Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

DR300 Portable colorimeter

DR300 Portable colorimeter
Portable colorimeter
HACH DR300
The DR300 Portable Colorimeter is a comprehensive upgrade over the PCII colorimeter: direct-reading operation, a larger screen, a brighter backlight, and IP67 waterproof rating, making it a portable single-parameter colorimeter suitable for both laboratory and field water quality measurement.

Industries:

The DR300 portable colorimeter is suitable for water quality analysis and measurement in drinking water, wastewater, power, food and beverage, industrial and other industries.

Instrument Features:

  • The all-new upgraded DR300 portable colorimeter has been comprehensively improved based on the PCII colorimeter.

  • Direct-reading simple operation reduces operating errors and ensures accurate colorimeter measurement results.

  • The DR300 portable colorimeter is equipped with a large backlit display, rugged housing, and IP67-rated waterproof material, confidently handling various outdoor measurement environments.

  • Optional HACH communication adapter enables wireless connection to mobile phones and the Claros intelligent system, achieving wireless transmission and intelligent management of colorimeter measurement data.*

  • The DR300 portable colorimeter is suitable not only for field water quality measurement but also for laboratory water quality analysis.

Technical Specifications

  • Light source    Light-emitting diode (LED)

  • Detector    Silicon photodiode

  • Display    LCD backlit display

  • Protection class    IP67, waterproof at 1 m water depth for 30 minutes

  • Wavelength accuracy    Fixed wavelength ±2 nm, varies by model

  • Spectral bandwidth    15 nm

  • Absorbance range    0 - 2.5 Abs

  • Operating environment    0 to 50 °C (32 to 122 °F), 0 to 90% relative humidity, non-condensing

  • Power supply    4 AAA batteries; approximately 5000 tests

  • Data storage    Last 50 measurements

  • Sample cell    25 mm (10 mL), 1 cm (10 mL)

  • Weight    0.25 kg (0.55 lb)

  • Dimensions (W x L x H)    69mm x 157mm x 34mm

Related Reagents

Order No. Description Parameter Measuring method Packaging Measuring range Warranty period (days)
2105569-CN DPD free chlorine reagent powder pillows, 10mL, pk/100 Free chlorine, chlorine dioxide Chlorine free 8021 DPD 0.02-2.00mg/L
Chlorine demand 10223 varies by method
Chlorine dioxide 10126 0.05-5.00mg/L ClO₂
Chlorine dioxide 10126 0.04-5.00mg/L ClO₂
Chlorine dioxide 10126 0-5.00mg/L
Chlorine free 8021 DPD 0-2.00mg/L
DPD method (DR300)
100/pk 0.02-2.00mg/L, Cl2
0.02 - 2.00 mg/l or 0.10 - 8.0 mg/l Cl2 (DR300)
150
2770900-CN CL02 DPD powder pillow/Glycine method reagent kit Chlorine dioxide Chlorine dioxide 10126 0.04-5.00mg/L ClO₂
Chlorine dioxide 10126 0.05-5.00mg/L ClO₂
Chlorine dioxide 10126 0-5.00mg/L
DPD/Glycine method (DR300)
- 0.04-5.00mg/L, ClO2
0.05 - 5.00 mg/l ClO2 (DR300)
150
2668000-CN Ammonia nitrogen reagent kit Ammonia Ammonia 8155 0.01-0.50mg/L NH₃-N
Ammonia 8155 0-0.50mg/L NH₃-N
Ammonia 8155 0-1.00mg/L
Salicylate method (DR300)
- 0.01-0.50mg/L, NH3-N
0.01 - 0.80 mg/L NH3-N (DR300)
 
2105769-CN FERROVER, iron reagent, pk/100 Iron Iron 8008 0.02-3.00mg/L
Iron 8008 0.02-5.00mg/L
Iron, total 8008 0-3.00mg/L
Iron, total 10249 0-300.0mg/L
Iron, total 10249 0.1-300.0mg/L
FerroVer method (DR300)
100/pk 0.02-3.00mg/L, Fe
0.02 - 5.00 mg/l (DR300)
150
2106169-CN NITRAVER5 powder pillows, 10mL, pk/100 Nitrate Nitrate 8039 0.3-30.0mg/L NO₃ -N
Nitrate 8171 0.1-10.0mg/L NO₃ -N
Nitrate 8039 0.3-30.00mg/L NO₃ ­N
Nitrate 8171 0.1-5.0mg/L
Nitrate 8039 high range 0-30.0mg/L
Nitrate 8171 medium range 0-5.0mg/L
Nitrate 8171 0.2-5.0mg/L
Cadmium reduction method (DR300)
100/pk 0.3-30.0mg/L, NO3-N
0.40 - 30.0 mg/l NO3-N (DR300)
150
2106069-CN PHOSVER3 powder pillows, 10mL, pk/100 Reactive phosphorus Phosphorus 8048 0.02-2.50mg/L PO₄ ³⁻
Phosphate 8007 1.0-125mg/L PO₄³-
Phosphonate 8007 0.1-2.5mg/L
Phosphonate 8007 0.02-2.50mg/L PO₄³-
Phosphorus 8048 0-2.50mg/L
Phosphonate 8007 0 -2.5 to 0-125mg/L
PhosVer 3 (DR300)
100/pk 0.02-2.50mg/L, PO4
0.02 - 3.00 mg/l PO43- (DR300)
150
2517025-CN Ozone ACCUVAC, 0-0.75mg/L, pk/25 Ozone Ozone 8311 0.01-0.75mg/L O₃ medium range
Ozone 8311 0-0.25mg/L
Ozone 8311 0-0.75mg/L
Ozone 8311 0-1.50mg/L
Indigo trisulfonate method (DR300)
25/pk 0.01-0.75mg/L, O3 150
2242000-CN Aluminum reagent kit Aluminum Aluminum 8012 0.008-0.800mg/L
Aluminum 8012 0-0.80mg/L
Aluminum 8012 0.01-0.80mg/L
Aluminon method (DR300)
- 0.008-0.800mg/L, Al
0.02 - 0.80 mg/l Al3+ (DR300)
 
1407099-CN DPD free chlorine powder pillows, 25mL, pk/100 Free chlorine Chlorine free 8021 DPD 0.02-2.00mg/L
Chlorine free and total 8210 0-3.00mg/L Cl₂
Chlorine free 10069 high range 0.1-10.0mg/L
Trihalomethane potential 10224 1190-1310mg/L as Cl₂
Chlorine demand 10223 varies by method
Chlorine free 10245 medium range 0.05-4.00mg/L
Chlorine free 10069, ultra-high range 0.0-10.0mg/L
Chlorine free 10245 0-4.00mg/L
DPD method (DR300)
100/pk 0.1-10.0mg/L, Cl2
0.05 - 4.00 mg/L or 0.1 - 10.0 mg/L Cl2 (DR300)
150
2608799-CN TPTZ iron reagent powder pillows, 10mL, pk/100 Iron Iron 8112 0.012-1.800mg/L
Iron 8112 0.01-1.70mg/L
Iron, total 8112 0-1.80mg/L
Iron 8112 0.04-1.80mg/L
TPTZ method (DR300)
100/pk 0.012-1.800mg/L, Fe
0.01 - 1.70 mg/l (DR300)
150
2516025-CN Ozone ACCUVAC, 0-0.25mg/L, pk/25 Ozone Ozone 8311 0.01-0.25mg/L O₃ low range
Ozone 8311 0-0.25mg/L
Ozone 8311 0-0.75mg/L
Ozone 8311 0-1.50mg/L
Indigo trisulfonate method (DR300)
25/pk 0.01-0.25mg/L, O3 150
2449400-CN Molybdate reagent kit Molybdenum, molybdate Molybdenum 8169 low range 0.02-3.00mg/LMo
Molybdenum, molybdate 8169 low range 0-3.00mg/L
Ternary complex method (DR300)
- 0.02-3.00mg/L, Mo
0.02 - 3.0 mg/l or 0.10 - 12.0 mg/l Mo (DR300)
150
2430000-CN Manganese reagent kit Manganese Manganese 8034 high range 0.1-20.0mg/L
Manganese 8034 high range 0-20.0mg/L
Periodate oxidation method (DR300)
- 0.1-20.0mg/L, Mn
0.2 - 20.0 mg/l (DR300)
150
2515025-CN Dissolved oxygen high range, ACCUVAC, pk/25 Dissolved oxygen Dissolved oxygen 8166 high range DO 0.3-15.0mg/L O₂
Dissolved oxygen 8333 ultra-high range 1.0-40.0mg/L O₂
Dissolved oxygen 8166 high range 0-15.0mg/L
Dissolved oxygen high range DO 0-15mg/L
HRDO method (DR300)
25/pk 0.3-15.0mg/L, O2
0.2 - 10.0 mg/l O2 (DR300)
150
2429300-CN Zinc reagent kit, 20mL Zinc Zinc 8009 0.01-2.00mg/L
Zinc 8009 0.01-3.00mg/L
Zinc 8009 0-3.00mg/L
Zinc 8009 0.02-3.00mg/L
Zinc reagent method (DR300)
- 0.01-3.00mg/L, Zn
0.02 - 3.0 mg/l Zn2+ (DR300)
150
2657512-CN Phenol red specification indicator, 50mL pH value pH 10076 6.5-8.5 pH
pH 10076 6.5-8.5 pH units
Phenol red (pH) (DR300)
50 6.5-8.5 pH 90

Accessories Information

  • LPV446.99.00012                          HACH communication adapter*

  • 5953100                                        Soft carrying case

  • 4674300                                        Alkaline batteries, AAA, 1.5V, 4 pcs

  • 2427606                                        Sample vials, 25X60 mm, 10 ml, with mark, 6 pcs

  • 4864302                                        Sample vials, with cap, 1cm/10ml, 2 pcs

  • 5262600                                        Sample vial caps, 1cm/10ml, 1 pc

  • 2401812                                        Sample vial caps, 1cm/10ml, 12 pcs

  • 2635300                                        SpecCheck secondary standard, gel, DPD chlorine, low range

  • 2980500                                        SpecCheck secondary standard, gel, DPD chlorine, medium range

  • 2893300                                        SpecCheck secondary standard, gel, DPD chlorine, high range

  • 2708000                                        SpecCheck secondary standard, gel, ozone, medium range, 0-0.75 mg/L

  • 2507500                                        SpecCheck secondary standard, gel, monochloramine and free ammonia

Ordering Guide

  • Order No.                                                                 Description

  • LPV445.80.00110                         DR300 - Portable colorimeter, free chlorine/total chlorine

  • LPV445.97.01110                         DR300 - Portable colorimeter, bromine

  • LPV445.97.02110                         DR300 - Portable colorimeter, nitrate

  • LPV445.97.03110                         DR300 - Portable colorimeter, dissolved oxygen

  • LPV445.97.04110                         DR300 - Portable colorimeter, ozone

  • LPV445.97.06110                         DR300 - Portable colorimeter, phosphate

  • LPV445.97.09110                         DR300 - Portable colorimeter, zinc

  • LPV445.97.10110                         DR300 - Portable colorimeter, molybdenum

  • LPV445.97.12110                         DR300 - Portable colorimeter, chlorine/pH

  • LPV445.97.15110                         DR300 - Portable colorimeter, manganese, HR

  • LPV445.97.16110                         DR300 - Portable colorimeter, iron (TPTZ method)

  • LPV445.97.22110                         DR300 - Portable colorimeter, iron (FerroVer method)

  • LPV445.97.25110                         DR300 - Portable colorimeter, aluminum

  • LPV445.97.26110                         DR300 - Portable colorimeter, monochloramine/free ammonia

  • LPV445.97.40110                         DR300 - Portable colorimeter, ammonia nitrogen

  • LPV445.80.51110                         DR300 - Portable colorimeter, chlorine dioxide

  • LPV445.97.62110                         DR300 - Portable colorimeter, free chlorine/total chlorine, MR

  • LPV445.97.50110                         DR300 - Portable colorimeter, 500 nm

  • LPV445.97.52110                         DR300 - Portable colorimeter, 528 nm

  • LPV445.97.60110                         DR300 - Portable colorimeter, 600 nm

  • LPV445.97.65110                         DR300 - Portable colorimeter, 655 nm

Source: Public information from the HACH Water Quality website

Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hach-lab — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hach-lab properly configured on the existing plant, with the aim of laboratory colorimetric and titrimetric water analysis.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hach-lab configuration has to involve selected by method standard, sample throughput and reagent kit.

Configuration

Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant selected by method standard, sample throughput and reagent kit, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is standardised methods that make data comparable between labs, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hach-lab — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was laboratory colorimetric and titrimetric water analysis.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by method standard, sample throughput and reagent kit.

What We Did

We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around selected by method standard, sample throughput and reagent kit, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — standardised methods that make data comparable between labs, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hach-lab — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hach-lab, focusing on laboratory colorimetric and titrimetric water analysis.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hach-lab specification must therefore cover selected by method standard, sample throughput and reagent kit.

Delivery Approach

Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on selected by method standard, sample throughput and reagent kit, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — standardised methods that make data comparable between labs, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hach-lab — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hach-lab; the focus is laboratory colorimetric and titrimetric water analysis.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by method standard, sample throughput and reagent kit.

Implementation

The scope ran through the laboratory line: configuring around lab method standards and sample throughput. Technically it hinges on selected by method standard, sample throughput and reagent kit, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means standardised methods that make data comparable between labs, which cut the workload on the site maintenance team.