Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

600011 VisoTurb® 700 IQ SW

600011 VisoTurb® 700 IQ SW

VisoTurb® 700 IQ SW

WTW 600011
Digital turbidity sensor for industrial and seawater applications (ultrasonic cleaning) for use with the IQ SENSOR NET system. Please order connection cable separately.

Turbidity sensor with ultrasonic cleaning, connectable to the IQ SENSOR NET

VisoTurb®: Optical turbidity sensors according to nephelometric principle according to EN ISO 7027 for the in-situ use in water/wastewater with ultrasonic cleaning system:

  • Ultrasonic cleaning without mechanics
  • Extremely low-maintenance
  • Highly accurate factory calibration
  • High operational safety (sensor check function)

The ultrasonic cleaning system ensures the low-maintenance and continuously reliable measuring operation of the sensors, which are therefore very suited for extreme applications, such as wastewater treatment plants.

With the nephelometric measuring principle of the VisoTurb®, the stray light is measured at a 90° angle. The measuring setup is suitable for low and medium turbidity values up to 4000 FNU. According to EN ISO 7027, infrared light is used in the wavelength range of 860 nm. This wave length is outside the visible range, so that possible sample colorings generally do not cause any interference.

The sea water model includes the sensor for use in special media: All wetted parts are made of titanium and plastic and are therefore extremely resistant to corrosion.

Model

VisoTurb® 700 IQ

VisoTurb® 700 IQ SW*

Order No.

600010

600011

* SW: Sensor as sea water model (with plastic arming (POM))

Measuring method

Nephelometric principle in compliance with EN ISO 7027

Measuring range

FNU; NTU; TEF

0.05 ... 4000 FNU

mg/l SiO2; ppm SiO2

0.1 ... 4000 mg/l SiO2

g/l TS

0.0001 ... 400 g/l TS

Resolution

FNU; NTU; TEF

Automatic according to measuring range 0.001 ... 1 FNU

mg/l SiO2; ppm SiO2

0.001 mg/l ... 0.01 g/l

g/l TS

0.001 mg/l … 1 g/l

Accuracy

Process variation coefficient according to DIN 38402 part 51 <1 % (in the range up to 2000 FNU)
Repeatability according to DIN ISO 5725 or DIN 1319 < 0.015 % or ≥ 0.006 FNU

Calibration

FNU; NTU; TEF

Factory calibration with formazine

mg/l SiO2; ppm SiO2

Factory calibration with SiO2

g/l TS

Calibration by user, (TSS regulations in compliance with DIN 38414)

Cleaning System

Ultrasound cleaning system

SensCheck

Contamination detection of optical window; failure of cleaning system

Pressure Resistance

10 bar (incl. sensor connection cable)

Maximum 2 bar

Ambient Conditions

Operating temperature: 32 ... 140 °F (0 ... 60 °C);
ultrasonic cleaning system: 32 ... 104 °F (0 ... 40 °C) (overheating protection);
Storage temperature: 23 ... 149 °F (-5 ... +65 °C)

Electrical connections

2-wire shield cable with quick fastener to sensor

Electromagnetic Compatibility

EN 61326, Class B, FCC Class A;
Intended for indispensable operation

Certifications

CE

CE

Mechanical

Measuring window: Sapphire;
Sensor body: V4A stainless steel 1.4571;
Protection rating: IP 68

Measuring window: Sapphire;
Sensor body: Titanium, POM;
Protection rating: IP 68

Weight (without cable)

Approx. 2.18 lb (900 g)

3.13 lb (1420 g)

Warranty

2 years for defects in quality

Municipal Wastewater Treatment

Municipal Wastewater Treatment · WTW — Stock Configuration Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is WTW; the focus is covering online and laboratory water analysis with WTW instruments.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, range and digital sensor protocol.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, range and digital sensor protocol, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means plug-and-play digital sensors that keep calibration when swapped, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · WTW — Stock Configuration Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on WTW and the core task is covering online and laboratory water analysis with WTW instruments.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So WTW cannot be specified generically — it calls for selected by parameter set, range and digital sensor protocol.

Solution

The Ainstru engineering team worked through the stock channel: configuring from stock and delivered quickly. The configuration involves selected by parameter set, range and digital sensor protocol, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is plug-and-play digital sensors that keep calibration when swapped.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · WTW — Stock Configuration Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted WTW properly configured on the existing plant, with the aim of covering online and laboratory water analysis with WTW instruments.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the WTW configuration has to involve selected by parameter set, range and digital sensor protocol.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, range and digital sensor protocol, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is plug-and-play digital sensors that keep calibration when swapped, and the readings are now used for process tuning.

Power & Energy

Power & Energy · WTW — Stock Configuration Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was covering online and laboratory water analysis with WTW instruments.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means selected by parameter set, range and digital sensor protocol.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, range and digital sensor protocol, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — plug-and-play digital sensors that keep calibration when swapped, with routine maintenance falling noticeably.