Industries:
The DR300 portable colorimeter is suitable for water quality analysis and measurement in drinking water, wastewater, power, food and beverage, industrial and other industries.
Instrument Features:
-
The all-new upgraded DR300 portable colorimeter has been comprehensively improved based on the PCII colorimeter.
-
Direct-reading simple operation reduces operating errors and ensures accurate colorimeter measurement results.
-
The DR300 portable colorimeter is equipped with a large backlit display, rugged housing, and IP67-rated waterproof material, confidently handling various outdoor measurement environments.
-
Optional HACH communication adapter enables wireless connection to mobile phones and the Claros intelligent system, achieving wireless transmission and intelligent management of colorimeter measurement data.*
-
The DR300 portable colorimeter is suitable not only for field water quality measurement but also for laboratory water quality analysis.
Technical Specifications
-
Light source Light-emitting diode (LED)
-
Detector Silicon photodiode
-
Display LCD backlit display
-
Protection class IP67, waterproof at 1 m water depth for 30 minutes
-
Wavelength accuracy Fixed wavelength ±2 nm, varies by model
-
Spectral bandwidth 15 nm
-
Absorbance range 0 - 2.5 Abs
-
Operating environment 0 to 50 °C (32 to 122 °F), 0 to 90% relative humidity, non-condensing
-
Power supply 4 AAA batteries; approximately 5000 tests
-
Data storage Last 50 measurements
-
Sample cell 25 mm (10 mL), 1 cm (10 mL)
-
Weight 0.25 kg (0.55 lb)
-
Dimensions (W x L x H) 69mm x 157mm x 34mm
Related Reagents
| Order No. | Description | Parameter | Measuring method | Packaging | Measuring range | Warranty period (days) |
|---|---|---|---|---|---|---|
| 2105569-CN | DPD free chlorine reagent powder pillows, 10mL, pk/100 | Free chlorine, chlorine dioxide | Chlorine free 8021 DPD 0.02-2.00mg/L Chlorine demand 10223 varies by method Chlorine dioxide 10126 0.05-5.00mg/L ClO₂ Chlorine dioxide 10126 0.04-5.00mg/L ClO₂ Chlorine dioxide 10126 0-5.00mg/L Chlorine free 8021 DPD 0-2.00mg/L DPD method (DR300) |
100/pk | 0.02-2.00mg/L, Cl2 0.02 - 2.00 mg/l or 0.10 - 8.0 mg/l Cl2 (DR300) |
150 |
| 2770900-CN | CL02 DPD powder pillow/Glycine method reagent kit | Chlorine dioxide | Chlorine dioxide 10126 0.04-5.00mg/L ClO₂ Chlorine dioxide 10126 0.05-5.00mg/L ClO₂ Chlorine dioxide 10126 0-5.00mg/L DPD/Glycine method (DR300) |
- | 0.04-5.00mg/L, ClO2 0.05 - 5.00 mg/l ClO2 (DR300) |
150 |
| 2668000-CN | Ammonia nitrogen reagent kit | Ammonia | Ammonia 8155 0.01-0.50mg/L NH₃-N Ammonia 8155 0-0.50mg/L NH₃-N Ammonia 8155 0-1.00mg/L Salicylate method (DR300) |
- | 0.01-0.50mg/L, NH3-N 0.01 - 0.80 mg/L NH3-N (DR300) |
|
| 2105769-CN | FERROVER, iron reagent, pk/100 | Iron | Iron 8008 0.02-3.00mg/L Iron 8008 0.02-5.00mg/L Iron, total 8008 0-3.00mg/L Iron, total 10249 0-300.0mg/L Iron, total 10249 0.1-300.0mg/L FerroVer method (DR300) |
100/pk | 0.02-3.00mg/L, Fe 0.02 - 5.00 mg/l (DR300) |
150 |
| 2106169-CN | NITRAVER5 powder pillows, 10mL, pk/100 | Nitrate | Nitrate 8039 0.3-30.0mg/L NO₃ -N Nitrate 8171 0.1-10.0mg/L NO₃ -N Nitrate 8039 0.3-30.00mg/L NO₃ N Nitrate 8171 0.1-5.0mg/L Nitrate 8039 high range 0-30.0mg/L Nitrate 8171 medium range 0-5.0mg/L Nitrate 8171 0.2-5.0mg/L Cadmium reduction method (DR300) |
100/pk | 0.3-30.0mg/L, NO3-N 0.40 - 30.0 mg/l NO3-N (DR300) |
150 |
| 2106069-CN | PHOSVER3 powder pillows, 10mL, pk/100 | Reactive phosphorus | Phosphorus 8048 0.02-2.50mg/L PO₄ ³⁻ Phosphate 8007 1.0-125mg/L PO₄³- Phosphonate 8007 0.1-2.5mg/L Phosphonate 8007 0.02-2.50mg/L PO₄³- Phosphorus 8048 0-2.50mg/L Phosphonate 8007 0 -2.5 to 0-125mg/L PhosVer 3 (DR300) |
100/pk | 0.02-2.50mg/L, PO4 0.02 - 3.00 mg/l PO43- (DR300) |
150 |
| 2517025-CN | Ozone ACCUVAC, 0-0.75mg/L, pk/25 | Ozone | Ozone 8311 0.01-0.75mg/L O₃ medium range Ozone 8311 0-0.25mg/L Ozone 8311 0-0.75mg/L Ozone 8311 0-1.50mg/L Indigo trisulfonate method (DR300) |
25/pk | 0.01-0.75mg/L, O3 | 150 |
| 2242000-CN | Aluminum reagent kit | Aluminum | Aluminum 8012 0.008-0.800mg/L Aluminum 8012 0-0.80mg/L Aluminum 8012 0.01-0.80mg/L Aluminon method (DR300) |
- | 0.008-0.800mg/L, Al 0.02 - 0.80 mg/l Al3+ (DR300) |
|
| 1407099-CN | DPD free chlorine powder pillows, 25mL, pk/100 | Free chlorine | Chlorine free 8021 DPD 0.02-2.00mg/L Chlorine free and total 8210 0-3.00mg/L Cl₂ Chlorine free 10069 high range 0.1-10.0mg/L Trihalomethane potential 10224 1190-1310mg/L as Cl₂ Chlorine demand 10223 varies by method Chlorine free 10245 medium range 0.05-4.00mg/L Chlorine free 10069, ultra-high range 0.0-10.0mg/L Chlorine free 10245 0-4.00mg/L DPD method (DR300) |
100/pk | 0.1-10.0mg/L, Cl2 0.05 - 4.00 mg/L or 0.1 - 10.0 mg/L Cl2 (DR300) |
150 |
| 2608799-CN | TPTZ iron reagent powder pillows, 10mL, pk/100 | Iron | Iron 8112 0.012-1.800mg/L Iron 8112 0.01-1.70mg/L Iron, total 8112 0-1.80mg/L Iron 8112 0.04-1.80mg/L TPTZ method (DR300) |
100/pk | 0.012-1.800mg/L, Fe 0.01 - 1.70 mg/l (DR300) |
150 |
| 2516025-CN | Ozone ACCUVAC, 0-0.25mg/L, pk/25 | Ozone | Ozone 8311 0.01-0.25mg/L O₃ low range Ozone 8311 0-0.25mg/L Ozone 8311 0-0.75mg/L Ozone 8311 0-1.50mg/L Indigo trisulfonate method (DR300) |
25/pk | 0.01-0.25mg/L, O3 | 150 |
| 2449400-CN | Molybdate reagent kit | Molybdenum, molybdate | Molybdenum 8169 low range 0.02-3.00mg/LMo Molybdenum, molybdate 8169 low range 0-3.00mg/L Ternary complex method (DR300) |
- | 0.02-3.00mg/L, Mo 0.02 - 3.0 mg/l or 0.10 - 12.0 mg/l Mo (DR300) |
150 |
| 2430000-CN | Manganese reagent kit | Manganese | Manganese 8034 high range 0.1-20.0mg/L Manganese 8034 high range 0-20.0mg/L Periodate oxidation method (DR300) |
- | 0.1-20.0mg/L, Mn 0.2 - 20.0 mg/l (DR300) |
150 |
| 2515025-CN | Dissolved oxygen high range, ACCUVAC, pk/25 | Dissolved oxygen | Dissolved oxygen 8166 high range DO 0.3-15.0mg/L O₂ Dissolved oxygen 8333 ultra-high range 1.0-40.0mg/L O₂ Dissolved oxygen 8166 high range 0-15.0mg/L Dissolved oxygen high range DO 0-15mg/L HRDO method (DR300) |
25/pk | 0.3-15.0mg/L, O2 0.2 - 10.0 mg/l O2 (DR300) |
150 |
| 2429300-CN | Zinc reagent kit, 20mL | Zinc | Zinc 8009 0.01-2.00mg/L Zinc 8009 0.01-3.00mg/L Zinc 8009 0-3.00mg/L Zinc 8009 0.02-3.00mg/L Zinc reagent method (DR300) |
- | 0.01-3.00mg/L, Zn 0.02 - 3.0 mg/l Zn2+ (DR300) |
150 |
| 2657512-CN | Phenol red specification indicator, 50mL | pH value | pH 10076 6.5-8.5 pH pH 10076 6.5-8.5 pH units Phenol red (pH) (DR300) |
50 | 6.5-8.5 pH | 90 |
Accessories Information
-
LPV446.99.00012 HACH communication adapter*
-
5953100 Soft carrying case
-
4674300 Alkaline batteries, AAA, 1.5V, 4 pcs
-
2427606 Sample vials, 25X60 mm, 10 ml, with mark, 6 pcs
-
4864302 Sample vials, with cap, 1cm/10ml, 2 pcs
-
5262600 Sample vial caps, 1cm/10ml, 1 pc
-
2401812 Sample vial caps, 1cm/10ml, 12 pcs
-
2635300 SpecCheck secondary standard, gel, DPD chlorine, low range
-
2980500 SpecCheck secondary standard, gel, DPD chlorine, medium range
-
2893300 SpecCheck secondary standard, gel, DPD chlorine, high range
-
2708000 SpecCheck secondary standard, gel, ozone, medium range, 0-0.75 mg/L
-
2507500 SpecCheck secondary standard, gel, monochloramine and free ammonia
Ordering Guide
-
Order No. Description
-
LPV445.80.00110 DR300 - Portable colorimeter, free chlorine/total chlorine
-
LPV445.97.01110 DR300 - Portable colorimeter, bromine
-
LPV445.97.02110 DR300 - Portable colorimeter, nitrate
-
LPV445.97.03110 DR300 - Portable colorimeter, dissolved oxygen
-
LPV445.97.04110 DR300 - Portable colorimeter, ozone
-
LPV445.97.06110 DR300 - Portable colorimeter, phosphate
-
LPV445.97.09110 DR300 - Portable colorimeter, zinc
-
LPV445.97.10110 DR300 - Portable colorimeter, molybdenum
-
LPV445.97.12110 DR300 - Portable colorimeter, chlorine/pH
-
LPV445.97.15110 DR300 - Portable colorimeter, manganese, HR
-
LPV445.97.16110 DR300 - Portable colorimeter, iron (TPTZ method)
-
LPV445.97.22110 DR300 - Portable colorimeter, iron (FerroVer method)
-
LPV445.97.25110 DR300 - Portable colorimeter, aluminum
-
LPV445.97.26110 DR300 - Portable colorimeter, monochloramine/free ammonia
-
LPV445.97.40110 DR300 - Portable colorimeter, ammonia nitrogen
-
LPV445.80.51110 DR300 - Portable colorimeter, chlorine dioxide
-
LPV445.97.62110 DR300 - Portable colorimeter, free chlorine/total chlorine, MR
-
LPV445.97.50110 DR300 - Portable colorimeter, 500 nm
-
LPV445.97.52110 DR300 - Portable colorimeter, 528 nm
-
LPV445.97.60110 DR300 - Portable colorimeter, 600 nm
-
LPV445.97.65110 DR300 - Portable colorimeter, 655 nm
Source: Public information from the HACH Water Quality website
Кейсы
Городские сточные воды — Hach-lab: пример внедрения
О проекте
Объект находится на входную, биологическую и выходную стадии городских очистных. Клиент хотел корректно оснастить существующее производство; позиция — Hach-lab, цель — лабораторный фотометрический и титриметрический анализ воды.
Технические вызовы
Реальная проблема в следующем: высокое содержание взвесей и коррозионных компонентов, большие суточные колебания расхода, и при этом показатели стоков колеблются, датчики зарастают илом и биоплёнкой. Всё это означает, что для конфигурации Hach-lab главное — подбор по методике, потоку проб и комплекту реагентов.
Конфигурация
Поставка и монтаж организованы через «лабораторная линейка»: подбор под методики лаборатории и поток проб. На объекте это означало подбор по методике, потоку проб и комплекту реагентов; построчно сверялось: стабильное соответствие нормам сброса класса 1A и передача данных онлайн.
Работа после ввода
После пусконаладки результат — стандартизованные методики делают данные сопоставимыми между лабораториями; показания теперь используются для настройки процесса.
Пищевая промышленность — Hach-lab: пример внедрения
Ситуация на объекте
Клиент работает в отрасли «Пищевая промышленность», производство расположено на участки дозирования, пастеризации, розлива и CIP-мойки. Главная задача — лабораторный фотометрический и титриметрический анализ воды.
В чём сложность
Сложность в том, что сиропы, молочные продукты и напитки, склонные к отложениям, при жёстких санитарных требованиях; кроме того, частые мойки требуют приборов, стойких к горячим щелочным циклам CIP/SIP. Поэтому ключевое здесь — подбор по методике, потоку проб и комплекту реагентов.
Что мы сделали
Мы использовали подход «лабораторная линейка» — подбор под методики лаборатории и поток проб. Основа реализации — подбор по методике, потоку проб и комплекту реагентов; поэтапно проверялось: требования пищевой безопасности и гигиенического исполнения 3-A / EHEDG.
Результат работы
В эксплуатации система ведёт себя как задумано — стандартизованные методики делают данные сопоставимыми между лабораториями, а объём текущего обслуживания заметно снизился.
Химия и фармацевтика — Hach-lab: пример внедрения
Контекст применения
реакторы, мерные и товарные резервуары — типовые условия отрасли «Химия и фармацевтика». Проект: Hach-lab; главное — лабораторный фотометрический и титриметрический анализ воды.
Ограничения процесса
коррозия и взрывозащита сокращают срок службы приборов и удорожают простои, а условия «сильно агрессивные среды с растворителями и кристаллизацией, частично во взрывоопасных зонах» только усиливают это. Поэтому конфигурация Hach-lab должна включать подбор по методике, потоку проб и комплекту реагентов.
Подход к поставке
Формат поставки — «лабораторная линейка»: подбор под методики лаборатории и поток проб. В работе главное — подбор по методике, потоку проб и комплекту реагентов, а также требования: сертификация Ex и прослеживаемость данных по GMP.
Результаты на объекте
Эксплуатация наглядно показывает результат — стандартизованные методики делают данные сопоставимыми между лабораториями; доверие к точке измерения заметно выросло.
Энергетика — Hach-lab: пример внедрения
О клиенте
Типовая площадка в отрасли «Энергетика» — питательная вода котлов, конденсат турбин, системы серо- и азотоочистки. Точка измерения — Hach-lab; основной акцент — лабораторный фотометрический и титриметрический анализ воды.
Ключевые трудности
Условия: высокие температура и давление, пар и минерализованная вода; вдобавок дрейф при высоких температуре и давлении, крайне дорогие внеплановые остановы — типовое исполнение здесь долго не выдерживает. Решение опирается на следующее: подбор по методике, потоку проб и комплекту реагентов.
Реализация
Работы шли по каналу «лабораторная линейка»: подбор под методики лаборатории и поток проб. Техническая основа — подбор по методике, потоку проб и комплекту реагентов; также учтено: соответствие отраслевым нормам и показателям готовности блока.
Выгода клиента
На практике это означает стандартизованные методики делают данные сопоставимыми между лабораториями, что снизило нагрузку на ремонтный персонал.
Похожие
HACHТермореактор (быстрый реактор COD)
HACHСерия тест-полосок для анализа качества воды
HACHМногоканальный электрохимический анализатор
HACHКарманный анализатор воды Pro/Pro+
HACHИзмеритель цветности жидкости
HACHПортативный анализатор токсичности воды
HACHАвтоматический потенциометрический титратор серии 1000
HACH