Instrumentación · Ingeniería · Paquete · PLC
0755-82221901 sales@ainstru.com

DR300 Colorímetro portátil

DR300 Colorímetro portátil
Colorímetro portátil
HACH DR300
El colorímetro portátil DR300 es una mejora integral respecto al colorímetro PCII: funcionamiento de lectura directa, pantalla más grande, retroiluminación más brillante y grado de protección IP67. Es un colorímetro portátil de un solo parámetro apto para mediciones de calidad del agua en laboratorio y campo.

Industries:

The DR300 portable colorimeter is suitable for water quality analysis and measurement in drinking water, wastewater, power, food and beverage, industrial and other industries.

Instrument Features:

  • The all-new upgraded DR300 portable colorimeter has been comprehensively improved based on the PCII colorimeter.

  • Direct-reading simple operation reduces operating errors and ensures accurate colorimeter measurement results.

  • The DR300 portable colorimeter is equipped with a large backlit display, rugged housing, and IP67-rated waterproof material, confidently handling various outdoor measurement environments.

  • Optional HACH communication adapter enables wireless connection to mobile phones and the Claros intelligent system, achieving wireless transmission and intelligent management of colorimeter measurement data.*

  • The DR300 portable colorimeter is suitable not only for field water quality measurement but also for laboratory water quality analysis.

Technical Specifications

  • Light source    Light-emitting diode (LED)

  • Detector    Silicon photodiode

  • Display    LCD backlit display

  • Protection class    IP67, waterproof at 1 m water depth for 30 minutes

  • Wavelength accuracy    Fixed wavelength ±2 nm, varies by model

  • Spectral bandwidth    15 nm

  • Absorbance range    0 - 2.5 Abs

  • Operating environment    0 to 50 °C (32 to 122 °F), 0 to 90% relative humidity, non-condensing

  • Power supply    4 AAA batteries; approximately 5000 tests

  • Data storage    Last 50 measurements

  • Sample cell    25 mm (10 mL), 1 cm (10 mL)

  • Weight    0.25 kg (0.55 lb)

  • Dimensions (W x L x H)    69mm x 157mm x 34mm

Related Reagents

Order No. Description Parameter Measuring method Packaging Measuring range Warranty period (days)
2105569-CN DPD free chlorine reagent powder pillows, 10mL, pk/100 Free chlorine, chlorine dioxide Chlorine free 8021 DPD 0.02-2.00mg/L
Chlorine demand 10223 varies by method
Chlorine dioxide 10126 0.05-5.00mg/L ClO₂
Chlorine dioxide 10126 0.04-5.00mg/L ClO₂
Chlorine dioxide 10126 0-5.00mg/L
Chlorine free 8021 DPD 0-2.00mg/L
DPD method (DR300)
100/pk 0.02-2.00mg/L, Cl2
0.02 - 2.00 mg/l or 0.10 - 8.0 mg/l Cl2 (DR300)
150
2770900-CN CL02 DPD powder pillow/Glycine method reagent kit Chlorine dioxide Chlorine dioxide 10126 0.04-5.00mg/L ClO₂
Chlorine dioxide 10126 0.05-5.00mg/L ClO₂
Chlorine dioxide 10126 0-5.00mg/L
DPD/Glycine method (DR300)
- 0.04-5.00mg/L, ClO2
0.05 - 5.00 mg/l ClO2 (DR300)
150
2668000-CN Ammonia nitrogen reagent kit Ammonia Ammonia 8155 0.01-0.50mg/L NH₃-N
Ammonia 8155 0-0.50mg/L NH₃-N
Ammonia 8155 0-1.00mg/L
Salicylate method (DR300)
- 0.01-0.50mg/L, NH3-N
0.01 - 0.80 mg/L NH3-N (DR300)
 
2105769-CN FERROVER, iron reagent, pk/100 Iron Iron 8008 0.02-3.00mg/L
Iron 8008 0.02-5.00mg/L
Iron, total 8008 0-3.00mg/L
Iron, total 10249 0-300.0mg/L
Iron, total 10249 0.1-300.0mg/L
FerroVer method (DR300)
100/pk 0.02-3.00mg/L, Fe
0.02 - 5.00 mg/l (DR300)
150
2106169-CN NITRAVER5 powder pillows, 10mL, pk/100 Nitrate Nitrate 8039 0.3-30.0mg/L NO₃ -N
Nitrate 8171 0.1-10.0mg/L NO₃ -N
Nitrate 8039 0.3-30.00mg/L NO₃ ­N
Nitrate 8171 0.1-5.0mg/L
Nitrate 8039 high range 0-30.0mg/L
Nitrate 8171 medium range 0-5.0mg/L
Nitrate 8171 0.2-5.0mg/L
Cadmium reduction method (DR300)
100/pk 0.3-30.0mg/L, NO3-N
0.40 - 30.0 mg/l NO3-N (DR300)
150
2106069-CN PHOSVER3 powder pillows, 10mL, pk/100 Reactive phosphorus Phosphorus 8048 0.02-2.50mg/L PO₄ ³⁻
Phosphate 8007 1.0-125mg/L PO₄³-
Phosphonate 8007 0.1-2.5mg/L
Phosphonate 8007 0.02-2.50mg/L PO₄³-
Phosphorus 8048 0-2.50mg/L
Phosphonate 8007 0 -2.5 to 0-125mg/L
PhosVer 3 (DR300)
100/pk 0.02-2.50mg/L, PO4
0.02 - 3.00 mg/l PO43- (DR300)
150
2517025-CN Ozone ACCUVAC, 0-0.75mg/L, pk/25 Ozone Ozone 8311 0.01-0.75mg/L O₃ medium range
Ozone 8311 0-0.25mg/L
Ozone 8311 0-0.75mg/L
Ozone 8311 0-1.50mg/L
Indigo trisulfonate method (DR300)
25/pk 0.01-0.75mg/L, O3 150
2242000-CN Aluminum reagent kit Aluminum Aluminum 8012 0.008-0.800mg/L
Aluminum 8012 0-0.80mg/L
Aluminum 8012 0.01-0.80mg/L
Aluminon method (DR300)
- 0.008-0.800mg/L, Al
0.02 - 0.80 mg/l Al3+ (DR300)
 
1407099-CN DPD free chlorine powder pillows, 25mL, pk/100 Free chlorine Chlorine free 8021 DPD 0.02-2.00mg/L
Chlorine free and total 8210 0-3.00mg/L Cl₂
Chlorine free 10069 high range 0.1-10.0mg/L
Trihalomethane potential 10224 1190-1310mg/L as Cl₂
Chlorine demand 10223 varies by method
Chlorine free 10245 medium range 0.05-4.00mg/L
Chlorine free 10069, ultra-high range 0.0-10.0mg/L
Chlorine free 10245 0-4.00mg/L
DPD method (DR300)
100/pk 0.1-10.0mg/L, Cl2
0.05 - 4.00 mg/L or 0.1 - 10.0 mg/L Cl2 (DR300)
150
2608799-CN TPTZ iron reagent powder pillows, 10mL, pk/100 Iron Iron 8112 0.012-1.800mg/L
Iron 8112 0.01-1.70mg/L
Iron, total 8112 0-1.80mg/L
Iron 8112 0.04-1.80mg/L
TPTZ method (DR300)
100/pk 0.012-1.800mg/L, Fe
0.01 - 1.70 mg/l (DR300)
150
2516025-CN Ozone ACCUVAC, 0-0.25mg/L, pk/25 Ozone Ozone 8311 0.01-0.25mg/L O₃ low range
Ozone 8311 0-0.25mg/L
Ozone 8311 0-0.75mg/L
Ozone 8311 0-1.50mg/L
Indigo trisulfonate method (DR300)
25/pk 0.01-0.25mg/L, O3 150
2449400-CN Molybdate reagent kit Molybdenum, molybdate Molybdenum 8169 low range 0.02-3.00mg/LMo
Molybdenum, molybdate 8169 low range 0-3.00mg/L
Ternary complex method (DR300)
- 0.02-3.00mg/L, Mo
0.02 - 3.0 mg/l or 0.10 - 12.0 mg/l Mo (DR300)
150
2430000-CN Manganese reagent kit Manganese Manganese 8034 high range 0.1-20.0mg/L
Manganese 8034 high range 0-20.0mg/L
Periodate oxidation method (DR300)
- 0.1-20.0mg/L, Mn
0.2 - 20.0 mg/l (DR300)
150
2515025-CN Dissolved oxygen high range, ACCUVAC, pk/25 Dissolved oxygen Dissolved oxygen 8166 high range DO 0.3-15.0mg/L O₂
Dissolved oxygen 8333 ultra-high range 1.0-40.0mg/L O₂
Dissolved oxygen 8166 high range 0-15.0mg/L
Dissolved oxygen high range DO 0-15mg/L
HRDO method (DR300)
25/pk 0.3-15.0mg/L, O2
0.2 - 10.0 mg/l O2 (DR300)
150
2429300-CN Zinc reagent kit, 20mL Zinc Zinc 8009 0.01-2.00mg/L
Zinc 8009 0.01-3.00mg/L
Zinc 8009 0-3.00mg/L
Zinc 8009 0.02-3.00mg/L
Zinc reagent method (DR300)
- 0.01-3.00mg/L, Zn
0.02 - 3.0 mg/l Zn2+ (DR300)
150
2657512-CN Phenol red specification indicator, 50mL pH value pH 10076 6.5-8.5 pH
pH 10076 6.5-8.5 pH units
Phenol red (pH) (DR300)
50 6.5-8.5 pH 90

Accessories Information

  • LPV446.99.00012                          HACH communication adapter*

  • 5953100                                        Soft carrying case

  • 4674300                                        Alkaline batteries, AAA, 1.5V, 4 pcs

  • 2427606                                        Sample vials, 25X60 mm, 10 ml, with mark, 6 pcs

  • 4864302                                        Sample vials, with cap, 1cm/10ml, 2 pcs

  • 5262600                                        Sample vial caps, 1cm/10ml, 1 pc

  • 2401812                                        Sample vial caps, 1cm/10ml, 12 pcs

  • 2635300                                        SpecCheck secondary standard, gel, DPD chlorine, low range

  • 2980500                                        SpecCheck secondary standard, gel, DPD chlorine, medium range

  • 2893300                                        SpecCheck secondary standard, gel, DPD chlorine, high range

  • 2708000                                        SpecCheck secondary standard, gel, ozone, medium range, 0-0.75 mg/L

  • 2507500                                        SpecCheck secondary standard, gel, monochloramine and free ammonia

Ordering Guide

  • Order No.                                                                 Description

  • LPV445.80.00110                         DR300 - Portable colorimeter, free chlorine/total chlorine

  • LPV445.97.01110                         DR300 - Portable colorimeter, bromine

  • LPV445.97.02110                         DR300 - Portable colorimeter, nitrate

  • LPV445.97.03110                         DR300 - Portable colorimeter, dissolved oxygen

  • LPV445.97.04110                         DR300 - Portable colorimeter, ozone

  • LPV445.97.06110                         DR300 - Portable colorimeter, phosphate

  • LPV445.97.09110                         DR300 - Portable colorimeter, zinc

  • LPV445.97.10110                         DR300 - Portable colorimeter, molybdenum

  • LPV445.97.12110                         DR300 - Portable colorimeter, chlorine/pH

  • LPV445.97.15110                         DR300 - Portable colorimeter, manganese, HR

  • LPV445.97.16110                         DR300 - Portable colorimeter, iron (TPTZ method)

  • LPV445.97.22110                         DR300 - Portable colorimeter, iron (FerroVer method)

  • LPV445.97.25110                         DR300 - Portable colorimeter, aluminum

  • LPV445.97.26110                         DR300 - Portable colorimeter, monochloramine/free ammonia

  • LPV445.97.40110                         DR300 - Portable colorimeter, ammonia nitrogen

  • LPV445.80.51110                         DR300 - Portable colorimeter, chlorine dioxide

  • LPV445.97.62110                         DR300 - Portable colorimeter, free chlorine/total chlorine, MR

  • LPV445.97.50110                         DR300 - Portable colorimeter, 500 nm

  • LPV445.97.52110                         DR300 - Portable colorimeter, 528 nm

  • LPV445.97.60110                         DR300 - Portable colorimeter, 600 nm

  • LPV445.97.65110                         DR300 - Portable colorimeter, 655 nm

Source: Public information from the HACH Water Quality website

Tratamiento de Aguas Residuales Municipales

Tratamiento de Aguas Residuales Municipales — Hach-Lab: caso de aplicación

Resumen del proyecto

La instalación está en las etapas de entrada, biológica y salida de una planta municipal. El cliente quería configurar bien Hach-Lab en la planta existente, con el objetivo de análisis de agua colorimétrico y volumétrico en laboratorio.

Retos técnicos

Lo que realmente da problemas es alto contenido de sólidos y componentes corrosivos, con grandes variaciones diarias de caudal, y los parámetros del efluente oscilan y las sondas se ensucian con lodos y biopelícula. Todo ello implica que la configuración de Hach-Lab deba incluir selección por método, volumen de muestras y kit de reactivos.

Configuración

El suministro y la instalación se organizaron por la vía de laboratorio: configurar según métodos de laboratorio y volumen de muestras. En planta esto supuso selección por método, volumen de muestras y kit de reactivos; se revisó línea a línea: cumplimiento estable del nivel 1A y reporte de datos en línea.

Comportamiento

Tras la puesta en marcha el resultado es métodos normalizados que hacen comparables los datos entre laboratorios, y las lecturas se usan ya para ajustar el proceso.

Alimentación y Bebidas

Alimentación y Bebidas — Hach-Lab: caso de aplicación

Situación en planta

Se trata de un cliente del sector Alimentación y Bebidas cuya planta está en las etapas de dosificación, pasteurización, llenado y limpieza CIP. La tarea principal era análisis de agua colorimétrico y volumétrico en laboratorio.

El problema

La dificultad está en jarabes, lácteos y bebidas proclives a incrustaciones, con estrictos requisitos higiénicos; a la vez, las limpiezas frecuentes exigen instrumentos resistentes a ciclos CIP/SIP con sosa caliente. Por eso la especificación implica selección por método, volumen de muestras y kit de reactivos.

Qué hicimos

Adoptamos un enfoque de laboratorio: configurar según métodos de laboratorio y volumen de muestras. La entrega se construyó en torno a selección por método, volumen de muestras y kit de reactivos; se verificó punto por punto: requisitos de seguridad alimentaria y diseño higiénico 3-A / EHEDG.

Resultado operativo

En servicio el sistema responde a lo previsto: métodos normalizados que hacen comparables los datos entre laboratorios, con un mantenimiento rutinario notablemente menor.

Química y Farmacéutica

Química y Farmacéutica — Hach-Lab: caso de aplicación

Contexto de aplicación

reactores, vasijas de dosificación y tanques de producto terminado es un servicio típico de Química y Farmacéutica. El proyecto partió de Hach-Lab, centrándose en análisis de agua colorimétrico y volumétrico en laboratorio.

Limitaciones del proceso

la corrosión y la protección Ex acortan la vida útil y encarecen las paradas, y medios muy corrosivos con disolventes y cristalización, en parte en atmósferas explosivas no hace sino acentuarlo. Por eso la especificación de Hach-Lab debe cubrir selección por método, volumen de muestras y kit de reactivos.

Enfoque de suministro

La entrega se gestionó como laboratorio: configurar según métodos de laboratorio y volumen de muestras. La ejecución se centró en selección por método, volumen de muestras y kit de reactivos, junto con certificación Ex y trazabilidad de datos según GMP.

Resultados en campo

La operación evidencia el beneficio: métodos normalizados que hacen comparables los datos entre laboratorios, con una confianza claramente mayor en este punto de medición.

Energía y Electricidad

Energía y Electricidad — Hach-Lab: caso de aplicación

Perfil del cliente

El entorno típico en Energía y Electricidad es agua de alimentación, condensado de turbina y sistemas de desulfuración/DeNOx. El punto de medición es Hach-Lab; el foco es análisis de agua colorimétrico y volumétrico en laboratorio.

Dificultades clave

Las condiciones son alta temperatura y presión, con vapor y agua salina y, encima, deriva a alta temperatura y presión, con paradas no programadas muy costosas, algo que una configuración estándar no soporta mucho tiempo. El diseño parte de selección por método, volumen de muestras y kit de reactivos.

Implementación

El alcance se canalizó por la vía de laboratorio: configurar según métodos de laboratorio y volumen de muestras. Técnicamente se apoya en selección por método, volumen de muestras y kit de reactivos, y en estos requisitos: cumplimiento de normativas del sector y objetivos de disponibilidad.

Beneficio para el cliente

En la práctica esto significa métodos normalizados que hacen comparables los datos entre laboratorios, lo que redujo la carga del equipo de mantenimiento.