxmatic® 701 – increased resolution for the residual oxygen in the denitrification

  • Based on the increased resolution, a shorter response time (t90 < 30 s) and the thinner special membrane, this sensor can be used for quicker response processes with lower O2 concentrations (e.g. for the measurement of residual oxygen and the denitrification).

Model

TriOxmatic® 690

TriOxmatic® 701

Order No.

201690, 201692, 201693V

201678, 201680, 201682V

Measuring principle

Electrochemical

Measuring Range (25 °C, depends on respective controller)

 

O2 Concentration

0.0 ... 60.0 mg/l

0.00 ... 20.00 mg/l; 0.0 ... 60.0 mg/l

O2 Saturation

0 ... 600 %

0.0 ... 200.0 %; 0 ... 600 %

Resolution

O2 Concentration

0.1 mg/l

0.01 mg/l; 0.1 mg/l

O2 Saturation

1 %

0.1 %; 1 %

Response time at 25 °C

t90: 180 s

t90: 30 s; t99: 90 s

Minimum flow rate

0.05 m/s

0.23 m/s

SensCheck

–

SensLeck, SensReg

Temperature Measurement

Integrated NTC, -5 °C ... +50 °C

Temperature Compensation

0 °C ... +50 °C

Pressure Resistance

Maximum 10 bar

Ambient Conditions

Operational temperature: 0 °C ... +50 °C; Storage Temperature: -5 °C ... +50 °C

Electrical Connection

Integrated connection cable with 7-pole screw plug (IP 65); electrical supply via WTW controller

Electromagnetic Compatibility

According to EN 61326 class B and FCC class A

Certifications

CE, cUL, UL

Mechanical

Membrane/
sensor head, Protection hood

POM

Housing shaft

Stainless steel 1.4571

Protection Rating

IP 68

Cable

PUR

PU

Weight (without cable)

Approx. 660 g

Warranty

2 years on defects in quality according to § 10 terms of conditions

Municipal Wastewater Treatment

Municipal Wastewater Treatment · WTW — Stock Configuration Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is WTW; the focus is covering online and laboratory water analysis with WTW instruments.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, range and digital sensor protocol.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, range and digital sensor protocol, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means plug-and-play digital sensors that keep calibration when swapped, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · WTW — Stock Configuration Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on WTW and the core task is covering online and laboratory water analysis with WTW instruments.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So WTW cannot be specified generically — it calls for selected by parameter set, range and digital sensor protocol.

Solution

The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves selected by parameter set, range and digital sensor protocol, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is plug-and-play digital sensors that keep calibration when swapped.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · WTW — Stock Configuration Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted WTW properly configured on the existing plant, with the aim of covering online and laboratory water analysis with WTW instruments.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the WTW configuration has to involve selected by parameter set, range and digital sensor protocol.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, range and digital sensor protocol, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is plug-and-play digital sensors that keep calibration when swapped, and the readings are now used for process tuning.

Power & Energy

Power & Energy · WTW — Stock Configuration Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was covering online and laboratory water analysis with WTW instruments.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means selected by parameter set, range and digital sensor protocol.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, range and digital sensor protocol, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — plug-and-play digital sensors that keep calibration when swapped, with routine maintenance falling noticeably.