Industries:
The DR300 portable colorimeter is suitable for water quality analysis and measurement in drinking water, wastewater, power, food and beverage, industrial and other industries.
Instrument Features:
-
The all-new upgraded DR300 portable colorimeter has been comprehensively improved based on the PCII colorimeter.
-
Direct-reading simple operation reduces operating errors and ensures accurate colorimeter measurement results.
-
The DR300 portable colorimeter is equipped with a large backlit display, rugged housing, and IP67-rated waterproof material, confidently handling various outdoor measurement environments.
-
Optional HACH communication adapter enables wireless connection to mobile phones and the Claros intelligent system, achieving wireless transmission and intelligent management of colorimeter measurement data.*
-
The DR300 portable colorimeter is suitable not only for field water quality measurement but also for laboratory water quality analysis.
Technical Specifications
-
Light source Light-emitting diode (LED)
-
Detector Silicon photodiode
-
Display LCD backlit display
-
Protection class IP67, waterproof at 1 m water depth for 30 minutes
-
Wavelength accuracy Fixed wavelength ±2 nm, varies by model
-
Spectral bandwidth 15 nm
-
Absorbance range 0 - 2.5 Abs
-
Operating environment 0 to 50 °C (32 to 122 °F), 0 to 90% relative humidity, non-condensing
-
Power supply 4 AAA batteries; approximately 5000 tests
-
Data storage Last 50 measurements
-
Sample cell 25 mm (10 mL), 1 cm (10 mL)
-
Weight 0.25 kg (0.55 lb)
-
Dimensions (W x L x H) 69mm x 157mm x 34mm
Related Reagents
| Order No. | Description | Parameter | Measuring method | Packaging | Measuring range | Warranty period (days) |
|---|---|---|---|---|---|---|
| 2105569-CN | DPD free chlorine reagent powder pillows, 10mL, pk/100 | Free chlorine, chlorine dioxide | Chlorine free 8021 DPD 0.02-2.00mg/L Chlorine demand 10223 varies by method Chlorine dioxide 10126 0.05-5.00mg/L ClO₂ Chlorine dioxide 10126 0.04-5.00mg/L ClO₂ Chlorine dioxide 10126 0-5.00mg/L Chlorine free 8021 DPD 0-2.00mg/L DPD method (DR300) |
100/pk | 0.02-2.00mg/L, Cl2 0.02 - 2.00 mg/l or 0.10 - 8.0 mg/l Cl2 (DR300) |
150 |
| 2770900-CN | CL02 DPD powder pillow/Glycine method reagent kit | Chlorine dioxide | Chlorine dioxide 10126 0.04-5.00mg/L ClO₂ Chlorine dioxide 10126 0.05-5.00mg/L ClO₂ Chlorine dioxide 10126 0-5.00mg/L DPD/Glycine method (DR300) |
- | 0.04-5.00mg/L, ClO2 0.05 - 5.00 mg/l ClO2 (DR300) |
150 |
| 2668000-CN | Ammonia nitrogen reagent kit | Ammonia | Ammonia 8155 0.01-0.50mg/L NH₃-N Ammonia 8155 0-0.50mg/L NH₃-N Ammonia 8155 0-1.00mg/L Salicylate method (DR300) |
- | 0.01-0.50mg/L, NH3-N 0.01 - 0.80 mg/L NH3-N (DR300) |
|
| 2105769-CN | FERROVER, iron reagent, pk/100 | Iron | Iron 8008 0.02-3.00mg/L Iron 8008 0.02-5.00mg/L Iron, total 8008 0-3.00mg/L Iron, total 10249 0-300.0mg/L Iron, total 10249 0.1-300.0mg/L FerroVer method (DR300) |
100/pk | 0.02-3.00mg/L, Fe 0.02 - 5.00 mg/l (DR300) |
150 |
| 2106169-CN | NITRAVER5 powder pillows, 10mL, pk/100 | Nitrate | Nitrate 8039 0.3-30.0mg/L NO₃ -N Nitrate 8171 0.1-10.0mg/L NO₃ -N Nitrate 8039 0.3-30.00mg/L NO₃ N Nitrate 8171 0.1-5.0mg/L Nitrate 8039 high range 0-30.0mg/L Nitrate 8171 medium range 0-5.0mg/L Nitrate 8171 0.2-5.0mg/L Cadmium reduction method (DR300) |
100/pk | 0.3-30.0mg/L, NO3-N 0.40 - 30.0 mg/l NO3-N (DR300) |
150 |
| 2106069-CN | PHOSVER3 powder pillows, 10mL, pk/100 | Reactive phosphorus | Phosphorus 8048 0.02-2.50mg/L PO₄ ³⁻ Phosphate 8007 1.0-125mg/L PO₄³- Phosphonate 8007 0.1-2.5mg/L Phosphonate 8007 0.02-2.50mg/L PO₄³- Phosphorus 8048 0-2.50mg/L Phosphonate 8007 0 -2.5 to 0-125mg/L PhosVer 3 (DR300) |
100/pk | 0.02-2.50mg/L, PO4 0.02 - 3.00 mg/l PO43- (DR300) |
150 |
| 2517025-CN | Ozone ACCUVAC, 0-0.75mg/L, pk/25 | Ozone | Ozone 8311 0.01-0.75mg/L O₃ medium range Ozone 8311 0-0.25mg/L Ozone 8311 0-0.75mg/L Ozone 8311 0-1.50mg/L Indigo trisulfonate method (DR300) |
25/pk | 0.01-0.75mg/L, O3 | 150 |
| 2242000-CN | Aluminum reagent kit | Aluminum | Aluminum 8012 0.008-0.800mg/L Aluminum 8012 0-0.80mg/L Aluminum 8012 0.01-0.80mg/L Aluminon method (DR300) |
- | 0.008-0.800mg/L, Al 0.02 - 0.80 mg/l Al3+ (DR300) |
|
| 1407099-CN | DPD free chlorine powder pillows, 25mL, pk/100 | Free chlorine | Chlorine free 8021 DPD 0.02-2.00mg/L Chlorine free and total 8210 0-3.00mg/L Cl₂ Chlorine free 10069 high range 0.1-10.0mg/L Trihalomethane potential 10224 1190-1310mg/L as Cl₂ Chlorine demand 10223 varies by method Chlorine free 10245 medium range 0.05-4.00mg/L Chlorine free 10069, ultra-high range 0.0-10.0mg/L Chlorine free 10245 0-4.00mg/L DPD method (DR300) |
100/pk | 0.1-10.0mg/L, Cl2 0.05 - 4.00 mg/L or 0.1 - 10.0 mg/L Cl2 (DR300) |
150 |
| 2608799-CN | TPTZ iron reagent powder pillows, 10mL, pk/100 | Iron | Iron 8112 0.012-1.800mg/L Iron 8112 0.01-1.70mg/L Iron, total 8112 0-1.80mg/L Iron 8112 0.04-1.80mg/L TPTZ method (DR300) |
100/pk | 0.012-1.800mg/L, Fe 0.01 - 1.70 mg/l (DR300) |
150 |
| 2516025-CN | Ozone ACCUVAC, 0-0.25mg/L, pk/25 | Ozone | Ozone 8311 0.01-0.25mg/L O₃ low range Ozone 8311 0-0.25mg/L Ozone 8311 0-0.75mg/L Ozone 8311 0-1.50mg/L Indigo trisulfonate method (DR300) |
25/pk | 0.01-0.25mg/L, O3 | 150 |
| 2449400-CN | Molybdate reagent kit | Molybdenum, molybdate | Molybdenum 8169 low range 0.02-3.00mg/LMo Molybdenum, molybdate 8169 low range 0-3.00mg/L Ternary complex method (DR300) |
- | 0.02-3.00mg/L, Mo 0.02 - 3.0 mg/l or 0.10 - 12.0 mg/l Mo (DR300) |
150 |
| 2430000-CN | Manganese reagent kit | Manganese | Manganese 8034 high range 0.1-20.0mg/L Manganese 8034 high range 0-20.0mg/L Periodate oxidation method (DR300) |
- | 0.1-20.0mg/L, Mn 0.2 - 20.0 mg/l (DR300) |
150 |
| 2515025-CN | Dissolved oxygen high range, ACCUVAC, pk/25 | Dissolved oxygen | Dissolved oxygen 8166 high range DO 0.3-15.0mg/L O₂ Dissolved oxygen 8333 ultra-high range 1.0-40.0mg/L O₂ Dissolved oxygen 8166 high range 0-15.0mg/L Dissolved oxygen high range DO 0-15mg/L HRDO method (DR300) |
25/pk | 0.3-15.0mg/L, O2 0.2 - 10.0 mg/l O2 (DR300) |
150 |
| 2429300-CN | Zinc reagent kit, 20mL | Zinc | Zinc 8009 0.01-2.00mg/L Zinc 8009 0.01-3.00mg/L Zinc 8009 0-3.00mg/L Zinc 8009 0.02-3.00mg/L Zinc reagent method (DR300) |
- | 0.01-3.00mg/L, Zn 0.02 - 3.0 mg/l Zn2+ (DR300) |
150 |
| 2657512-CN | Phenol red specification indicator, 50mL | pH value | pH 10076 6.5-8.5 pH pH 10076 6.5-8.5 pH units Phenol red (pH) (DR300) |
50 | 6.5-8.5 pH | 90 |
Accessories Information
-
LPV446.99.00012 HACH communication adapter*
-
5953100 Soft carrying case
-
4674300 Alkaline batteries, AAA, 1.5V, 4 pcs
-
2427606 Sample vials, 25X60 mm, 10 ml, with mark, 6 pcs
-
4864302 Sample vials, with cap, 1cm/10ml, 2 pcs
-
5262600 Sample vial caps, 1cm/10ml, 1 pc
-
2401812 Sample vial caps, 1cm/10ml, 12 pcs
-
2635300 SpecCheck secondary standard, gel, DPD chlorine, low range
-
2980500 SpecCheck secondary standard, gel, DPD chlorine, medium range
-
2893300 SpecCheck secondary standard, gel, DPD chlorine, high range
-
2708000 SpecCheck secondary standard, gel, ozone, medium range, 0-0.75 mg/L
-
2507500 SpecCheck secondary standard, gel, monochloramine and free ammonia
Ordering Guide
-
Order No. Description
-
LPV445.80.00110 DR300 - Portable colorimeter, free chlorine/total chlorine
-
LPV445.97.01110 DR300 - Portable colorimeter, bromine
-
LPV445.97.02110 DR300 - Portable colorimeter, nitrate
-
LPV445.97.03110 DR300 - Portable colorimeter, dissolved oxygen
-
LPV445.97.04110 DR300 - Portable colorimeter, ozone
-
LPV445.97.06110 DR300 - Portable colorimeter, phosphate
-
LPV445.97.09110 DR300 - Portable colorimeter, zinc
-
LPV445.97.10110 DR300 - Portable colorimeter, molybdenum
-
LPV445.97.12110 DR300 - Portable colorimeter, chlorine/pH
-
LPV445.97.15110 DR300 - Portable colorimeter, manganese, HR
-
LPV445.97.16110 DR300 - Portable colorimeter, iron (TPTZ method)
-
LPV445.97.22110 DR300 - Portable colorimeter, iron (FerroVer method)
-
LPV445.97.25110 DR300 - Portable colorimeter, aluminum
-
LPV445.97.26110 DR300 - Portable colorimeter, monochloramine/free ammonia
-
LPV445.97.40110 DR300 - Portable colorimeter, ammonia nitrogen
-
LPV445.80.51110 DR300 - Portable colorimeter, chlorine dioxide
-
LPV445.97.62110 DR300 - Portable colorimeter, free chlorine/total chlorine, MR
-
LPV445.97.50110 DR300 - Portable colorimeter, 500 nm
-
LPV445.97.52110 DR300 - Portable colorimeter, 528 nm
-
LPV445.97.60110 DR300 - Portable colorimeter, 600 nm
-
LPV445.97.65110 DR300 - Portable colorimeter, 655 nm
Source: Public information from the HACH Water Quality website
Casos de servicio
Tratamiento de Aguas Residuales Municipales — Hach-Lab: caso de aplicación
Resumen del proyecto
La instalación está en las etapas de entrada, biológica y salida de una planta municipal. El cliente quería configurar bien Hach-Lab en la planta existente, con el objetivo de análisis de agua colorimétrico y volumétrico en laboratorio.
Retos técnicos
Lo que realmente da problemas es alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal, y los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Todo ello implica que la configuración de Hach-Lab deba incluir selección por método, volumen de muestras y kit de reactivos.
Configuración
El suministro y la instalación se organizaron por la vía de laboratorio: configurar según métodos de laboratorio y volumen de muestras. En planta esto supuso selección por método, volumen de muestras y kit de reactivos; se revisó línea a línea: cumplimiento estable del nivel 1A y reporte de datos en línea.
Comportamiento
Tras la puesta en marcha el resultado es métodos normalizados que hacen comparables los datos entre laboratorios, y las lecturas se usan ya para ajustar el proceso.
Alimentación y Bebidas — Hach-Lab: caso de aplicación
Situación en planta
Se trata de un cliente del sector Alimentación y Bebidas cuya planta está en las etapas de dosificación, pasteurización, llenado y limpieza CIP. La tarea principal era análisis de agua colorimétrico y volumétrico en laboratorio.
El problema
La dificultad está en jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos; a la vez, las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente. Por eso la especificación implica selección por método, volumen de muestras y kit de reactivos.
Qué hicimos
Adoptamos un enfoque de laboratorio: configurar según métodos de laboratorio y volumen de muestras. La entrega se construyó en torno a selección por método, volumen de muestras y kit de reactivos; se verificó punto por punto: requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.
Resultado operativo
En servicio el sistema responde a lo previsto: métodos normalizados que hacen comparables los datos entre laboratorios, con un mantenimiento rutinario notablemente menor.
Química y Farmacéutica — Hach-Lab: caso de aplicación
Contexto de aplicación
reactores, vasijas de dosificación y tanques de producto terminado es un servicio típico de Química y Farmacéutica. El proyecto partió de Hach-Lab, centrándose en análisis de agua colorimétrico y volumétrico en laboratorio.
Limitaciones del proceso
la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, y medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas no hace sino acentuarlo. Por eso la especificación de Hach-Lab debe cubrir selección por método, volumen de muestras y kit de reactivos.
Enfoque de suministro
La entrega se gestionó como laboratorio: configurar según métodos de laboratorio y volumen de muestras. La ejecución se centró en selección por método, volumen de muestras y kit de reactivos, junto con certificación Ex y trazabilidad de datos según GMP.
Resultados en campo
La operación evidencia el beneficio: métodos normalizados que hacen comparables los datos entre laboratorios, con una confianza claramente mayor en este punto de medición.
Energía y Electricidad — Hach-Lab: caso de aplicación
Perfil del cliente
El entorno típico en Energía y Electricidad es agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El punto de medición es Hach-Lab; el foco es análisis de agua colorimétrico y volumétrico en laboratorio.
Dificultades clave
Las condiciones son alta temperatura y presión, con vapor y agua salina y, encima, deriva a alta temperatura y presión, con paradas no programadas muy costosas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de selección por método, volumen de muestras y kit de reactivos.
Implementación
El alcance se canalizó por la vía de laboratorio: configurar según métodos de laboratorio y volumen de muestras. Técnicamente se apoya en selección por método, volumen de muestras y kit de reactivos, y en estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.
Beneficio para el cliente
En la práctica esto significa métodos normalizados que hacen comparables los datos entre laboratorios, lo que redujo la carga del equipo de mantenimiento.
Recomendados similares
HACHDigestor (digestor rápido de COD)
HACHSerie de tiras reactivas para análisis de agua
HACHAnalizador electroquímico multicanal
HACHMedidor de bolsillo de agua Pro/Pro+
HACHColorímetro de líquidos
HACHAnalizador portátil de toxicidad del agua
HACHValorador potenciométrico automático serie 1000
HACH