SC200 Universal Controller: 24 V DC with one analog pH/ORP/DO sensor input, HART and two 4-20mA outputs
HACH LXV404.99.75102
One Controller for All of Your Water Testing Needs

产品概述

One Controller for All of Your Water Testing Needs

The Hach SC200 Universal Controller is the most versatile controller on the market. It allows the use of both digital and analog sensors, to provide compatibility with the broadest range of sensors. The SC200 replaces the Hach SC100 digital and GLI53 analog controllers with advanced features for easier operator use. Customers may add communication modules for a variety of protocols including Modbus RTU, Profibus DPV1, and HART. The SC200 is compatible with sensors for over 17 parameters, including pH/ORP, dissolved oxygen, chlorine, conductivity, flow, turbidity, and much more.

主要特点

  • Maximum Versatility:The SC200 will connect to over 30 digital and analog sensor families, covering 17 different parameters. A variety of modules are available for a numerous communication protocols including MODBUS RTU, Profibus DPV1, and HART. 4-20mA outputs transmit primary and secondary measurement values.
  • Intuitive and Easy to Use:Simple user interface allows users to easily configure controller and sensor options. Guided calibration options ensure operators can quickly and easily calibrate sensors. SD card reader allows settings from one controller to be quickly transferred to other controllers in the plant, saving time.
  • Confidence in Results:Visual warning system provides critical alerts to users immediately. Password protected SD card reader offers peace of mind and security, while providing a simple solution for data transfer and storage.
  • Broadest Range of Sensors:Use the SC200 Universal Controller in combination with over 30 different sensor families covering 17 different parameters

技术参数

参数名称说明
Operational ModePrimary or secondary measurement, calculated value (dual channel only) or timer
Analog Output Functional ModeLinear, logarithmic, bi-linear, PID
Analog OutputsTwo (Five with optional expansion module) isolated current outputs, max 550 Ω, Accuracy:± 0.1% of FS (20mA) at 25 °C, ± 0.5% of FS over -20 °C to 60 °C range Operational Mode: measurement or calculated value
CommunicationMODBUS RS232/RS485, PROFIBUS DPV1, or HART 7.2 optional
CommunicationHART and two 4-20mA outputs
Communication CapabilitiesHART
Conduit Openings1/2" NPT Conduit
Dimensions (H x W x D)144 mm x 144 mm x 181 mm
DisplayGraphic dot matrix LCD with LED backlighting, transreflective
Display Resolution240 x 160 pixels
Display Size48 x 68 mm
Electrical CertificationsEMC CE compliant for conducted and radiated emissions: - CISPR 11 (Class A limits) - EMC Immunity EN 61326-1 (Industrial limits) Safety cETLus safety mark for: - General Locations per ANSI/UL 61010-1 & CAN/CSA C22.2. No. 61010-1 - Hazardous Location Class I, Division 2, Groups A,B,C & D (Zone 2, Group IIC) per FM 3600 / FM 3611 & CSA C22.2 No. 213 M1987 with approved options and appropriately rated Class I, Division 2 or Zone 2 sensors cULus safety mark - General Locations per UL 61010-1 & CAN/CSA C22.2. No. 61010-1
Enclosure RatingIP66 / NEMA 4X
Length181 mm
Manual LanguagesBulgarian, Chinese (PRC), Croatian, Czech, Danish, Dutch, English, Estonian, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Lithuanian, Polish, Portuguese (Brazil), Portuguese (Portugal), Romanian, Russian, Slovak, Slovenian, Spanish, Swedish, Thai, Turkish
Material EnclosuresPolycarbonate Aluminium (powder coated) Stainless steel
Mounting ConfigurationsWall, pole, and panel mounting
Operating Temperature Range-20 - 60 °C at 0 - 95% RH (non-condensing)
Power Options24 VDC
Power Requirements (Hz)50 - 60 Hz
Power Requirements (Voltage)24 VDC
Power Supply24 VDC, with 2x strain relief's
Relay FunctionsScheduler (timer), alarm, feeder control, event control, pulse width modulation, frequency control, and warning
RelaysFour electromechanical SPDT (Form C) contacts, 1200 W, 5 A
Security Levels2 password-protected levels
Sensor Input #1Analog pH/ORP/DO
Storage Conditions-20 °C to 70 °C
Warranty24 months
Weight1.70 kg
What's included?Controller, Mounting Hardware, Basic User Manual

应用领域

Municipal Water

同系列其他配置

型号
LXV404.99.05112SC200 Universal Controller: 100-240 V AC with two analog pH/ORP/DO sen
LXV404.99.05102SC200 Universal Controller: 100-240 V AC with one analog pH/ORP/DO sen
LXV404.99.05202SC200 Universal Controller: 100-240 V AC with one analog conductivity
LXV404.99.05502SC200 Universal Controller: 100-240 V AC with one digital sensor input
LXV404.99.05512SC200 Controller, 100-240 VAC, one digital sensor input, one analog pH
LXV404.99.05552SC200 Universal Controller: 100-240 V AC with two digital sensor input
LXV404.99.75202SC200 Universal Controller: 24 V DC with one analog conductivity senso
LXV404.99.75222SC200 Universal Controller: 24 V DC with two analog conductivity senso
LXV404.99.75502SC200 Universal Controller: 24 V DC with one digital sensor input, HAR
LXV404.99.75552SC200 Universal Controller: 24 V DC with two digital sensor inputs, HA

资料下载

11 modelos · clic para contraer