Instrumentación · Ingeniería · Paquete · PLC
0755-82221901 sales@ainstru.com

HI98194

HI98194

Analizador portátil multiparamétrico de calidad del aguaEn stock (3)

Medidor multiparamétrico de calidad del agua (12 parámetros)

Product Overview

Measuring range: 0.00 to 14.00 pH, pH-mV: ± 600.0 mV, mV/ORP: ± 2000.0 mV, EC: 0 to 200 mS/cm, TDS: 0.0 to 400.0 ppt (g/L), Resistivity: 0 to 1.0000 MΩ•cm, Salinity: 0.00 to 70.00 PSU,  Seawater specific gravity: 0.0 to 50.0 σt, σ₀, σ₁₅, DO: 0.0 to 500.0%, 0.00 to 50.00 ppm (mg/L)

Portable high-precision professional multi-parameter analyzer, compliant with IP67 international waterproof standard, for fast and accurate measurement of 12 routine important water quality parameters including acidity pH-pH-mV conversion-oxidation reduction ORP-conductivity EC-resistivity-total dissolved solids TDS-salinity-dissolved oxygen-dissolved oxygen saturation-seawater specific gravity-atmospheric pressure-temperature, with automatic range recognition and unit conversion; new appearance design, on-screen calibration procedure prompts, GLP function, quick query of relevant data, acidity check function, automatic recognition calibration and user-defined calibration, automatic endpoint locking function, USB data interface, large-capacity data storage, good data management

Backlit graphic LCD display - The HI98194 features a backlit graphic LCD with on-screen help function and can display up to 12 parameters simultaneously. The graphic display allows the use of virtual keys to provide an intuitive user interface.

Waterproof protection - The meter is enclosed in an IP67-rated waterproof housing and can withstand immersion in water up to 1 meter deep for up to 30 minutes. The probe has IP68 protection and can be continuously immersed in water.

Quick-connect digital probe - The HI7698194 probe features a quick-connect DIN connector for waterproof connection to the meter.

Color-coded, field-replaceable sensors - Quickly and easily replace sensors using field-replaceable screw-type connectors that are color-coded for easy identification of sensor ports.

Automatic sensor recognition - The probe and meter automatically recognize connected sensors. Any unused port on the probe will not display parameters or allow configuration of that parameter.

Automatic temperature compensation - The integrated temperature sensor allows automatic temperature compensation for pH, conductivity, and dissolved oxygen measurements. 

Automatic barometric pressure compensation - The meter has a built-in barometer, and the user can select the unit used for dissolved oxygen pressure compensation.

Standard or quick calibration - Quick calibration allows fast single-point calibration for pH, conductivity, and dissolved oxygen. The standard pH calibration option can be used to calibrate three points selected from five standard buffers and one custom buffer. Conductivity calibration is a single-point calibration from six standard selections or one custom standard. Dissolved oxygen calibration can calibrate up to two standard points or a single custom point.

GLP data - The HI98194 includes a GLP function that allows the user to view calibration data and expiration information by touching a key. Calibration data includes date, time, buffer/standard solution used for calibration, and slope characteristics.

Data logging - The HI98194 allows the user to store up to 45,000 continuous or on-demand log samples, with logging intervals from one second to three hours.

Intuitive keypad - The installed rubber keypad features dedicated power, backlight, up/down arrows, help, and alphanumeric characters. The meter also has two virtual soft keys that guide the user through configuration, meter setup, and data logging for each parameter. The interface is intuitive for any user's level of experience.

Dedicated help key - Context-sensitive help is always available through the dedicated "HELP" key. Clear tutorial messages and instructions are provided on the screen to quickly guide the user through setup and calibration. The displayed help information is relevant to the setting/option being viewed.

PC connection - Using the included HI920015 micro USB cable and HI9298194 software, logged data can be transferred to a Windows-compatible PC.

Long battery life - The meter's display has a battery icon indicator to show remaining power. The meter uses four 1.5V AA batteries and provides up to 360 hours of battery life. 

Rugged thermoformed carrying case - The HI98194 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The interior compartments of the case are thermoformed to securely hold and protect all components.

Order No. HI98194
Product name Multi-parameter pH/ORP/EC/TDS/Salinity/DO/Pressure/Temperature Waterproof Meter - HI98194
Quote required Yes
pH range 0.00 to 14.00 pH
pH resolution 0.01 pH
pH accuracy ±0.02 pH
pH calibration Automatic one-point, two-point, or three-point, with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
pH calibration ±2000.0 mV
ORP resolution 0.1 mV
ORP accuracy ±1.0 mV
ORP calibration Automatic at one custom point (relative mV)
mV range ±600.0 mV
mV resolution 0.1 mV
mV accuracy ±0.5 mV
EC range 0 to 200 mS/cm (absolute EC up to 400 mS/cm)
EC resolution Autoranging
EC accuracy ±1% of reading or ±1 μS/cm, whichever is greater
EC calibration Automatic single-point, with six standard solutions (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or a custom point
TDS range 0 to 400000 ppm (mg/L); (maximum depends on TDS factor)
TDS resolution Manual
TDS accuracy ±1% of reading or ±1 ppm (mg/L), whichever is greater
TDS calibration Based on conductivity or salinity calibration
Salinity (PSU) range 0.00 to 70.00 PSU
Salinity (PSU) resolution 0.01 PSU
Salinity (PSU) accuracy ±2% of reading or ±0.01 PSU, whichever is greater
Salinity (PSU) calibration Based on conductivity calibration
Salinity (seawater sigma) range 0.0 to 50.0 σt, σ₀, σ₁₅
Salinity (seawater sigma) resolution 0.1 σt, σ₀, σ₁₅
Salinity (seawater sigma) accuracy ±1 σt, σ₀, σ₁₅
Salinity (seawater sigma) calibration Based on conductivity or salinity calibration
Resistivity range 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm
Resistivity resolution Depends on resistivity reading
Resistivity calibration Based on conductivity calibration
Dissolved oxygen measurement type Polarographic
Dissolved oxygen range 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
Dissolved oxygen resolution 0.1%; 0.01 ppm (mg/L)
Dissolved oxygen accuracy 0.0 to 300.0% saturation
Dissolved oxygen calibration Automatic one-point or two-point at 0 and 100% or 100%, or one custom point
Dissolved oxygen temperature compensation Automatic from 0.0 to 50.0 °C (32.0 to 122.0 °F)
Barometric pressure compensation Automatic from 450 to 850 mmHg
Salinity compensation Automatic from 0 to 70 g/L
Temp. range Temp. range
Temperature resolution 0.01 K, 0.01 °C, 0.01 °F
Temperature accuracy ±0.15 °C; ±0.27 °F; ±0.15  K
Temperature calibration Automatic at one custom point
Temperature compensation Automatic from -5 to 55 °C (23 to 131 °F)
Logging memory 45,000 records (continuous logging or on-demand logging of all parameters)
Logging interval One second to three hours
Connectivity USB to PC, with HI9298194 Hanna software installed
Battery type/life 1.5V AA batteries (4)/approximately 360 hours of continuous use without backlight (50 hours with backlight)
Environment 0 to 50°C (32 to 122°F); relative humidity 100% (IP67)
Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4 in)
Weight 400 g (14.2 oz)
Ordering information HI98194 is supplied with HI7698194 probe, HI7698194-1 pH / ORP sensor, HI7698194-3 EC sensor, HI7698194-2 DO sensor, HI 76981942 probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), sensor O-rings (5), syringe with lubricating grease, HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, rugged carrying case with custom thermoformed insert.
Atmospheric pressure range 450 to 850 mm Hg; 17.72 to 33.46 inHg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Atmospheric pressure resolution 0.1 mm Hg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Atmospheric pressure accuracy ±3 mm Hg, within ±15% of calibration point
Atmospheric pressure calibration Automatic at one custom point
Tratamiento de Aguas Residuales Municipales

Tratamiento de Aguas Residuales Municipales — Hanna: caso de configuración desde stock

Resumen del proyecto

La instalación está en las etapas de entrada, biológica y salida de una planta municipal. El cliente quería configurar bien Hanna en la planta existente, con el objetivo de análisis portátil y de laboratorio con instrumentos Hanna.

Retos técnicos

Lo que realmente da problemas es alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal, y los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Todo ello implica que la configuración de Hanna deba incluir selección por parámetros, precisión y portabilidad.

Configuración

El suministro y la instalación se organizaron por la vía de stock: configurar desde stock y entregado con rapidez. En planta esto supuso selección por parámetros, precisión y portabilidad; se revisó línea a línea: cumplimiento estable del nivel 1A y reporte de datos en línea.

Comportamiento

Tras la puesta en marcha el resultado es resultados in situ, con menos verificaciones de laboratorio, y las lecturas se usan ya para ajustar el proceso.

Alimentación y Bebidas

Alimentación y Bebidas — Hanna: caso de configuración desde stock

Situación en planta

Se trata de un cliente del sector Alimentación y Bebidas cuya planta está en las etapas de dosificación, pasteurización, llenado y limpieza CIP. La tarea principal era análisis portátil y de laboratorio con instrumentos Hanna.

El problema

La dificultad está en jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos; a la vez, las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente. Por eso la especificación implica selección por parámetros, precisión y portabilidad.

Qué hicimos

Adoptamos un enfoque de stock: configurar desde stock y entregado con rapidez. La entrega se construyó en torno a selección por parámetros, precisión y portabilidad; se verificó punto por punto: requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.

Resultado operativo

En servicio el sistema responde a lo previsto: resultados in situ, con menos verificaciones de laboratorio, con un mantenimiento rutinario notablemente menor.

Química y Farmacéutica

Química y Farmacéutica — Hanna: caso de configuración desde stock

Contexto de aplicación

reactores, vasijas de dosificación y tanques de producto terminado es un servicio típico de Química y Farmacéutica. El proyecto partió de Hanna, centrándose en análisis portátil y de laboratorio con instrumentos Hanna.

Limitaciones del proceso

la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, y medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas no hace sino acentuarlo. Por eso la especificación de Hanna debe cubrir selección por parámetros, precisión y portabilidad.

Enfoque de suministro

La entrega se gestionó como stock: configurar desde stock y entregado con rapidez. La ejecución se centró en selección por parámetros, precisión y portabilidad, junto con certificación Ex y trazabilidad de datos según GMP.

Resultados en campo

La operación evidencia el beneficio: resultados in situ, con menos verificaciones de laboratorio, con una confianza claramente mayor en este punto de medición.

Energía y Electricidad

Energía y Electricidad — Hanna: caso de configuración desde stock

Perfil del cliente

El entorno típico en Energía y Electricidad es agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El punto de medición es Hanna; el foco es análisis portátil y de laboratorio con instrumentos Hanna.

Dificultades clave

Las condiciones son alta temperatura y presión, con vapor y agua salina y, encima, deriva a alta temperatura y presión, con paradas no programadas muy costosas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de selección por parámetros, precisión y portabilidad.

Implementación

El alcance se canalizó por la vía de stock: configurar desde stock y entregado con rapidez. Técnicamente se apoya en selección por parámetros, precisión y portabilidad, y en estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.

Beneficio para el cliente

En la práctica esto significa resultados in situ, con menos verificaciones de laboratorio, lo que redujo la carga del equipo de mantenimiento.