Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

COD-60A Permanganate Index Analyzer

COD-60A Permanganate Index Analyzer

COD-60A Permanganate Index Analyzer

HACH COD
The COD-60A permanganate index analyzer uses the acidic (alkaline) potassium permanganate titration method with an integrated heating/titration measurement system. A proprietary control method automates the permanganate index measurement process. Simple and fast to operate.

Application industries:

The COD-60A permanganate index analyzer can be used for the determination of oxygen demand / permanganate index in drinking water, surface water, groundwater, seawater, industrial water, and other fields.

Instrument features:

1) The COD-60A permanganate index analyzer uses the accurate coulometric titration method. It responds sensitively and provides accurate data.

2) The digestion time of this permanganate index analyzer is adjustable within a range of approximately 10 to 800 seconds. The permanganate index measurement data can be obtained in about 5 to 10 minutes, making it convenient and quick.

3) Multiple ranges, direct reading of COD values: The range is set according to the dilution ratio, allowing direct reading of the COD value of the undiluted original solution without conversion.

4) Simple operation: The measurement unit is integrated, combining oxidation and titration processing steps. After setting the instrument, one-touch operation automatically completes the entire process from zero calibration, oxidation, and titration to data printing.

5) Convertible to standard method measured values: Calibration and coefficient adjustment can be performed using the standard method. By determining in advance the correlation between the laboratory standard analytical method and the COD-60A permanganate index analyzer, and inputting the linear regression equation, converted values for the standard analytical method can be obtained.

6) Automatic standard program control reduces operating errors: This permanganate index analyzer uses a proprietary system control to automatically perform steps such as oxidation state (heating/cooling) and titration. It automatically controls temperature and, based on coulometric titration, performs titration using self-cleaning electrodes. This reduces human errors between operators.

7) Various maintenance/inspection functions: The COD-60A permanganate index analyzer uses an electrode cleaning mode and a self-check titration mode, making maintenance and inspection work easy.

8) Data storage function (100 sets), built-in printer, and clock: The permanganate index measurement results can be printed after measurement is completed, and historical data can be displayed or printed later.

Technical specifications
Measurement method:    Acidic (or alkaline) potassium permanganate method
Measurement principle:    Coulometric titration (endpoint detection by redox potential method)
Digestion time:    Adjustable from 10 to 800 s
Titration temperature:   65℃
Display:    Graphic LCD display
                 During measurement: real-time display of sequence status, sample solution temperature, titration curve, etc.
                 Error messages: titration failure, blank error, out of effective range
Measurement range:    Standard: 0~20/40/100/200/400/1000mg/L
                     Arbitrary: 0~(10~2000mg/L settable)
                     Dilution required for 0~20mg/L and above
Repeatability:    ±2%FS
Resolution:    0.01mg/L
Program control:    Fully automatic measurement processing from oxidation to titration (acidic method only)
Calculation functions:    Regression formula conversion function
                     Statistical calculation (average value)
                     Automatic input of blank value (or manual input)
Data storage:    100 data records (measurement time, sample number, result)
Printer:    Built-in
Output:    RS-232C, external printer
Power supply:    AC220V50/60Hz
Weight:    Main unit: approx. 3.5kg

Related reagents

Order No. Description Parameters Analysis method Packaging Range Guaranteed shelf life (days)
2125925-CN Chemical oxygen demand (COD) digestion reagent, high range, HW, pk/25 COD (chemical oxygen demand) 8000 DR800 low range, medium range, high range 25/pk 0-150mg/L, COD 150
2125825-CN rr Chemical oxygen demand (COD) digestion reagent, low range, HW, pk/25 Chemical oxygen demand Chemical oxygen demand (COD) 8000 3-150mg/L
Chemical oxygen demand (COD) 8000 0-150mg/L
Chemical oxygen demand (COD) 8000 3-150mg/L low range
Chemical oxygen demand (COD) 8000 20-1500mg/L
Chemical oxygen demand (COD) 8000 20-1,500mg/L
25/pk 3-150mg/L, COD 150
2415925-CN rr Chemical oxygen demand (COD) digestion reagent, high range+, pk/25 - Chemical oxygen demand (COD) 8000 200-15,000mg/L
Chemical oxygen demand (COD) 8000 0-15,000mg/L
- 200-15,000mg/L 150
TNT820-CN rr Chemical oxygen demand (COD), TNT+, ultra-low range (1.0-60mg/L), pk/24 COD (chemical oxygen demand) 10211 TNTplus ultra-low range - 1.0-60.0mg/L 150
2415825-CN rr Chemical oxygen demand (COD) digestion reagent, ultra-low range, pk/25 COD (chemical oxygen demand) 8000 digestion colorimetric - 0.7-40.0mg/L 150

Ordering guide
Complete unit Order No.: COD60A-2-6
Standard accessories
Name                                                             Order No.                                          Quantity
Measuring vessel, support rod, and positioner                          0KK00001                                        1
Electrode sheath                                                  0IB00011                                         1
Measurement electrode 1                                                0LA00001                                        1
Measurement electrode 2                                                0LA00002                                        1
Measuring cell                                                     0DA00002                                        2
Measuring cell holder                                                  0LZ00003                                        1
Stirring bar                                                     0SE00001                                         1
Reagent 1 (100ml)                                           143C143                                          1
Reagent 2 (25ml)                                             143C144                                          1
Electrode filling solution (25ml)                                     143C145                                          1
Micropipette (0.5ml)                                        0SZ00013                                        1
Liquid measuring pipette (5ml)                                       0SZ00014                                         1
Pipette (2ml)                                              0SZ00015                                         1
Pipette for filling solution replenishment                                      0SZ00016                                         1
User manual                                                   0PA00064                                         1