COD-60A Permanganate Index Analyzer
Application industries:
The COD-60A permanganate index analyzer can be used for the determination of oxygen demand / permanganate index in drinking water, surface water, groundwater, seawater, industrial water, and other fields.
Instrument features:
1) The COD-60A permanganate index analyzer uses the accurate coulometric titration method. It responds sensitively and provides accurate data.
2) The digestion time of this permanganate index analyzer is adjustable within a range of approximately 10 to 800 seconds. The permanganate index measurement data can be obtained in about 5 to 10 minutes, making it convenient and quick.
3) Multiple ranges, direct reading of COD values: The range is set according to the dilution ratio, allowing direct reading of the COD value of the undiluted original solution without conversion.
4) Simple operation: The measurement unit is integrated, combining oxidation and titration processing steps. After setting the instrument, one-touch operation automatically completes the entire process from zero calibration, oxidation, and titration to data printing.
5) Convertible to standard method measured values: Calibration and coefficient adjustment can be performed using the standard method. By determining in advance the correlation between the laboratory standard analytical method and the COD-60A permanganate index analyzer, and inputting the linear regression equation, converted values for the standard analytical method can be obtained.
6) Automatic standard program control reduces operating errors: This permanganate index analyzer uses a proprietary system control to automatically perform steps such as oxidation state (heating/cooling) and titration. It automatically controls temperature and, based on coulometric titration, performs titration using self-cleaning electrodes. This reduces human errors between operators.
7) Various maintenance/inspection functions: The COD-60A permanganate index analyzer uses an electrode cleaning mode and a self-check titration mode, making maintenance and inspection work easy.
8) Data storage function (100 sets), built-in printer, and clock: The permanganate index measurement results can be printed after measurement is completed, and historical data can be displayed or printed later.
Measurement method: Acidic (or alkaline) potassium permanganate method
Measurement principle: Coulometric titration (endpoint detection by redox potential method)
Digestion time: Adjustable from 10 to 800 s
Titration temperature: 65℃
Display: Graphic LCD display
During measurement: real-time display of sequence status, sample solution temperature, titration curve, etc.
Error messages: titration failure, blank error, out of effective range
Measurement range: Standard: 0~20/40/100/200/400/1000mg/L
Arbitrary: 0~(10~2000mg/L settable)
Dilution required for 0~20mg/L and above
Repeatability: ±2%FS
Resolution: 0.01mg/L
Program control: Fully automatic measurement processing from oxidation to titration (acidic method only)
Calculation functions: Regression formula conversion function
Statistical calculation (average value)
Automatic input of blank value (or manual input)
Data storage: 100 data records (measurement time, sample number, result)
Printer: Built-in
Output: RS-232C, external printer
Power supply: AC220V50/60Hz
Weight: Main unit: approx. 3.5kg
Related reagents
| Order No. | Description | Parameters | Analysis method | Packaging | Range | Guaranteed shelf life (days) |
|---|---|---|---|---|---|---|
| 2125925-CN | Chemical oxygen demand (COD) digestion reagent, high range, HW, pk/25 | COD (chemical oxygen demand) | 8000 DR800 low range, medium range, high range | 25/pk | 0-150mg/L, COD | 150 |
| 2125825-CN | rr Chemical oxygen demand (COD) digestion reagent, low range, HW, pk/25 | Chemical oxygen demand | Chemical oxygen demand (COD) 8000 3-150mg/L Chemical oxygen demand (COD) 8000 0-150mg/L Chemical oxygen demand (COD) 8000 3-150mg/L low range Chemical oxygen demand (COD) 8000 20-1500mg/L Chemical oxygen demand (COD) 8000 20-1,500mg/L |
25/pk | 3-150mg/L, COD | 150 |
| 2415925-CN | rr Chemical oxygen demand (COD) digestion reagent, high range+, pk/25 | - | Chemical oxygen demand (COD) 8000 200-15,000mg/L Chemical oxygen demand (COD) 8000 0-15,000mg/L |
- | 200-15,000mg/L | 150 |
| TNT820-CN | rr Chemical oxygen demand (COD), TNT+, ultra-low range (1.0-60mg/L), pk/24 | COD (chemical oxygen demand) | 10211 TNTplus ultra-low range | - | 1.0-60.0mg/L | 150 |
| 2415825-CN | rr Chemical oxygen demand (COD) digestion reagent, ultra-low range, pk/25 | COD (chemical oxygen demand) | 8000 digestion colorimetric | - | 0.7-40.0mg/L | 150 |
Ordering guide
Complete unit Order No.: COD60A-2-6
Standard accessories
Name Order No. Quantity
Measuring vessel, support rod, and positioner 0KK00001 1
Electrode sheath 0IB00011 1
Measurement electrode 1 0LA00001 1
Measurement electrode 2 0LA00002 1
Measuring cell 0DA00002 2
Measuring cell holder 0LZ00003 1
Stirring bar 0SE00001 1
Reagent 1 (100ml) 143C143 1
Reagent 2 (25ml) 143C144 1
Electrode filling solution (25ml) 143C145 1
Micropipette (0.5ml) 0SZ00013 1
Liquid measuring pipette (5ml) 0SZ00014 1
Pipette (2ml) 0SZ00015 1
Pipette for filling solution replenishment 0SZ00016 1
User manual 0PA00064 1
Source: Public information from the HACH Water Quality website
Recomendados similares
HACHSerie de tiras reactivas para análisis de agua
HACHDigestor (digestor rápido de COD)
HACHAnalizador electroquímico multicanal
HACHMedidor de bolsillo de agua Pro/Pro+
HACHColorímetro de líquidos
HACHAnalizador portátil de toxicidad del agua
HACHValorador potenciométrico automático serie 1000