Industries:
The DR300 portable colorimeter is suitable for water quality analysis and measurement in drinking water, wastewater, power, food and beverage, industrial and other industries.
Instrument Features:
-
The all-new upgraded DR300 portable colorimeter has been comprehensively improved based on the PCII colorimeter.
-
Direct-reading simple operation reduces operating errors and ensures accurate colorimeter measurement results.
-
The DR300 portable colorimeter is equipped with a large backlit display, rugged housing, and IP67-rated waterproof material, confidently handling various outdoor measurement environments.
-
Optional HACH communication adapter enables wireless connection to mobile phones and the Claros intelligent system, achieving wireless transmission and intelligent management of colorimeter measurement data.*
-
The DR300 portable colorimeter is suitable not only for field water quality measurement but also for laboratory water quality analysis.
Technical Specifications
-
Light source Light-emitting diode (LED)
-
Detector Silicon photodiode
-
Display LCD backlit display
-
Protection class IP67, waterproof at 1 m water depth for 30 minutes
-
Wavelength accuracy Fixed wavelength ±2 nm, varies by model
-
Spectral bandwidth 15 nm
-
Absorbance range 0 - 2.5 Abs
-
Operating environment 0 to 50 °C (32 to 122 °F), 0 to 90% relative humidity, non-condensing
-
Power supply 4 AAA batteries; approximately 5000 tests
-
Data storage Last 50 measurements
-
Sample cell 25 mm (10 mL), 1 cm (10 mL)
-
Weight 0.25 kg (0.55 lb)
-
Dimensions (W x L x H) 69mm x 157mm x 34mm
Related Reagents
| Order No. | Description | Parameter | Measuring method | Packaging | Measuring range | Warranty period (days) |
|---|---|---|---|---|---|---|
| 2105569-CN | DPD free chlorine reagent powder pillows, 10mL, pk/100 | Free chlorine, chlorine dioxide | Chlorine free 8021 DPD 0.02-2.00mg/L Chlorine demand 10223 varies by method Chlorine dioxide 10126 0.05-5.00mg/L ClO₂ Chlorine dioxide 10126 0.04-5.00mg/L ClO₂ Chlorine dioxide 10126 0-5.00mg/L Chlorine free 8021 DPD 0-2.00mg/L DPD method (DR300) |
100/pk | 0.02-2.00mg/L, Cl2 0.02 - 2.00 mg/l or 0.10 - 8.0 mg/l Cl2 (DR300) |
150 |
| 2770900-CN | CL02 DPD powder pillow/Glycine method reagent kit | Chlorine dioxide | Chlorine dioxide 10126 0.04-5.00mg/L ClO₂ Chlorine dioxide 10126 0.05-5.00mg/L ClO₂ Chlorine dioxide 10126 0-5.00mg/L DPD/Glycine method (DR300) |
- | 0.04-5.00mg/L, ClO2 0.05 - 5.00 mg/l ClO2 (DR300) |
150 |
| 2668000-CN | Ammonia nitrogen reagent kit | Ammonia | Ammonia 8155 0.01-0.50mg/L NH₃-N Ammonia 8155 0-0.50mg/L NH₃-N Ammonia 8155 0-1.00mg/L Salicylate method (DR300) |
- | 0.01-0.50mg/L, NH3-N 0.01 - 0.80 mg/L NH3-N (DR300) |
|
| 2105769-CN | FERROVER, iron reagent, pk/100 | Iron | Iron 8008 0.02-3.00mg/L Iron 8008 0.02-5.00mg/L Iron, total 8008 0-3.00mg/L Iron, total 10249 0-300.0mg/L Iron, total 10249 0.1-300.0mg/L FerroVer method (DR300) |
100/pk | 0.02-3.00mg/L, Fe 0.02 - 5.00 mg/l (DR300) |
150 |
| 2106169-CN | NITRAVER5 powder pillows, 10mL, pk/100 | Nitrate | Nitrate 8039 0.3-30.0mg/L NO₃ -N Nitrate 8171 0.1-10.0mg/L NO₃ -N Nitrate 8039 0.3-30.00mg/L NO₃ N Nitrate 8171 0.1-5.0mg/L Nitrate 8039 high range 0-30.0mg/L Nitrate 8171 medium range 0-5.0mg/L Nitrate 8171 0.2-5.0mg/L Cadmium reduction method (DR300) |
100/pk | 0.3-30.0mg/L, NO3-N 0.40 - 30.0 mg/l NO3-N (DR300) |
150 |
| 2106069-CN | PHOSVER3 powder pillows, 10mL, pk/100 | Reactive phosphorus | Phosphorus 8048 0.02-2.50mg/L PO₄ ³⁻ Phosphate 8007 1.0-125mg/L PO₄³- Phosphonate 8007 0.1-2.5mg/L Phosphonate 8007 0.02-2.50mg/L PO₄³- Phosphorus 8048 0-2.50mg/L Phosphonate 8007 0 -2.5 to 0-125mg/L PhosVer 3 (DR300) |
100/pk | 0.02-2.50mg/L, PO4 0.02 - 3.00 mg/l PO43- (DR300) |
150 |
| 2517025-CN | Ozone ACCUVAC, 0-0.75mg/L, pk/25 | Ozone | Ozone 8311 0.01-0.75mg/L O₃ medium range Ozone 8311 0-0.25mg/L Ozone 8311 0-0.75mg/L Ozone 8311 0-1.50mg/L Indigo trisulfonate method (DR300) |
25/pk | 0.01-0.75mg/L, O3 | 150 |
| 2242000-CN | Aluminum reagent kit | Aluminum | Aluminum 8012 0.008-0.800mg/L Aluminum 8012 0-0.80mg/L Aluminum 8012 0.01-0.80mg/L Aluminon method (DR300) |
- | 0.008-0.800mg/L, Al 0.02 - 0.80 mg/l Al3+ (DR300) |
|
| 1407099-CN | DPD free chlorine powder pillows, 25mL, pk/100 | Free chlorine | Chlorine free 8021 DPD 0.02-2.00mg/L Chlorine free and total 8210 0-3.00mg/L Cl₂ Chlorine free 10069 high range 0.1-10.0mg/L Trihalomethane potential 10224 1190-1310mg/L as Cl₂ Chlorine demand 10223 varies by method Chlorine free 10245 medium range 0.05-4.00mg/L Chlorine free 10069, ultra-high range 0.0-10.0mg/L Chlorine free 10245 0-4.00mg/L DPD method (DR300) |
100/pk | 0.1-10.0mg/L, Cl2 0.05 - 4.00 mg/L or 0.1 - 10.0 mg/L Cl2 (DR300) |
150 |
| 2608799-CN | TPTZ iron reagent powder pillows, 10mL, pk/100 | Iron | Iron 8112 0.012-1.800mg/L Iron 8112 0.01-1.70mg/L Iron, total 8112 0-1.80mg/L Iron 8112 0.04-1.80mg/L TPTZ method (DR300) |
100/pk | 0.012-1.800mg/L, Fe 0.01 - 1.70 mg/l (DR300) |
150 |
| 2516025-CN | Ozone ACCUVAC, 0-0.25mg/L, pk/25 | Ozone | Ozone 8311 0.01-0.25mg/L O₃ low range Ozone 8311 0-0.25mg/L Ozone 8311 0-0.75mg/L Ozone 8311 0-1.50mg/L Indigo trisulfonate method (DR300) |
25/pk | 0.01-0.25mg/L, O3 | 150 |
| 2449400-CN | Molybdate reagent kit | Molybdenum, molybdate | Molybdenum 8169 low range 0.02-3.00mg/LMo Molybdenum, molybdate 8169 low range 0-3.00mg/L Ternary complex method (DR300) |
- | 0.02-3.00mg/L, Mo 0.02 - 3.0 mg/l or 0.10 - 12.0 mg/l Mo (DR300) |
150 |
| 2430000-CN | Manganese reagent kit | Manganese | Manganese 8034 high range 0.1-20.0mg/L Manganese 8034 high range 0-20.0mg/L Periodate oxidation method (DR300) |
- | 0.1-20.0mg/L, Mn 0.2 - 20.0 mg/l (DR300) |
150 |
| 2515025-CN | Dissolved oxygen high range, ACCUVAC, pk/25 | Dissolved oxygen | Dissolved oxygen 8166 high range DO 0.3-15.0mg/L O₂ Dissolved oxygen 8333 ultra-high range 1.0-40.0mg/L O₂ Dissolved oxygen 8166 high range 0-15.0mg/L Dissolved oxygen high range DO 0-15mg/L HRDO method (DR300) |
25/pk | 0.3-15.0mg/L, O2 0.2 - 10.0 mg/l O2 (DR300) |
150 |
| 2429300-CN | Zinc reagent kit, 20mL | Zinc | Zinc 8009 0.01-2.00mg/L Zinc 8009 0.01-3.00mg/L Zinc 8009 0-3.00mg/L Zinc 8009 0.02-3.00mg/L Zinc reagent method (DR300) |
- | 0.01-3.00mg/L, Zn 0.02 - 3.0 mg/l Zn2+ (DR300) |
150 |
| 2657512-CN | Phenol red specification indicator, 50mL | pH value | pH 10076 6.5-8.5 pH pH 10076 6.5-8.5 pH units Phenol red (pH) (DR300) |
50 | 6.5-8.5 pH | 90 |
Accessories Information
-
LPV446.99.00012 HACH communication adapter*
-
5953100 Soft carrying case
-
4674300 Alkaline batteries, AAA, 1.5V, 4 pcs
-
2427606 Sample vials, 25X60 mm, 10 ml, with mark, 6 pcs
-
4864302 Sample vials, with cap, 1cm/10ml, 2 pcs
-
5262600 Sample vial caps, 1cm/10ml, 1 pc
-
2401812 Sample vial caps, 1cm/10ml, 12 pcs
-
2635300 SpecCheck secondary standard, gel, DPD chlorine, low range
-
2980500 SpecCheck secondary standard, gel, DPD chlorine, medium range
-
2893300 SpecCheck secondary standard, gel, DPD chlorine, high range
-
2708000 SpecCheck secondary standard, gel, ozone, medium range, 0-0.75 mg/L
-
2507500 SpecCheck secondary standard, gel, monochloramine and free ammonia
Ordering Guide
-
Order No. Description
-
LPV445.80.00110 DR300 - Portable colorimeter, free chlorine/total chlorine
-
LPV445.97.01110 DR300 - Portable colorimeter, bromine
-
LPV445.97.02110 DR300 - Portable colorimeter, nitrate
-
LPV445.97.03110 DR300 - Portable colorimeter, dissolved oxygen
-
LPV445.97.04110 DR300 - Portable colorimeter, ozone
-
LPV445.97.06110 DR300 - Portable colorimeter, phosphate
-
LPV445.97.09110 DR300 - Portable colorimeter, zinc
-
LPV445.97.10110 DR300 - Portable colorimeter, molybdenum
-
LPV445.97.12110 DR300 - Portable colorimeter, chlorine/pH
-
LPV445.97.15110 DR300 - Portable colorimeter, manganese, HR
-
LPV445.97.16110 DR300 - Portable colorimeter, iron (TPTZ method)
-
LPV445.97.22110 DR300 - Portable colorimeter, iron (FerroVer method)
-
LPV445.97.25110 DR300 - Portable colorimeter, aluminum
-
LPV445.97.26110 DR300 - Portable colorimeter, monochloramine/free ammonia
-
LPV445.97.40110 DR300 - Portable colorimeter, ammonia nitrogen
-
LPV445.80.51110 DR300 - Portable colorimeter, chlorine dioxide
-
LPV445.97.62110 DR300 - Portable colorimeter, free chlorine/total chlorine, MR
-
LPV445.97.50110 DR300 - Portable colorimeter, 500 nm
-
LPV445.97.52110 DR300 - Portable colorimeter, 528 nm
-
LPV445.97.60110 DR300 - Portable colorimeter, 600 nm
-
LPV445.97.65110 DR300 - Portable colorimeter, 655 nm
Source: Public information from the HACH Water Quality website
Case Studies
Municipal Wastewater Treatment · Hach-lab — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hach-lab properly configured on the existing plant, with the aim of laboratory colorimetric and titrimetric water analysis.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hach-lab configuration has to involve selected by method standard, sample throughput and reagent kit.
Configuration
Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant selected by method standard, sample throughput and reagent kit, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is standardised methods that make data comparable between labs, and the readings are now used for process tuning.
Food & Beverage · Hach-lab — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was laboratory colorimetric and titrimetric water analysis.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by method standard, sample throughput and reagent kit.
What We Did
We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around selected by method standard, sample throughput and reagent kit, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — standardised methods that make data comparable between labs, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Hach-lab — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hach-lab, focusing on laboratory colorimetric and titrimetric water analysis.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hach-lab specification must therefore cover selected by method standard, sample throughput and reagent kit.
Delivery Approach
Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on selected by method standard, sample throughput and reagent kit, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — standardised methods that make data comparable between labs, with confidence in this measuring point improving markedly.
Power & Energy · Hach-lab — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hach-lab; the focus is laboratory colorimetric and titrimetric water analysis.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by method standard, sample throughput and reagent kit.
Implementation
The scope ran through the laboratory line: configuring around lab method standards and sample throughput. Technically it hinges on selected by method standard, sample throughput and reagent kit, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means standardised methods that make data comparable between labs, which cut the workload on the site maintenance team.
Related Products
HACHDigester (rapid COD digester)
HACHWater quality analysis test strip series
HACHMulti-channel electrochemical analyzer
HACHPro/Pro+ pocket water tester
HACHLiquid colorimeter
HACHPortable water toxicity analyzer
HACH1000 series automatic potentiometric titrator
HACH