Приборы · Инжиниринг · Комплектация · ПЛК
0755-82221901 sales@ainstru.com
HI98194

Портативный многопараметрический анализатор качества водыВ наличии (3)

Многопараметрический прибор для анализа воды (12 параметров)

Product Overview

Measuring range: 0.00 to 14.00 pH, pH-mV: ± 600.0 mV, mV/ORP: ± 2000.0 mV, EC: 0 to 200 mS/cm, TDS: 0.0 to 400.0 ppt (g/L), Resistivity: 0 to 1.0000 MΩ•cm, Salinity: 0.00 to 70.00 PSU,  Seawater specific gravity: 0.0 to 50.0 σt, σ₀, σ₁₅, DO: 0.0 to 500.0%, 0.00 to 50.00 ppm (mg/L)

Portable high-precision professional multi-parameter analyzer, compliant with IP67 international waterproof standard, for fast and accurate measurement of 12 routine important water quality parameters including acidity pH-pH-mV conversion-oxidation reduction ORP-conductivity EC-resistivity-total dissolved solids TDS-salinity-dissolved oxygen-dissolved oxygen saturation-seawater specific gravity-atmospheric pressure-temperature, with automatic range recognition and unit conversion; new appearance design, on-screen calibration procedure prompts, GLP function, quick query of relevant data, acidity check function, automatic recognition calibration and user-defined calibration, automatic endpoint locking function, USB data interface, large-capacity data storage, good data management

Backlit graphic LCD display - The HI98194 features a backlit graphic LCD with on-screen help function and can display up to 12 parameters simultaneously. The graphic display allows the use of virtual keys to provide an intuitive user interface.

Waterproof protection - The meter is enclosed in an IP67-rated waterproof housing and can withstand immersion in water up to 1 meter deep for up to 30 minutes. The probe has IP68 protection and can be continuously immersed in water.

Quick-connect digital probe - The HI7698194 probe features a quick-connect DIN connector for waterproof connection to the meter.

Color-coded, field-replaceable sensors - Quickly and easily replace sensors using field-replaceable screw-type connectors that are color-coded for easy identification of sensor ports.

Automatic sensor recognition - The probe and meter automatically recognize connected sensors. Any unused port on the probe will not display parameters or allow configuration of that parameter.

Automatic temperature compensation - The integrated temperature sensor allows automatic temperature compensation for pH, conductivity, and dissolved oxygen measurements. 

Automatic barometric pressure compensation - The meter has a built-in barometer, and the user can select the unit used for dissolved oxygen pressure compensation.

Standard or quick calibration - Quick calibration allows fast single-point calibration for pH, conductivity, and dissolved oxygen. The standard pH calibration option can be used to calibrate three points selected from five standard buffers and one custom buffer. Conductivity calibration is a single-point calibration from six standard selections or one custom standard. Dissolved oxygen calibration can calibrate up to two standard points or a single custom point.

GLP data - The HI98194 includes a GLP function that allows the user to view calibration data and expiration information by touching a key. Calibration data includes date, time, buffer/standard solution used for calibration, and slope characteristics.

Data logging - The HI98194 allows the user to store up to 45,000 continuous or on-demand log samples, with logging intervals from one second to three hours.

Intuitive keypad - The installed rubber keypad features dedicated power, backlight, up/down arrows, help, and alphanumeric characters. The meter also has two virtual soft keys that guide the user through configuration, meter setup, and data logging for each parameter. The interface is intuitive for any user's level of experience.

Dedicated help key - Context-sensitive help is always available through the dedicated "HELP" key. Clear tutorial messages and instructions are provided on the screen to quickly guide the user through setup and calibration. The displayed help information is relevant to the setting/option being viewed.

PC connection - Using the included HI920015 micro USB cable and HI9298194 software, logged data can be transferred to a Windows-compatible PC.

Long battery life - The meter's display has a battery icon indicator to show remaining power. The meter uses four 1.5V AA batteries and provides up to 360 hours of battery life. 

Rugged thermoformed carrying case - The HI98194 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The interior compartments of the case are thermoformed to securely hold and protect all components.

Order No. HI98194
Product name Multi-parameter pH/ORP/EC/TDS/Salinity/DO/Pressure/Temperature Waterproof Meter - HI98194
Quote required Yes
pH range 0.00 to 14.00 pH
pH resolution 0.01 pH
pH accuracy ±0.02 pH
pH calibration Automatic one-point, two-point, or three-point, with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
pH calibration ±2000.0 mV
ORP resolution 0.1 mV
ORP accuracy ±1.0 mV
ORP calibration Automatic at one custom point (relative mV)
mV range ±600.0 mV
mV resolution 0.1 mV
mV accuracy ±0.5 mV
EC range 0 to 200 mS/cm (absolute EC up to 400 mS/cm)
EC resolution Autoranging
EC accuracy ±1% of reading or ±1 μS/cm, whichever is greater
EC calibration Automatic single-point, with six standard solutions (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or a custom point
TDS range 0 to 400000 ppm (mg/L); (maximum depends on TDS factor)
TDS resolution Manual
TDS accuracy ±1% of reading or ±1 ppm (mg/L), whichever is greater
TDS calibration Based on conductivity or salinity calibration
Salinity (PSU) range 0.00 to 70.00 PSU
Salinity (PSU) resolution 0.01 PSU
Salinity (PSU) accuracy ±2% of reading or ±0.01 PSU, whichever is greater
Salinity (PSU) calibration Based on conductivity calibration
Salinity (seawater sigma) range 0.0 to 50.0 σt, σ₀, σ₁₅
Salinity (seawater sigma) resolution 0.1 σt, σ₀, σ₁₅
Salinity (seawater sigma) accuracy ±1 σt, σ₀, σ₁₅
Salinity (seawater sigma) calibration Based on conductivity or salinity calibration
Resistivity range 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm
Resistivity resolution Depends on resistivity reading
Resistivity calibration Based on conductivity calibration
Dissolved oxygen measurement type Polarographic
Dissolved oxygen range 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
Dissolved oxygen resolution 0.1%; 0.01 ppm (mg/L)
Dissolved oxygen accuracy 0.0 to 300.0% saturation
Dissolved oxygen calibration Automatic one-point or two-point at 0 and 100% or 100%, or one custom point
Dissolved oxygen temperature compensation Automatic from 0.0 to 50.0 °C (32.0 to 122.0 °F)
Barometric pressure compensation Automatic from 450 to 850 mmHg
Salinity compensation Automatic from 0 to 70 g/L
Temp. range Temp. range
Temperature resolution 0.01 K, 0.01 °C, 0.01 °F
Temperature accuracy ±0.15 °C; ±0.27 °F; ±0.15  K
Temperature calibration Automatic at one custom point
Temperature compensation Automatic from -5 to 55 °C (23 to 131 °F)
Logging memory 45,000 records (continuous logging or on-demand logging of all parameters)
Logging interval One second to three hours
Connectivity USB to PC, with HI9298194 Hanna software installed
Battery type/life 1.5V AA batteries (4)/approximately 360 hours of continuous use without backlight (50 hours with backlight)
Environment 0 to 50°C (32 to 122°F); relative humidity 100% (IP67)
Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4 in)
Weight 400 g (14.2 oz)
Ordering information HI98194 is supplied with HI7698194 probe, HI7698194-1 pH / ORP sensor, HI7698194-3 EC sensor, HI7698194-2 DO sensor, HI 76981942 probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), sensor O-rings (5), syringe with lubricating grease, HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, rugged carrying case with custom thermoformed insert.
Atmospheric pressure range 450 to 850 mm Hg; 17.72 to 33.46 inHg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Atmospheric pressure resolution 0.1 mm Hg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Atmospheric pressure accuracy ±3 mm Hg, within ±15% of calibration point
Atmospheric pressure calibration Automatic at one custom point
Городские сточные воды

Городские сточные воды — Hanna: пример комплектации со склада

О проекте

Объект находится на входную, биологическую и выходную стадии городских очистных. Клиент хотел корректно оснастить существующее производство; позиция — Hanna, цель — портативные и лабораторные измерения воды приборами Hanna.

Технические вызовы

Реальная проблема в следующем: высокое содержание взвесей и коррозионных компонентов, большие суточные колебания расхода, и при этом показатели стоков колеблются, датчики зарастают илом и биоплёнкой. Всё это означает, что для конфигурации Hanna главное — подбор по набору параметров, точности и портативности.

Конфигурация

Поставка и монтаж организованы через «склад»: комплектация со склада с быстрой поставкой. На объекте это означало подбор по набору параметров, точности и портативности; построчно сверялось: стабильное соответствие нормам сброса класса 1A и передача данных онлайн.

Работа после ввода

После пусконаладки результат — результат сразу на месте, меньше повторных лабораторных проверок; показания теперь используются для настройки процесса.

Пищевая промышленность

Пищевая промышленность — Hanna: пример комплектации со склада

Ситуация на объекте

Клиент работает в отрасли «Пищевая промышленность», производство расположено на участки дозирования, пастеризации, розлива и CIP-мойки. Главная задача — портативные и лабораторные измерения воды приборами Hanna.

В чём сложность

Сложность в том, что сиропы, молочные продукты и напитки, склонные к отложениям, при жёстких санитарных требованиях; кроме того, частые мойки требуют приборов, стойких к горячим щелочным циклам CIP/SIP. Поэтому ключевое здесь — подбор по набору параметров, точности и портативности.

Что мы сделали

Мы использовали подход «склад» — комплектация со склада с быстрой поставкой. Основа реализации — подбор по набору параметров, точности и портативности; поэтапно проверялось: требования пищевой безопасности и гигиенического исполнения 3-A / EHEDG.

Результат работы

В эксплуатации система ведёт себя как задумано — результат сразу на месте, меньше повторных лабораторных проверок, а объём текущего обслуживания заметно снизился.

Химия и фармацевтика

Химия и фармацевтика — Hanna: пример комплектации со склада

Контекст применения

реакторы, мерные и товарные резервуары — типовые условия отрасли «Химия и фармацевтика». Проект: Hanna; главное — портативные и лабораторные измерения воды приборами Hanna.

Ограничения процесса

коррозия и взрывозащита сокращают срок службы приборов и удорожают простои, а условия «сильно агрессивные среды с растворителями и кристаллизацией, частично во взрывоопасных зонах» только усиливают это. Поэтому конфигурация Hanna должна включать подбор по набору параметров, точности и портативности.

Подход к поставке

Формат поставки — «склад»: комплектация со склада с быстрой поставкой. В работе главное — подбор по набору параметров, точности и портативности, а также требования: сертификация Ex и прослеживаемость данных по GMP.

Результаты на объекте

Эксплуатация наглядно показывает результат — результат сразу на месте, меньше повторных лабораторных проверок; доверие к точке измерения заметно выросло.

Энергетика

Энергетика — Hanna: пример комплектации со склада

О клиенте

Типовая площадка в отрасли «Энергетика» — питательная вода котлов, конденсат турбин, системы серо- и азотоочистки. Точка измерения — Hanna; основной акцент — портативные и лабораторные измерения воды приборами Hanna.

Ключевые трудности

Условия: высокие температура и давление, пар и минерализованная вода; вдобавок дрейф при высоких температуре и давлении, крайне дорогие внеплановые остановы — типовое исполнение здесь долго не выдерживает. Решение опирается на следующее: подбор по набору параметров, точности и портативности.

Реализация

Работы шли по каналу «склад»: комплектация со склада с быстрой поставкой. Техническая основа — подбор по набору параметров, точности и портативности; также учтено: соответствие отраслевым нормам и показателям готовности блока.

Выгода клиента

На практике это означает результат сразу на месте, меньше повторных лабораторных проверок, что снизило нагрузку на ремонтный персонал.