Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI98194

HI98194

Portable multiparameter water quality analyzerIn Stock (3)

Multiparameter water quality meter (12 parameters)

Product Overview

Measuring range: 0.00 to 14.00 pH, pH-mV: ± 600.0 mV, mV/ORP: ± 2000.0 mV, EC: 0 to 200 mS/cm, TDS: 0.0 to 400.0 ppt (g/L), Resistivity: 0 to 1.0000 MΩ•cm, Salinity: 0.00 to 70.00 PSU,  Seawater specific gravity: 0.0 to 50.0 σt, σ₀, σ₁₅, DO: 0.0 to 500.0%, 0.00 to 50.00 ppm (mg/L)

Portable high-precision professional multi-parameter analyzer, compliant with IP67 international waterproof standard, for fast and accurate measurement of 12 routine important water quality parameters including acidity pH-pH-mV conversion-oxidation reduction ORP-conductivity EC-resistivity-total dissolved solids TDS-salinity-dissolved oxygen-dissolved oxygen saturation-seawater specific gravity-atmospheric pressure-temperature, with automatic range recognition and unit conversion; new appearance design, on-screen calibration procedure prompts, GLP function, quick query of relevant data, acidity check function, automatic recognition calibration and user-defined calibration, automatic endpoint locking function, USB data interface, large-capacity data storage, good data management

Backlit graphic LCD display - The HI98194 features a backlit graphic LCD with on-screen help function and can display up to 12 parameters simultaneously. The graphic display allows the use of virtual keys to provide an intuitive user interface.

Waterproof protection - The meter is enclosed in an IP67-rated waterproof housing and can withstand immersion in water up to 1 meter deep for up to 30 minutes. The probe has IP68 protection and can be continuously immersed in water.

Quick-connect digital probe - The HI7698194 probe features a quick-connect DIN connector for waterproof connection to the meter.

Color-coded, field-replaceable sensors - Quickly and easily replace sensors using field-replaceable screw-type connectors that are color-coded for easy identification of sensor ports.

Automatic sensor recognition - The probe and meter automatically recognize connected sensors. Any unused port on the probe will not display parameters or allow configuration of that parameter.

Automatic temperature compensation - The integrated temperature sensor allows automatic temperature compensation for pH, conductivity, and dissolved oxygen measurements. 

Automatic barometric pressure compensation - The meter has a built-in barometer, and the user can select the unit used for dissolved oxygen pressure compensation.

Standard or quick calibration - Quick calibration allows fast single-point calibration for pH, conductivity, and dissolved oxygen. The standard pH calibration option can be used to calibrate three points selected from five standard buffers and one custom buffer. Conductivity calibration is a single-point calibration from six standard selections or one custom standard. Dissolved oxygen calibration can calibrate up to two standard points or a single custom point.

GLP data - The HI98194 includes a GLP function that allows the user to view calibration data and expiration information by touching a key. Calibration data includes date, time, buffer/standard solution used for calibration, and slope characteristics.

Data logging - The HI98194 allows the user to store up to 45,000 continuous or on-demand log samples, with logging intervals from one second to three hours.

Intuitive keypad - The installed rubber keypad features dedicated power, backlight, up/down arrows, help, and alphanumeric characters. The meter also has two virtual soft keys that guide the user through configuration, meter setup, and data logging for each parameter. The interface is intuitive for any user's level of experience.

Dedicated help key - Context-sensitive help is always available through the dedicated "HELP" key. Clear tutorial messages and instructions are provided on the screen to quickly guide the user through setup and calibration. The displayed help information is relevant to the setting/option being viewed.

PC connection - Using the included HI920015 micro USB cable and HI9298194 software, logged data can be transferred to a Windows-compatible PC.

Long battery life - The meter's display has a battery icon indicator to show remaining power. The meter uses four 1.5V AA batteries and provides up to 360 hours of battery life. 

Rugged thermoformed carrying case - The HI98194 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The interior compartments of the case are thermoformed to securely hold and protect all components.

Order No. HI98194
Product name Multi-parameter pH/ORP/EC/TDS/Salinity/DO/Pressure/Temperature Waterproof Meter - HI98194
Quote required Yes
pH range 0.00 to 14.00 pH
pH resolution 0.01 pH
pH accuracy ±0.02 pH
pH calibration Automatic one-point, two-point, or three-point, with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
pH calibration ±2000.0 mV
ORP resolution 0.1 mV
ORP accuracy ±1.0 mV
ORP calibration Automatic at one custom point (relative mV)
mV range ±600.0 mV
mV resolution 0.1 mV
mV accuracy ±0.5 mV
EC range 0 to 200 mS/cm (absolute EC up to 400 mS/cm)
EC resolution Autoranging
EC accuracy ±1% of reading or ±1 μS/cm, whichever is greater
EC calibration Automatic single-point, with six standard solutions (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or a custom point
TDS range 0 to 400000 ppm (mg/L); (maximum depends on TDS factor)
TDS resolution Manual
TDS accuracy ±1% of reading or ±1 ppm (mg/L), whichever is greater
TDS calibration Based on conductivity or salinity calibration
Salinity (PSU) range 0.00 to 70.00 PSU
Salinity (PSU) resolution 0.01 PSU
Salinity (PSU) accuracy ±2% of reading or ±0.01 PSU, whichever is greater
Salinity (PSU) calibration Based on conductivity calibration
Salinity (seawater sigma) range 0.0 to 50.0 σt, σ₀, σ₁₅
Salinity (seawater sigma) resolution 0.1 σt, σ₀, σ₁₅
Salinity (seawater sigma) accuracy ±1 σt, σ₀, σ₁₅
Salinity (seawater sigma) calibration Based on conductivity or salinity calibration
Resistivity range 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm
Resistivity resolution Depends on resistivity reading
Resistivity calibration Based on conductivity calibration
Dissolved oxygen measurement type Polarographic
Dissolved oxygen range 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
Dissolved oxygen resolution 0.1%; 0.01 ppm (mg/L)
Dissolved oxygen accuracy 0.0 to 300.0% saturation
Dissolved oxygen calibration Automatic one-point or two-point at 0 and 100% or 100%, or one custom point
Dissolved oxygen temperature compensation Automatic from 0.0 to 50.0 °C (32.0 to 122.0 °F)
Barometric pressure compensation Automatic from 450 to 850 mmHg
Salinity compensation Automatic from 0 to 70 g/L
Temp. range Temp. range
Temperature resolution 0.01 K, 0.01 °C, 0.01 °F
Temperature accuracy ±0.15 °C; ±0.27 °F; ±0.15  K
Temperature calibration Automatic at one custom point
Temperature compensation Automatic from -5 to 55 °C (23 to 131 °F)
Logging memory 45,000 records (continuous logging or on-demand logging of all parameters)
Logging interval One second to three hours
Connectivity USB to PC, with HI9298194 Hanna software installed
Battery type/life 1.5V AA batteries (4)/approximately 360 hours of continuous use without backlight (50 hours with backlight)
Environment 0 to 50°C (32 to 122°F); relative humidity 100% (IP67)
Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4 in)
Weight 400 g (14.2 oz)
Ordering information HI98194 is supplied with HI7698194 probe, HI7698194-1 pH / ORP sensor, HI7698194-3 EC sensor, HI7698194-2 DO sensor, HI 76981942 probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), sensor O-rings (5), syringe with lubricating grease, HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, rugged carrying case with custom thermoformed insert.
Atmospheric pressure range 450 to 850 mm Hg; 17.72 to 33.46 inHg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Atmospheric pressure resolution 0.1 mm Hg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Atmospheric pressure accuracy ±3 mm Hg, within ±15% of calibration point
Atmospheric pressure calibration Automatic at one custom point
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.