产品概述
One Controller for All of Your Water Testing Needs
The Hach SC200 Universal Controller is the most versatile controller on the market. It allows the use of both digital and analog sensors, to provide compatibility with the broadest range of sensors. The SC200 replaces the Hach SC100 digital and GLI53 analog controllers with advanced features for easier operator use. Customers may add communication modules for a variety of protocols including Modbus RTU, Profibus DPV1, and HART. The SC200 is compatible with sensors for over 17 parameters, including pH/ORP, dissolved oxygen, chlorine, conductivity, flow, turbidity, and much more.
主要特点
- Maximum Versatility:The SC200 will connect to over 30 digital and analog sensor families, covering 17 different parameters. A variety of modules are available for a numerous communication protocols including MODBUS RTU, Profibus DPV1, and HART. 4-20mA outputs transmit primary and secondary measurement values.
- Intuitive and Easy to Use:Simple user interface allows users to easily configure controller and sensor options. Guided calibration options ensure operators can quickly and easily calibrate sensors. SD card reader allows settings from one controller to be quickly transferred to other controllers in the plant, saving time.
- Confidence in Results:Visual warning system provides critical alerts to users immediately. Password protected SD card reader offers peace of mind and security, while providing a simple solution for data transfer and storage.
- Broadest Range of Sensors:Use the SC200 Universal Controller in combination with over 30 different sensor families covering 17 different parameters
技术参数
| 参数名称 | 说明 |
|---|---|
| Operational Mode | Primary or secondary measurement, calculated value (dual channel only) or timer |
| Analog Output Functional Mode | Linear, logarithmic, bi-linear, PID |
| Analog Outputs | Two (Five with optional expansion module) isolated current outputs, max 550 Ω, Accuracy:± 0.1% of FS (20mA) at 25 °C, ± 0.5% of FS over -20 °C to 60 °C range Operational Mode: measurement or calculated value |
| Communication | MODBUS RS232/RS485, PROFIBUS DPV1, or HART 7.2 optional |
| Communication | HART and two 4-20mA outputs |
| Communication Capabilities | HART |
| Conduit Openings | 1/2" NPT Conduit |
| Dimensions (H x W x D) | 144 mm x 144 mm x 181 mm |
| Display | Graphic dot matrix LCD with LED backlighting, transreflective |
| Display Resolution | 240 x 160 pixels |
| Display Size | 48 x 68 mm |
| Electrical Certifications | EMC CE compliant for conducted and radiated emissions: - CISPR 11 (Class A limits) - EMC Immunity EN 61326-1 (Industrial limits) Safety cETLus safety mark for: - General Locations per ANSI/UL 61010-1 & CAN/CSA C22.2. No. 61010-1 - Hazardous Location Class I, Division 2, Groups A,B,C & D (Zone 2, Group IIC) per FM 3600 / FM 3611 & CSA C22.2 No. 213 M1987 with approved options and appropriately rated Class I, Division 2 or Zone 2 sensors cULus safety mark - General Locations per UL 61010-1 & CAN/CSA C22.2. No. 61010-1 |
| Enclosure Rating | IP66 / NEMA 4X |
| Length | 181 mm |
| Manual Languages | Bulgarian, Chinese (PRC), Croatian, Czech, Danish, Dutch, English, Estonian, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Lithuanian, Polish, Portuguese (Brazil), Portuguese (Portugal), Romanian, Russian, Slovak, Slovenian, Spanish, Swedish, Thai, Turkish |
| Material Enclosures | Polycarbonate Aluminium (powder coated) Stainless steel |
| Mounting Configurations | Wall, pole, and panel mounting |
| Operating Temperature Range | -20 - 60 °C at 0 - 95% RH (non-condensing) |
| Power Options | 24 VDC |
| Power Requirements (Hz) | 50 - 60 Hz |
| Power Requirements (Voltage) | 24 VDC |
| Power Supply | 24 VDC, with 2x strain relief's |
| Relay Functions | Scheduler (timer), alarm, feeder control, event control, pulse width modulation, frequency control, and warning |
| Relays | Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A |
| Security Levels | 2 password-protected levels |
| Sensor Input #1 | Analog Conductivity |
| Sensor Input #2 | Analog Conductivity |
| Storage Conditions | -20 °C to 70 °C |
| Warranty | 24 months |
| Weight | 1.70 kg |
| What's included? | Controller, Mounting Hardware, Basic User Manual |
应用领域
Municipal Water
同系列其他配置
| 型号 | |
|---|---|
| LXV404.99.05112 | SC200 Universal Controller: 100-240 V AC with two analog pH/ORP/DO sen |
| LXV404.99.05102 | SC200 Universal Controller: 100-240 V AC with one analog pH/ORP/DO sen |
| LXV404.99.05202 | SC200 Universal Controller: 100-240 V AC with one analog conductivity |
| LXV404.99.05502 | SC200 Universal Controller: 100-240 V AC with one digital sensor input |
| LXV404.99.05512 | SC200 Controller, 100-240 VAC, one digital sensor input, one analog pH |
| LXV404.99.05552 | SC200 Universal Controller: 100-240 V AC with two digital sensor input |
| LXV404.99.75102 | SC200 Universal Controller: 24 V DC with one analog pH/ORP/DO sensor i |
| LXV404.99.75202 | SC200 Universal Controller: 24 V DC with one analog conductivity senso |
| LXV404.99.75502 | SC200 Universal Controller: 24 V DC with one digital sensor input, HAR |
| LXV404.99.75552 | SC200 Universal Controller: 24 V DC with two digital sensor inputs, HA |
资料下载
- Monitoring Iron Transport in the Steam Cycle via Grab Sample and Online Methods
- Monitoring Iron Transport in the Steam Cycle via Grab Sample and Online Methods
- Monitorización del transporte de hierro en el ciclo de vapor mediante muestras en el ciclo de vapor mediante muestras
- Introduction to Hach Services
- Care Advantage Flyer : Complete service solution for all your instruments
- Care Advantage Brochure : Complete service solution for all your instruments
- BOD, COD and TOC Monitoring in Pulp & Paper Wastewater
- SC200 Universal Controller Data Sheet
Recomendados similares
HACHConductivity Standard Solutions, 1000 µS/cm (491 mg/L NaCl)
HACHPolymetron Conductivity Module for SC200 Ultra Pure Controller
HACH1990 µS/cm Conductivity Standard; (995 mg/L TDS, 1000 mg/L NaCl), 1L
HACHRadiometer Analytical CDC565 Conductivity Cell (4-pole Pt sensor, k = 1.0 cm-1, epoxy body)
HACHCDW97-K10, Conductivity probe for salinity and brackish water
Solution, Conductivity Assembly
HACHRadiometer Conductivity Cells
HACH